请使用支持JavaScript的浏览器! GenWay/Mouse SAP (Serum Amyloid P) ELISA Kit/GWB-B2F5E0/96 well-蚂蚁淘商城
新闻动态

GenWay/Mouse SAP (Serum Amyloid P) ELISA Kit/GWB-B2F5E0/96 well

  
  2024-04-29
  

Description:

Short Description: In this assay the SAP present in serum sample reacts with the anti-SAP. antibodies which have been adsorbed to the surface of polystyrene microtitre wells. After the removal of unbound serum proteins by washing, anti-SAP. antibodies conjugated with horseradish peroxidase (HRP), are added. These enzyme-labeled antibodies form complexes with the previously bound serum SAP. Following another washing step, the enzyme bound to the immunosorbent is assayed by the addition of a chromogenic substrate, 3,3’,5,5’- tetramethylbenzidine (TMB). The quantity of bound enzyme varies directly with the concentration of SAP in the sample tested; thus, the absorbance, at 450 nm, is a measure of the concentration of SAP in the test sample. The quantity of SAP in the test sample can be interpolated from the standard curve constructed from the standards, and corrected for serum dilution.

Additional Information:

Name Related Product Names Gene Symbol Gene Fullname Gene id Alias Symbols Protein Name Swissprot ID Species Reactivity Assay Info Sensitivity Kit Range Homology NCBI Acc Number Standard Range Sample Type Product Format Specimen/Volumes Swiss Prot Number Applications Reconstitution and Storage Reactivity Kit Size Kit Principle Kit Component Kit Duration Storage Lead Time Intended Use Additional Information ::
Mouse SAP (Serum Amyloid P) ELISA Kit
Mouse SAP (Serum Amyloid P) ELISA Kit; SAP; 9.5S alpha-1-glycoprotein PTX2Mouse SAP (Serum Amyloid P)SAP
APCS
serum amyloid P-component
20219
serum amyloid P, SAP
Serum amyloid P-component
P12246
Mouse
Assay Methodology: Quantitative Sandwich ELISA
1.845 ng/ml
6.25 ng/ml - 200 ng/ml
Mouse
NP_001630.1
Refer To Manual
Serum, plasma and other biological fluids
In Solution
Refer To Manual
P02743
ELISA
1. DILUENTThe 5X Diluent Concentrate is stable until the expira-tion date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions should be stored at 4-8C.2. WASH SOLUTIONThe 20X Wash Solution Concentrate is stable until the expira¬tion date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions can be stored at room temperature (16 25C) or at 4-8C.3. ENZYME-ANTIBODY CONJUGATEUndiluted horseradish peroxidase anti-SAP conjugate should be stored at 4-8C and diluted immediately prior to use. The working conjugate solution is stable for up to 8 hours.4. CHROMOGEN-SUBSTRATE SOLUTIONThe Substrate Solution should be stored at 4-8C and is stable until the expiration date.5. STOP SOLUTIONThe Stop Solution should be stored at 4-8C and is stable until the expiration date.6. ANTI-MOUSE SAP ELISA MICRO PLATEAnti-Mouse SAP coated wells are stable until the expiration date, and should be stored at 4-8C in sealed foil pouch with desiccant pack.7. MOUSE SAP CALIBRATORThe lyophilized Mouse SAP calibrator should be stored at 4C or frozen until reconstituted. The reconstituted calibrator should be aliquoted out and stored frozen (Avoid multiple freeze-thaw cycles). The working standard solutions should be prepared immediately prior to use and are stable for up to 1 hour.
Mouse
96 well
Genway Biotech SAP ELISA Kit (Mouse) (GWB-B2F5E0) is based on standard sandwich enzyme-linked immuno-sorbent assay technology. An antibody for Serum amyloid P-component has been pre-coated onto a 96-wellplate (12 x 8 Well Strips). Standards or test samples are added to the wells, incubated and washed to remove unbound proteins. An Anti-Serum amyloid P-component - HRP conjugated detector antibody is then added, incubated and unbound conjugate is washed away. An enzymatic reaction is produced through the addition of TMB substrate which is catalyzed by HRP generating a blue color product that changes to yellow after adding acidic stop solution. The density of yellow coloration read by absorbance at 450 nm is quantitatively proportional to the amount of sample Serum amyloid P-component captured in the well.
ComponentAmount
Anti-Mouse SAP Microplate96 Wells (12 x 8 Well Strips)
20X Diluent Concentrate50 mL
20X Wash Solution50 mL
100X Enzyme-Antibody Conjugate150 uL
Chromogen-Substrate Solution12 mL
Stop Solution12 mL
Mouse SAP Calibrator1
130 Minutes
Refer to kit instructions for component storage
Domestic: within 1 week deliveryInternational: 1 week
Research Use Only
Intended Use: The SAP test kits are a highly sensitive two-site enzyme linked immunoassay (ELISA) for measuring SAP in biological samples of mice.
Reagents: 1. DILUENT CONCENTRATE (Running Buffer)One bottle containing 50 ml of a 5X concentrated diluent running buffer. 2. WASH SOLUTION CONCENTRATE One bottle containing 50 ml of a 20X concentrated wash solution.3. ENZYME-ANTIBODY CONJUGATE 100XOne vial containing 150 ul of affinity purified anti-Mouse SAP antibody conjugated with horseradish peroxidase in a stabilizing buffer.4. CHROMOGEN-SUBSTRATE SOLUTIONOne vial containing 12 mL of 3,3’,5,5’-tetramethybenzidine (TMB) and hydrogen peroxide in citric acid buffer at pH 3.3.5. STOP SOLUTIONOne vial containing 12 ml 0.3 M sulfuric acid.WARNING: Avoid contact with skin.6. ANTI-MOUSE SAP ELISA MICRO PLATETwelve removable eight (8) well micro well strips in well holder frame. Each well is coated with affinity purified anti-Mouse SAP.7. MOUSE SAP CALIBRATOROne vial containing a lyophilized Mouse SAP calibrator.

本文链接: https://www.ebiomall.cn/b651-genway/info-1473284737.html

免责声明 本文仅代表作者个人观点,与本网无关。其创作性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不做任何保证或承诺,请读者仅作参考,并请自行核实相关内容。
版权声明 未经蚂蚁淘授权不得转载、摘编或利用其他方式使用上述作品。已经经本网授权使用作品的,应该授权范围内使用,并注明“来源:蚂蚁淘”。违反上述声明者,本网将追究其相关法律责任。
没有了