
Description:
DISCONTINUED–REPLACEMENT:MP0240
Multiplate®RISTOtestisaresearchreagentkitforthequantitativeinvitrodeterminationofvonWillebrandFactor(vWF)-andglycoproteinIb(GpIb)-dependentplateletaggregationstudiesontheMultiplate®analyzer.
RistocetinisanantimicrobialsubstancewhichformscomplexeswithvWF(vonWillebrandfactor).Inthiscomplex,vWFchangesitsconformationinawaythatallowsittobindtoplatelets.Thebindingofristocetin-vWFcomplexesleadstotheaggregationandactivationofplatelets.ThisactivationreliesonthebindingofvWFtotheGPIbreceptoranditisinhibitedbytheactionofAspirin®.ThisexplainstheAspirin®sensitivityofRISTOtest.CompletelackofaggregationintheresearchRISTOhightestcanbecausedbyanabsenceofGPIbreceptorsontheplateletsurface(Bernard-Souliersyndrome)orbyanabsenceofvWFinthesolution(vWDtypeIII).
KitComposition:
Reagents,StorageandStABIlity
- MP0140:Multiplate®RISTOtestReagent,Kit,Ristocetin,1x1.0mL, lyophilized(10mg/ml),with5microtesttubesfor aliquotation.UnopenedvialsoftheRISTOtestreagentmustbestored at2-8°C.Thereagentisstableuntiltheexpirydate printedontheviallabelwhenstoredunderthese conditions.Ifreconstitutedreagentisnotaliquotedinto microtesttubes,theoriginalvialshouldbestoredinan uprightposition. Stable7daysafterreconstitutionwhenstoredat 2-8°C, 4weeks at<-20°Cor24hoursatroomtemperatureafterone timethawing.
AlsoAvailable
- MP0094: Multiplate®RISTOtestAliquotVials,Bag, 100microtubescolorcoded(blue)forfor aliquotation.
- MP0194:Multiplate®RISTOtestReagent,Bag, Ristocetin,1x1.0mL, lyophilized(10mg/ml),withoutmicrotesttubesfor aliquotation.
- MP0240:Multiplate®RISTOtestReagent,Kit,Ristocetin,3x1.0mL, lyophilized(10mg/mL),withoutmicrotesttubesfor aliquotation.
MeasurementPrinciple:
RISTOtestreagentcontainsristocetin.Ristocetinformsa complexwithvWFfromthesample.Thiscomplexbinds totheplateletGpIbreceptorandtriggersplatelet activationandaggregation.RISTOtestcanbeappliedin twoconcentrations:InRISTOhightestahigh concentrationofristocetin(0.77mg/mL)isapplied,which normallyinducesastrongplateletaggregation.Abolished aggregationinRISTOhightestcanbebasedona deficiencyofGpIbreceptorsorvWF.InRISTOlowtesta lowerconcentrationofristocetin(0.2mg/mL)isapplied whichnormallydoesnotinduceastrongaggregation response.Ahigherthanexpectedaggregationin RISTOlowtestmayindicateanenhancedaggregation tendencyofvWF(vWDtypeIIb).
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
最近要添加一些设备,请教各位大神推荐的厂家及其型号。
需要的设备如下:高速剪切混合机、湿法制粒机、干法制粒机、整粒机、包衣机、胶囊填充机、铝塑包装机。
先谢谢各位大神了
比较电泳设备.pdf(425.0k)
(y)战友资源。萝卜茄子都是好美味。
常用制药设备1.rar(232.25k)
常用制药设备的PPT(带彩图).rar(751.71k)
要是能上传一些真实药厂设备,也许对大家都有帮助。
下面上传《常用制剂设备》的图扫描。
http://www.k65.net/mail/url.php?n=eXpmMzcyMT0v
code:37217613

