- YO-01027 (Dibenzazepine, DBZ)
- DAPT (GSI-IX)
- JLK 6
- BMS-708163 (Avagacestat)
- MK-0752
- MRK 560
(±)-Myristoylcarnitine chloridecholinergic agonist; important intermediates in lipid metabolism |
Sample solution is provided at 25 µL, 10mM.
































Quality Control & MSDS
- View current batch:
- Purity = 98.00%
- COA (Certificate Of Analysis)
- MSDS (Material Safety Data Sheet)
Chemical structure


(±)-Myristoylcarnitine chloride Dilution Calculator
calculate

(±)-Myristoylcarnitine chloride Molarity Calculator
calculate
Cas No. | 14919-38-1 | SDF | Download SDF |
Synonyms | N/A | ||
Chemical Name | (R)-3-carboxy-N,N,N-trimethyl-2-(tetradecanoyloxy)propan-1-aminium chloride | ||
Canonical SMILES | O=C(CCCCCCCCCCCCC)O[C@H](CC(O)=O)C[N+](C)(C)C.[Cl-] | ||
Formula | C21H42ClNO4 | M.Wt | 408.02 |
Solubility | <10.2mg l="" in="" h2o="">10.2mg> | Storage | Store at -20°C |
Physical Appearance | White solid | Shipping Condition | Evaluation sample solution : ship with blue ice.All other available size:ship with RT , or blue ice upon request |
General tips | For obtaining a higher solubility , please warm the tube at 37 ℃ and shake it in the ultrasonic bath for a while.Stock solution can be stored below -20℃ for several months. |
(±)-Myristoylcarnitine chloride is an agonist for cholinergic and a homolog of acetylcarnitine chloride (Cat No. B6273).
Acetylcholine receptor (AChR) is an integral membrane protein receptor for acetylcholine. There are two kinds of AChRs: nicotinic acetylcholine receptors and muscarinic acetylcholine receptors.
(±)-Myristoylcarnitine chloride is a cholinergic agonist and an intermediate in lipid metabolism [1]. In retinal ganglion cells, acetylcarnitine and acetylcholine inhibited GABAergic responses to exogenous GABA and GABAergic inhibitory postsynaptic currents [2].
In dogs with coronary ligation, (-)-carnitine chloride (LCC) (300 mg/kg) and acetyl (-)-carnitine chloride (ALCC) (300 mg/kg) inhibited the ventricular arrhythmia. Also, LCC and ALCC improved oxidative phosphorylation rate and the mitochondrial function [1]. In the mouse hot plate test, acetyl-l-carnitine (ALCAR) (100 mg/kg) exhibited analgesia. While, U-73122 and neomycin (the phospholipase C (PLC) inhibitors) blocked the increase of the pain threshold induced by ALCAR. LiCl that impairing phosphatidylinositol synthesis antagonized the antinociception in a dose-dependent way. PMA and PDBu (PKC activators) blocked the increase of the pain threshold in a dose-dependent way. These results suggested that ALCAR analgesia required the participation of the PLC-IP3 pathway [3].
References:[1]. Imai S, Matsui K, Nakazawa M, et al. Anti-arrhythmic effects of (-)-carnitine chloride and its acetyl analogue on canine late ventricular arrhythmia induced by ligation of the coronary artery as related to improvement of mitochondrial function. Br J Pharmacol, 1984, 82(2): 533-542.[2]. B?hring R, Standhardt H, Martelli EA, et al. GABA-activated chloride currents of postnatal mouse retinal ganglion cells are blocked by acetylcholine and acetylcarnitine: how specific are ion channels in immature neurons? Eur J Neurosci, 1994, 6(7): 1089-1099.[3]. Galeotti N, Bartolini A, Calvani M, et al. Acetyl-L-carnitine requires phospholipase C-IP3 pathway activation to induce antinociception. Neuropharmacology, 2004, 47(2): 286-294.
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
然后往容器中滴液体直至读数为0.70时就可以了
我们每天长时间都在实验室里和移液器(俗称“枪”)打交道,枪已经成为实验室标配,因为它是很多实验过程和分析的基础。但正因为如此,我们都认为它很简单,就像走路和呼吸一样自然,不需要你花任何心思,它就可以做你想做的事情。但事实真的是这样吗?
事实上,枪虽小但往往关系到实验结果的准确性,有小伙伴经常抱怨枪老出问题:
1.用了一段时间就不准漏液了?
2.液体容易倒吸?
3.移液排不干净?……
到底是哪里出问题了呢,你有没有碰到这样的迷之困惑?
当当当,福利到,来自梅特勒-托利多瑞宁移液技术专家自告奋勇来解答大伙儿的困惑,有任何关于移液器使用的问题欢迎来和我们探讨共同进步哟~
最后感谢丁香园支持本活动!
我们会每天抽时间统一回复大家的问题,专家答疑截止12月31日哦!
塑料类工具灭菌有什么需要注意的吗?谢谢!
2、吸液:用右手的拇指和中指捏住移液管的上端,将管的下口插入欲吸取的溶液中,插入
不要太浅或太深,一般为10~20mm处,太浅会产生吸空,把溶液吸到洗耳球内弄脏溶液,
太深又会在管外沾附溶液过多。左手拿洗耳球,接在管的上口把溶液慢慢吸入,先吸入该管 容量的1/3
左右,用右手的食指按住管口,取出,横持,并转动管子使溶液接触到刻度以上 部位,以置换内壁的水分,然后将溶液从管的下口放出并弃去,如此用反复洗3
次后,即可 吸取溶液至刻度以上,立即用右手的食指按住管口。 3、调节液面:将移液管向上提升离开液面,管的末端仍靠在盛溶液器皿的内壁上,管身保
持直立,略为放松食指(有时可微微转动吸管)使管内溶液慢慢从下口流出,直至溶液的弯
月面底部与标线相切为止,立即用食指压紧管口。将尖端的液滴靠壁去掉,移出移液管,插 入承接溶液的器皿中。
4、放出溶液:承接溶液的器皿如是锥形瓶,应使锥形瓶倾斜30°,移液管直立,管下端紧
靠锥形瓶内壁,稍松开食指,让溶液沿瓶壁慢慢流下,流完后管尖端接触瓶内壁约15 秒后,
再将移液管移去,残留在管末端的少量溶液,不可用外力强使其流出,因较准时已考虑了末 端保留的溶液的体积。
大家做溶出曲线稀释溶液时有某有再用移液枪?移液枪量取1ml的体积准确不?