REF14093
Incubatorwithaninnervolumeof60liters
AdvantagesofC60:
- Activesterilehumidity:
- CO2sensor:
- Directheating:
- Optional:
Externalwaterreservoir
Relativehumidityvaporizedat120°C
Minimizedriskofcontamination
Humiditysensor(rH)
Veryshortrecoverytimes
Dualbeaminfraredsensor
Veryprecisemeasurement
Veryshortrecoverytimes
Long-termstable
Independentover-allheatingofinnerwallsanddoor
Homogeneoustemperaturedistributionintheinterior
Veryshortrecoverytimes
C60_english_10_072017.pdf

- Features
- Technicaldata
- Options
Interior | Electro-polishedstainlesssteelwithcovedcorners Shelvesandductworkeasilyremovableforcleaningpurpose |
Temperature | Panelheatedinteriorchamberanddoor Intelligenttemperaturecontrolsystemfordryinnerchamber |
ActivesterileHumiditysupply | Externalwatersupplycontainer |
CO2control | Dualbeaminfraredsensor Measurementindependentfromtemperatureandhumidity |
Shortrecoverytimes | Foralladjustableparametersthroughoptimizedmicroprocessorcontrol |
Easyhandling | Menuguided Large,backlitLCD |
Diagnosticsystem | Opticalandacousticalarmifsetpointdeviationorsensordefectoccurs Doormonitoring Remotealarm |
Options | O2control:connectionforN2possIBLe Subdividedinnerglassdoorwith4 smalldoors Lockablefrontdoor |
Interfaces | Alarmcontact(potentialfree) RS485interfaceforconnectionofoptionalavailablePCsoftwareLaboDat+ |
Exterior | Dimensions510x540x720 mm(w x d x h) |
Interior | Volume60 l Electro-polishedstainlesssteel 3Shelves,heightadjustable |
Temperature | Panelheatedinteriorchamberanddoor Range27 °C-42 °Cstarting5 °Caboveambienttemperature StABIlity/uniformity± 0.1 °C / ± 0.3 °C Over-temperaturealarm32 °C-47 °C |
CO2control | Dualbeaminfraredsensor Range0–10 % CO2 Stability± 0.1 % CO2 |
O2control<21 %(optional) | Measurementwithgalvanicsensor ConnectionofN2 Range1 % – 21 % O2 |
Humidity | Activesterilehumiditysupplythroughvaporizingmoduleoperatingat120 °C Measuringrange0–98 %rH/range60 % – 95 %rH |
Supply | 230VAC,50/60 Hzor115 V AC,50/60 Hz,160W Inletpressureforgas0.8 bar Ambienttemperature18 °C-30 °C |
Classification | SafetyclassI EN61010conform |
![]() | Subdividedinnerglassdoor-forbetterrecoverytimes
Subdividedinnerglassdoorwith4smalldoors Lowergasconsumption
|
![]() | Stackingkit-forsafepositioning Safe,easyandspace-savingpositioningofthedevicesinthelaboratory
|
![]() | Lockablefrontdoor-highersecurityforyourcultures |
OurincubatorC60isavailablewithO2controlasoption(O2<21 %) | |
FurtheraccessoriesforincubatorC60 | Incubator-Filter-Box GasIn-Line-Filter Accessoriesforactivesterilehumiditysupply PCsoftwareLaboDat+ |
ebiomall.com






>
>
>
>
>
>
>
>
>
>
使用培养箱需注意的:
1、电池指示器批示电能耗尽时,不要使用仪器。若长时间不使用仪器,请将电池取出后存放。
2、不要在高温、高湿、易燃、易爆和强电磁场环境中存放或者使用本仪器。
3、使用湿布或者清洁剂来清洗仪器外壳,勿使用磨擦物或溶剂。
4、仪器潮湿时,先干燥后存放。
过完年,再开培养箱参数不稳定,两个箱子,co2数值一直在闪~我要养细胞,参数设置的是37℃,5%CO2,请问各位大神有知道咋回事的~还有面板上各种符号啥意思?图中标记的都是在闪的参数
二、二类医疗器械若是经营的话,要到当地药监局备案
第二类医疗器械经营备案
(一)自2014年6月1日起,从事第二类医疗器械经营的,经营企业应填写第二类医疗器械经营备案表(见附件4),向所在地设区的市级食品药品监督管理部门备案,并提交符合第二类医疗器械经营备案材料要求(见附件5)的备案材料。
接收医疗器械经营备案材料的设区的市级食品药品监督管理部门应当场对备案材料完整性进行核对,符合规定条件的予以备案,发给第二类医疗器械经营备案凭证(见附件6)。
第二类医疗器械经营备案凭证的备案号编号规则为:XX食药监械经营备XXXXXXXX号。其中:第一位X代表备案部门所在地省、自治区、直辖市的中文简称,第二位X代表所在地设区的市级行政区域的中文简称,第三到六位X代表4位数备案年份,第七到十位X代表4位数备案流水号。
三、你的问题不是很具体,可以到贴吧交流http://tieba.baidu.com/p/4535310200
我们两种培养箱都用过,都选择的是上海喆图的,我们去过他们工厂实地考察,他们是专业生产培养箱的,其中就有电热恒温培养箱和隔水式恒温培养箱。


暂无品牌分类