REF16377
BenchtopincubatorwithintegratedSAFESens®technologyforcontinuous,non-invasivepHmonitoring
AdvantagesofLaboC-TopwithSAFESens®pHmonitoring:
- AlladvantagesandoptionsofLaboC-Topcombinedwithstate-of-the-artpHmonitoringsystem
- IndependentmonitoringofthepH-valueinC-Topchambers
- TrakPods™integratedinsurfaceofLaboC-Topwithoutuseofvaluabledishspace
- RealtimemonitoringofthepH-valueeveryminuteorevery30minutesforupto7days
- Accuratemeasurements:±0.05inarangeofpH7.00to7.60
- SAFESens®measurementtechnologyutilizesapatentedandprovenLED-basedopticalfluorescentsystem
- IncludedSoftwarefordatarecordingcapABIlitiesandautomaticalerts(bye-mail)
- Monitoringofupto8chamberswithoneTrakStation™
C-Top_SafeSens_english_0_022017.pdf
- Features
- Technicaldata
- Options
pHvalue | Accuratemeasurements:±0.05inarangeofpH7.00to7.60 ChangesofpHimmediatelyvisIBLeduetocontinuousmonitoring |
Non-invasive | Nopetri-dishrequired Monitoringwithoutstaffinterventionandlidopening |
Calibration | Nocostly,timeconsumingcalibrationrequired:
|
Options | IntegratedSAFESens®TrakPod™eitheronbothsidesorsideofchoice WithorwithoutSAFESens®TrakStation™ PCsoftwareLaboDat+fordocumentationofincubator’sparameters |
Interfaces | Remotealarm(potentialfree) RS485-interfacefordataloggingwithoptionalavailablePCsoftwareLaboDat+ |
Exterior | Dimensions403x225x155mm(wxdxh) Weight8.8kg |
Interior | Twochamberswith0.5literseach Mixedloadpossible |
Temperature | Overallheatingfromtopandbottomofeachchamber Range30°C-42°Cfrom7°Cabove ambienttemperature Stability/uniformity± 0.1 °C/± 0.3 °C |
Gassing | Premixedgas Gasflowadjustablebetween20ml/minand30ml/min Flowrateafteropeningthelid(automaticgaspurge): 250ml/minfor3minutes |
PowerSupply | 110–230VAC,50/60Hz,100VA Primarypressureforgas0.8bar Ambienttemperature18°C-30°C |
Classification | SafetyclassI ClassIIaforeveryusageaccordingtoEC-Directive93/42/EEC EN61010conform |
![]() | REF16377 LaboC-TopwithSAFESens®pHmonitoringsystem
|
![]() | REF16374 SAFESens®TrakStation™ |
![]() | REF16370 SAFESens®sterilesv2-sensor |
![]() | REF16371 SAFESens®qc2alignmenttool |
![]() | LaboC-TopwithSAFESens®pHmonitoringandlockablelids Limitedaccesstothecultures
|
![]() | LaboC-TopwithSAFESens®pHmonitoringandsecondgasinlet
Everychambertobegassedwithdifferentmixturesatthesametime |
FurtheraccessoriesforLaboC-Top | LaboGasMixer |
TheSAFESens®pH-monitoringsystemisalsoavailableforlargeformatincubators |
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
光照培养箱具有超温和传感器异常保护功能,保障仪器和样品安全;选配全光谱的植物生长灯,有利于植物的生长,提高抗病性。具有掉电记忆、掉电时间自动补偿功能;恒温控制系统,反应快,控温精度高。 用途:微电脑全自动控制,触摸开关,操作简便;可编程多段控制方式,白天、黑夜均可单独设置温度、湿度、光照度和时间等。风道式通风,工作室风速柔和,温度均匀;中空反射钢化渡膜玻璃,绝热性能好,美观大方。全封闭不透光灯罩,选装工作室电源,消毒装置等。我们购买的是喆图的光照培养箱,服务质量都不错,推荐下
具体可以查看一下说明书。
2. 我的经验是在补充水时最好把水加热一下,达到培养箱的温度。
3. 这么早就养细胞了,我们这里一般是用70%的乙醇擦洗,然后再用0.1%的新洁尔灭擦洗,不放心的话再用高锰酸钾加甲醛1:1比例熏一遍。注意要是熏的话千万注意混合之后马上离开,然后密闭细胞培养室,味道很刺激的。最好在养细胞前消毒,否则,确实没地方放细胞。
4. 我们的方法比较简单,先用75%酒精擦拭内壁,通风10分钟,紫外线照射30分钟即可。
5. 我们的通常处理是先用75%的酒精擦拭内壁,然后用甲醛+高锰酸钾熏蒸一个晚上,然后通风一整天(同时打开紫外线照射)。
6. 我们是把培养箱里的板层拿出来高压一下,箱壁用75%酒精擦一遍,换用诗乐氏擦一遍,再紫外照一夜,效果很好,其他的请高手指教。
7. 熏蒸后吹一天是绝对不够的,最起码要一个星期才可以让甲醛散尽,要不细胞长不好的
8. 有的培养箱能加热内壁到90度,也有的带有紫外线功能。常规应该每周用酒精擦洗内部一次。具体的操作请参考培养箱的手册,或着咨询培养箱技术支持。使用消毒剂应小心,培养箱内有检测温度、湿度和二氧化碳浓度的传感器,腐蚀性消毒剂或有机溶剂有可能损坏某些器件,请慎用。另外,挥发性的甲醛有毒,易燃、易爆。如果在培养箱内残留甲醛的话,细胞会死光光哦(我实验室的真实故事)。总之,先看培养箱手册,再联系技术支持,方可万无一失啊。
9. 常规最好什么也不放!硫酸铜的作用是抑制细菌生长(但多数用在处理污染的孔板)。因为现在的孵箱都有抑菌功能。
10. 我们实验室的做法:把平皿高压灭菌后,在无菌操作台内加入适量的灭菌双蒸水或者生理盐水.再加少量新洁尔灭,浓度没关系.细胞养的都可以.
现在国产二氧化碳培养箱质量怎么样啊?
干燥箱可分为普通式和鼓风式两种。后者在箱内装有一个风机,用以加快热空气的对流,使箱内温度均匀。同时使箱内物品蒸发的水蒸气加速散发到箱外的空气中,以提高干燥效率。
培养箱主要有直热式和隔水式两种:直热式用电热丝直接加热。隔水式培养箱的恒温室被水箱包围,通电后,加热的是水,利用热水的温度使箱内恒温,故为间接加热。这种培养箱温度的上升或下降较为缓慢,更适合于细菌培养箱。