- Description
- Additional
Description
Details
Description:Mouse monoclonal antibody to human S100A7 (psoriasin)
Purification:Protein G affinity purified
Product Type: Primary antibody
Target Protein:Human S100A7 (psoriasin)
Immunogen:A short peptide (tdyhkqshgaapcsggs) derived from human S100A7 (psoriasin) was conjugated with KLH for immunization.
Fusion Myeloma:Sp2/0-Ag14
Specificity:This antibody is reactive to S100A7 peptide (tdyhkqshgaapcsggs) and GST tagged recombinant S100A7 protein.
Species Reacitvity:Human, others not tested
Host / Isotype:Mouse, IgG1 Kappa
Formulation:Lyophilized from a solution in 0.01M PBS, pH 7.0
Reconstitution:Double distilled water is recommended to adjust the final concentration to 1.00mg/mL.
Storage: Store at -20oC
Research Area:Oncology, psoriasis
Background:
S100A7 is 11 kilo-dalton calcium binding protein with 2 EF motifs. It is also called psoriasin due to its significantly elevated level in the skin lesion of psoriasis. The protein is over-expressed in squamous cell tumors of the skin, lung and breast. S100A7 expression is induced after activation of epidermal growth factor receptor.
Application:
Western blot (see image): This antibody is reactive to 36.85KD GST tagged recombinant S100A7 protein.
The GST tagged recombinant S100A7 was loaded at 200ng/lane. The anti- S100A7 clone 9A4 was used at 1μg/ml, and the HRP conjugated goat anti-mouse IgG was used at 1:2,000 dilution.
ELISA:This antibody is reactive to recombinant S100A7 protein.
References:
If research is published using this product, please inform Anogen in order to cite the reference on this datasheet. Anogen will provide one unit of product in the same category as gratitude.
Additional
Additional Information
Product Specificity | mAb anti-Human S100A7 (psoriasin), 9A4 |
---|---|
Application | WB, EIA |
Size | 0.1 mg |
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
酶标仪按照功能的不同划分,可以分为(1)光吸收酶标仪(可见酶标仪,紫外/可见酶标仪)(2)荧光酶标仪(3)化学发光酶标仪。
分光光度计按照波长及应用领域的不同可以分为:(1)可见光分光光度计(2)紫外分光光度计(3)红外分光光度计(4)荧光分光光度计(5)原子吸收分光光度计。
分光光度计和酶标板存在一些不同之处,具体差别体现在以下三个方面:
(1)盛装待测溶液的容器:
分光光度计用的是比色皿,酶标仪使用的是塑料微孔板(酶标板)。比色皿只能起到盛装溶液的作用,每个比色皿一次只能盛装一种溶液。酶标板常用透明的聚乙烯材料制成,对抗原抗体有较强的吸附作用,因此用它作为固相载体,酶标板通常为48孔或96孔,每个微孔可以盛装不同的溶液。
(2)光路的方向:
分光光度计是水平光路,而酶标仪则是垂直光路。由于酶标板盛样本的塑料微孔板是多排多孔的,光线只能垂直穿过,因此酶标仪的光束都是垂直通过待测溶液和微孔板的,光束既可是从上到下,也可以是从下到上穿过比色液。垂直光的特点是标本吸光度受液体浓缩或稀释的影响小,不足之处是受被测样本液面是否水平、酶标板透光性、孔底是否平整等的影响较大。
(3)光路的长度:
由于光密度(OD值)与吸光系数, 待测组分的浓度以及光路长度成正比关系。
分光光度计采用的比色杯的宽度通常是1cm,所以光路长度固定为1cm。因此不同仪器,不同批次测量的数据具有同样的可比性。
而酶标仪采用的是垂直光路, 所以光路的长度应该是液体液面的高度。所以测得的值受到样品的体积的影响。
请问BAC蛋白浓度测定波长是562,我们这边酶标仪的滤光片波长最接近的是595,这样也可以测吗
各位前辈,MTT法加样后第一天阳性组镜下看细胞全死了,样品组和阴性组镜下状态还可以,加DMSO后样品孔和阴性孔颜色粉红,阳性孔红紫到发黑,酶标仪检测,样品组和阴性组大概0.2-0.4,阳性组却有1.2-1.4,请问,这是怎么回事?细胞接板密度为4*104,100μL。向各位求助了,万分感谢!