Antibody Pair for Vascular Endothelial Growth Factor A (VEGFA)
VEGF; VEGF-A; VPF; Vascular Endothelial Cell Growth Factor A; Vascular Permeability Factor
- Product No.PSA143Hu01
- Organism SpeciesHomo sapiens (Human) Same name, Different species.
- All
- Human
- Mouse
- Rat
- Cavia
- Rabbit
- Simian
- Caprine
- Ovine
- Equine
- Bovine
- Porcine
- Gallus
- Canine
- Others
- Multi-species
- Pan-species
- Reagent Contents
Recombinant Vascular Endothelial Growth Factor A (VEGFA) 10ug Standard Monoclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) 500ug Capture Ab Biotin-Linked Monoclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) 50ug Detection Ab - ApplicationsELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays.
- Downloadn/a
- FOBUS$ 907 For more details, please contact local distributors!US$ 1512 For more details, please contact local distributors!US$ 2722 For more details, please contact local distributors!US$ 5292 For more details, please contact local distributors!US$ 9072 For more details, please contact local distributors!
MATCHING TESTS of the Antibody Pair for Vascular Endothelial Growth Factor A (VEGFA)
USAGE of the Antibody Pair for Vascular Endothelial Growth Factor A (VEGFA)
The concentration of protein/peptide and antibodies used in different immunoassays need to be determined by users according to their experiments.
STORAGE of the Antibody Pair for Vascular Endothelial Growth Factor A (VEGFA)
Avoid repeated freeze/thaw cycles. Store at 2-8°C for one month. Aliquot and store at -80°C for 12 months.
STABILITY of the Antibody Pair for Vascular Endothelial Growth Factor A (VEGFA)
The thermal stability is described by the loss rate. The loss rate was determined by accelerated thermal degradation test, that is, incubate the protein at 37°C for 48h, and no obvious degradation and precipitation were observed. The loss rate is less than 5% within the expiration date under appropriate storage condition.
GIVEAWAYS
ELISA / CLIA Experiment Service
INCREMENT SERVICES
CLIA Kit Customized ServiceELISA Kit Customized ServiceStandard DiluentCoating BufferDiluent Buffer for AntibodyAntibody Pairs Support Pack 1Antibody Pairs Support Pack 2Real Time PCR Experimental Service
Related products
| Catalog No. | Organism species: Homo sapiens (Human) | Applications (RESEARCH USE ONLY!) |
| RPA143Hu01 | Recombinant Vascular Endothelial Growth Factor A (VEGFA) | Positive Control; Immunogen; SDS-PAGE; WB. |
| APA143Hu01 | Active Vascular Endothelial Growth Factor A (VEGFA) | Cell culture; Activity Assays. |
| PAA143Hu01 | Polyclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) | WB; IHC; ICC; IP. |
| LAA143Hu71 | Biotin-Linked Polyclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) | WB; IHC; ICC. |
| LAA143Hu81 | FITC-Linked Polyclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) | WB; IHC; ICC; IF. |
| MAA143Hu24 | Monoclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) | WB; IHC; ICC; IP. |
| MAA143Hu26 | Monoclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) | WB; IHC; ICC; IP. |
| MAA143Hu21 | Monoclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) | WB; IHC; ICC; IP. |
| LAA143Hu76 | Biotin-Linked Monoclonal Antibody to Vascular Endothelial Growth Factor A (VEGFA) | WB; IHC; ICC. |
| HEA143Hu | High Sensitive ELISA Kit for Vascular Endothelial Growth Factor A (VEGFA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SEA143Hu | ELISA Kit for Vascular Endothelial Growth Factor A (VEGFA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| MEA143Hu | Mini Samples ELISA Kit for Vascular Endothelial Growth Factor A (VEGFA) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCA143Hu | CLIA Kit for Vascular Endothelial Growth Factor A (VEGFA) | Chemiluminescent immunoassay for Antigen Detection. |
| PSA143Hu01 | Antibody Pair for Vascular Endothelial Growth Factor A (VEGFA) | ELISA; CLIA; ELISPOT; Luminex; Immunochromatography and other Immunoassays. |
| KSA143Hu01 | ELISA Kit DIY Materials for Vascular Endothelial Growth Factor A (VEGFA) | Main materials for "Do It (ELISA Kit) Yourself". |
ebiomall.com
>
>
>
>
>
>
>
>
>
>
>
>
标准曲线是直接用标准溶液制作的曲线,是用来描述被测物质的浓度(或含量)在分析仪器响应信号值之间定量关系的曲线。在分光光度法分析中,被测物质的浓度在仪器上的响应信号值在一定范围内呈直线关系,水样测定的结果可以从标准曲线上查出。因此标准曲线制作的好坏,将会影响测定结果的准确度。1标准曲线的表达式标准曲线应是一条通过原点的直线,如果坐标上各浓度点基本在一条直线上可不进行回归处理,但在实验中不可避免地存在测定误差,往往会有一、二点偏离直线,此时可用最小二乘法进行回归分析,然后绘制曲线,通常称为回归直线,而代表回归直线方程叫回归方程,表达式为:y=bx+a(式中:b为直线斜率,a为y轴上的截距,x为被测溶液的浓度,y为吸光度,是多次测定结果的平均值)。在实际工作中,制作标准曲线的目的,是要借助它来查出水样中被测物质的浓度,而不是由x值通过回归方程去求得最可靠的y值,为了便于将观察到仪器响应信号值代入回归方程中直接计算试样的浓度或含量,勿需去绘制标准曲线再从曲线上查出被测物的浓度,改用下式计算;x=by+a(式中:a为x轴线上的截距,其它解释同前)。2标准曲线的参数标准曲线有3个参数,即相关系数r,斜率b
绘制标准曲线的意义
以某一特定波长条件下由分光光度计分别测出一系列不同溶度标准溶液然的吸光度值,以吸光光度值为纵坐标,相应的溶液浓度为横坐标,在坐标纸上可作出一条吸光度与浓度成正比通过原点的直线,称作标准曲线。~~~绘制标准曲线的实用意义就是只要测得其吸光度值即可在标准曲线上查出相应的浓度值。。展开
长(频率、或波数),分别测定后,手工绘制光谱图.显然这种仪器对于需要经常根据光谱图定性分析的用户而言是很不方便的,但价格相对于光谱仪要便宜得多,
对只需定量分析的用户就够用了.
1、光谱仪,以光电倍增管等光探测器测量谱线不同波长位置强度的装置。其构造由一个入射狭缝,一个色散系统,一个成像系统和一个或多个出射狭缝组成。以色散元件将辐射源的电磁辐射分离出所需要的波长或波长区域,并在选定的波长上(或扫描某一波段)进行强度测定。分为单色仪和多色仪两种。
2、分光光度计是将成分复杂的光,分解为光谱线的科学仪器。测量范围一般包括波长范围为380~780
nm的可见光区和波长范围为200~380
nm的紫外光区。不同的光源都有其特有的发射光谱,因此可采用不同的发光体作为仪器的光源。钨灯的发射光谱:钨灯光源所发出的380~780nm波长的光
谱光通过三棱镜折射后,可得到由红、橙、黄、绿、蓝、靛、紫组成的连续色谱;该色谱可作为可见光分光光度计的光源。
(1)【诺顶仪器】为了防止光电管疲劳,不测定时必须将试样室盖打开,使光路切断,以延长光电管的使用寿命。
(2)取拿比色皿时,手指只能捏住比色皿的毛玻璃面,而不能碰比色皿的光学表面。
(3)比色皿不能用碱溶液或氧化性强的洗涤液洗涤,也不能用毛刷清洗。比色皿外壁附着的水或溶液应用擦镜纸或细而软的吸水纸吸干,不要擦拭,以免损伤它的光学表面。
1.接通电源,打开仪器开关,掀开样品室暗箱盖,预热10分钟。
2.将灵敏度开关调至“1”档(若零点调节器调不到“0”时,需选用较高档。)
3.根据所需波长转动波长选择钮。
4.将空白液及测定液分别倒入比色杯3/4处,用擦镜纸擦清外壁,放入样品室内,使空白管对准光路。
5.在暗箱盖开启状态下调节零点调节器,使读数盘指针指向T=0处。
6.盖上暗箱盖,调节“100”调节器,使空白管的T=100,指针稳定后逐步拉出样品滑竿,分别读出测定管的光密度值,并记录。
7.比色完毕,关上电源,取出比色皿洗净,样品室用软布或软纸擦净。
注意事项:
1、该仪器应放在干燥的房间内,使用时放置在坚固平稳的工作台上,室内照明不宜太强。热天时不能用电扇直接向仪器吹风,防止灯泡灯丝发亮不稳定。
2、使用本仪器前,使用者应该首先了解本仪器的结构和工作原理,以及各个操纵旋钮之功能。在未按通电源之前,应该对仪器的安全性能进行检查,电源接线应牢固,通电也要良好,各个调节旋钮的起始位置应该正确,然后再按通电源开关。
3、在仪器尚未接通电源时,电表指针必须于“0”刻线上,若不是这种情况,则可以用电表上的校正螺丝进行调节。
1,被测液浓度过高造成透过样品的光信号检测不到,这种情况下可以通过稀释样品来完成;
2,测定时,样品室内的样品架在移动时没移动到位造成挡光;
3,仪器内部的光源不亮或光源没有进入单色器中。可以对照以上情况检查分析!
红外光谱仪是利用物质对不同波长的红外辐射的吸收特性,进行分子结构和化学组成分析的仪器。红外光谱仪通常由光源,单色器,探测器和计算机处理信息系统组成。根据分光装置的不同,分为色散型和干涉型。对色散型双光路光学零位平衡红外分光光度计而言,当样品吸收了一定频率的红外辐射后,分子的振动能级发生跃迁,透过的光束中相应频率的光被减弱,造成参比光路与样品光路相应辐射的强度差,从而得到所测样品的红外光谱。红外光谱仪特点 1、 只需三个分束器即可覆盖从紫外到远红外的区段;
2、 专利干涉仪,连续动态调整,稳定性极高;
3、 可实现LC/FTIR、TGA/FTIR、GC/FTIR等技术联用;
4、 智能附件即插即用,自动识别,仪器参数自动调整;
5、 光学台一体化设计,主部件对针定位,无需调整。
红外分光光度计 由光源发出的光,被分为能量均等对称的两束,一束为样品光通过样品,另一束为参考光作为基准。这两束光通过样品室进入光度计后,被扇形镜以一定的频率所调制,形成交变。基本工作原理 用一定频率的红外线聚焦照射被分析的试样,如果分子中某个基团的振动频率与照射红外线相同就会产生共振,这个基团就吸收一定频率的红外线,把分子吸收的红外线的情况用仪器记录下来,便能得到全面反映试样成份特征的光谱,从而推测化合物的类型和结构。IR光谱主要是定性技术,但是随着比例记录电子装置的出现,也能迅速而准确地进行定量分析。
特点
一般的红外光谱是指2.5-50微米(对应波数4000--200厘米-1)之间的中红外光谱,这是研究研究有机化合物最常用的光谱区域。红外光谱法的特点是:快速、样品量少(几微克-几毫克),特征性强(各种物质有其特定的红外光谱图)、能分析各种状态(气、液、固)的试样以及不破坏样品。红外光谱仪是化学、物理、地质、生物、医学、纺织、环保及材料科学等的重要研究工具和测试手段,而远红光谱更是研究金属配位化合物的重要手段。