Human CD154 (CD40 Ligand) is a member of the tumor necrosis factor (TNF) family and is expressed on the surface of activated T cells. Interaction of CD154 and CD40 is essential for isotype switching in B cells. Known genetic defects that alter this interaction lead to impaired immune system function (1). CD154 has been shown to be hyperexpressed by B and T cells in SLE patients (4). CD154 has been reported to be expressed on vascular endothelial cells, smooth muscle cells and macrophages indicating a possible role for the CD40-CD154 immunoregulatory signaling mechanism during inflammation and immunity in atherogenesis (6).
Isotype: Murine IgG1
Immunogen: Human sgp39 fusion protein
Specificity: Antibody 24-31 immunoprecipitates a CD154 (gp39) molecule of about 39 kd. This clone has been reported to cross react with Cynomolgus and Rhesus Monkey CD154.
Functional Application: The antibody 24-31 will block MLR, sgp39 induced human B cell proliferation and T cell dependent B cell differentiation (9).
References:
1. D. Gray, et al, (1994) Seminars in Immunol 6: 303-310.
2. F. Pietravalle, et al, (1996) J Biol Chemistry 271: 5965-5967.
3. R.J. Noelle, (1996) Immunity 4: 415-419.
4. A. Desai-Mehta, et al, (1996) J Clin Invest 97: 2063-2073.
5. I.S. Grewal and R.A. Flavell, (1996) Immunol Today 17: 410-414.
6. F. Mach, et al, (1997) Proc Natl Acad Sci USA 94:1931-1936.
7. F. Pietraville, et al, (1996) Eur J. Immunol 26:725-728.
8. U.G. Wagner, C. Weyland, et al, (1998) J Immunol 161: 6390-6397.
9. M. Epeldegui, O. Martinez-Maza, et al. (2010) PLOS one 5(7): e11448. PMID: 20625427.
10. B Barnhart, L R Covey, et al. (2000) Immunology 99(1): 54-61. PMID: 10651941
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
下面是网上的操作规程
1.超净工作台操作使用前的准备工作
(1)开启超净工作台风机,净化台内环境。打开工作灯达到工作照度。
(2)检查超净工台中准备的各种灭菌饲养和实验物品是否齐全。若需更换笼盒。检查灭菌笼盒准备情况,并用不锈钢推车移至超净台移门边。
(3)检查喷雾器喷洒效果及超净台内外擦抹用的药液是否已配置好。
(4)打开房间内排风系统。排除打开笼盒时逸出的有味气体。
(5)检查IVC机组各种表头指针及目视各笼盒内的动物情况,估测IVC运行情况。
(6)记录影响实验动物繁殖、生长、发育的主要环境参数,如温度、相对湿度、日温差、笼盒内外压差等。
2.超净工作台操作使用程序及规范
(1)人员带好一次性口罩、帽子及医用乳胶手套。
(2)用双手轻轻抬起IVC笼盒外端,沿笼架搁挡向外移出笼盒,放在超净工作台旁的不锈钢小推车上。
(3)用药液喷雾器充分喷洒双手手套外表及IVC笼盒的外面,消毒灭菌并沾粘住表面的尘埃,防止进入超净台时被层流气体吹扬。也可用带手套的双手浸入药液容器中,捞起并拧干药液毛巾,擦干手套外液滴,同时擦一下笼盒的外表。
(4)打开超净工作台移门,把笼盒移入超净工作台。
(5)适当拉下超净工作台移门。打开IVC笼盒盖底之间的紧固扣并打开笼盖。侧卧放在一边。
谢谢采纳
【消过毒的无菌棉球】分几种
1、放在铁盒子里一起消过毒的
2、放在超净台上、用紫外照过30min的
急求,谢谢了!
超净工作台只能保护在工作台内操作的试剂等不受污染,并不保护工作人员,而生物安全柜是负压系统,能有效保护工作人员。
而且,紫外在培养基中造成的富氧离子会杀伤细胞。
望采纳^O^
怀着欣喜激动的心情做实验,可是。。。。。可是。。。。。超净台紫外灯忘记关了。。。。。痛心疾首,感觉不会再爱了,我连冻存都没冻过。。。。。
请各位大神指点焦虑的菜鸟,我的细胞系被照了四十多分钟,会有多大的影响,能不能继续用?对人的皮肤会不会有影响,现在过去了几个小时皮肤还挺正常的。