ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
FLT3LG; FLT3-LG; Flt3-L; FL; Fms-Related Tyrosine Kinase 3 ligand; SL cytokine
- Product No.SEA038Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- All
- Human
- Mouse
- Rat
- Cavia
- Rabbit
- Simian
- Caprine
- Ovine
- Equine
- Bovine
- Porcine
- Gallus
- Canine
- Others
- Multi-species
- Pan-species
- Test MethodDouble-antibody Sandwich
- Assay Length3h
- Detection Range0.78-50pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.33pg/mL.
- Sample TypeSerum, plasma and other biological fluids
- DownloadInstruction Manual
- UOM48T96T96T*596T*1096T*100
- FOBUS$ 319 For more details, please contact local distributors!US$ 455 For more details, please contact local distributors!US$ 2048 For more details, please contact local distributors!US$ 3868 For more details, please contact local distributors!US$ 31850 For more details, please contact local distributors!
Specificity of the ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
This assay has high sensitivity and excellent specificity for detection of FMS Like Tyrosine Kinase 3 Ligand (Flt3L).No significant cross-reactivity or interference between FMS Like Tyrosine Kinase 3 Ligand (Flt3L) and analogues was observed.
Recovery of the ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
Matrices listed below were spiked with certain level of recombinant FMS Like Tyrosine Kinase 3 Ligand (Flt3L) and the recovery rates were calculated by comparing the measured value to the expected amount of FMS Like Tyrosine Kinase 3 Ligand (Flt3L) in samples.
| Matrix | Recovery range (%) | Average(%) |
| serum(n=5) | 87-98 | 91 |
| EDTA plasma(n=5) | 98-105 | 102 |
| heparin plasma(n=5) | 87-95 | 92 |
Precision of the ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level FMS Like Tyrosine Kinase 3 Ligand (Flt3L) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level FMS Like Tyrosine Kinase 3 Ligand (Flt3L) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10%>10%>Inter-Assay: CV<12%>12%>
Linearity of the ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of FMS Like Tyrosine Kinase 3 Ligand (Flt3L) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
| Sample | 1:2 | 1:4 | 1:8 | 1:16 |
| serum(n=5) | 78-91% | 88-101% | 89-97% | 86-94% |
| EDTA plasma(n=5) | 83-95% | 92-105% | 97-104% | 80-92% |
| heparin plasma(n=5) | 90-97% | 86-94% | 89-98% | 89-103% |
Stability of the ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
1. Prepare all reagents, samples and standards;2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;4. Aspirate and wash 3 times;5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;6. Aspirate and wash 5 times;7. Add 90µL Substrate Solution. Incubate 10-20 minutes at 37°C;8. Add 50µL Stop Solution. Read at 450nm immediately.
Test principle of the ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L)
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to FMS Like Tyrosine Kinase 3 Ligand (Flt3L). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to FMS Like Tyrosine Kinase 3 Ligand (Flt3L). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain FMS Like Tyrosine Kinase 3 Ligand (Flt3L), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of FMS Like Tyrosine Kinase 3 Ligand (Flt3L) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
GIVEAWAYS
ELISA / CLIA Experiment Service
INCREMENT SERVICES
Single-component Reagents of Assay KitLysis Buffer Specific for ELISA / CLIAQuality Control of ELISA / CLIAELISA Kit Customized ServiceDisease Model Customized ServiceSerums Customized ServiceTGFB1 Activation ReagentReal Time PCR Experimental ServiceStreptavidin
Related products
| Catalog No. | Organism species: Mus musculus (Mouse) | Applications (RESEARCH USE ONLY!) |
| RPA038Mu02 | Recombinant FMS Like Tyrosine Kinase 3 Ligand (Flt3L) | Positive Control; Immunogen; SDS-PAGE; WB. |
| RPA038Mu01 | Recombinant FMS Like Tyrosine Kinase 3 Ligand (Flt3L) | Positive Control; Immunogen; SDS-PAGE; WB. |
| PAA038Mu02 | Polyclonal Antibody to FMS Like Tyrosine Kinase 3 Ligand (Flt3L) | WB; IHC; ICC; IP. |
| PAA038Mu01 | Polyclonal Antibody to FMS Like Tyrosine Kinase 3 Ligand (Flt3L) | WB; IHC; ICC; IP. |
| SEA038Mu | ELISA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) | Enzyme-linked immunosorbent assay for Antigen Detection. |
| SCA038Mu | CLIA Kit for FMS Like Tyrosine Kinase 3 Ligand (Flt3L) | Chemiluminescent immunoassay for Antigen Detection. |
ebiomall.com
>
>
>
>
>
>
>
>
>
>
>
>
问题:
1,既然外国公司的原材料这么贵,我就想购买国内厂家的,请各位大侠帮忙提供一下国内哪些厂家的玻璃胚针物廉价美?
2,国内的哪些大学的测试中心,能够提供拉针仪的有偿使用服务的?
脑电波:
脑电波(Electroencephalogram,EEG)是大脑在活动时,大量神经元同步发生的突触后电位经总和后形成的。它记录大脑活动时的电波变化,是脑神经细胞的电生理活动在大脑皮层或头皮表面的总体反映。
脑电波来源于锥体细胞顶端树突的突触后电位。脑电波同步节律的形成还与皮层丘脑非特异性投射系统的活动有关。
脑电波是脑科学的基础理论研究,脑电波监测广泛运用于其临床实践应用中。
电子波
电子波是指电子产品等所发出的电子辐
电子波的害处
电脑及大多数家用电器设备等都是可以产生各种形式不同频率、不同强度的电磁辐射源。
电磁辐射--对人体机理的危害
电场辐射危害人体的机理主要是热效应、非热效应和累积效应等。
热效应:人体70%以上是水,水分子受到电子波辐射后相互摩擦,引起机体升温,从而影响到体内器官的正常工作。
非热效应:人体的器官和组织都存在微弱的电磁场,它们是稳定和有序的,一旦受到外界电场的干扰,处于平衡状态的微弱电场即将遭到破坏,人体也会遭受损伤。
累积效应:热效应和非热效应作用于人体后,对人体的伤害尚未来得及自我修复之前(通常所说的人体承受力---内抗力),再次受到电子波辐射的话,其伤害程度就会发生累积,久之会成为永久性病态,危及生命。对于长期接触电子波辐射的群体,即使功率很小,频率很低,也能诱发体内想不到的病变,应引起警惕。
国家对医疗器械实行分类管理
第一类:按《产品质量法》,通过常规管理,足以保证其安全性,有效性的医疗器械(如血压计、打诊锤、氧气袋、消毒器等)。
第二类:产品机制已取得国际、国内认可,技术成熟,其安全性,有效性必须加以控制的医疗器械(如:电子体温计、脑或心电图机、B超、胃镜、牙科设备等)。
第三类:植入人体、或用于支持生命,或技术结构复杂、对人体可能具有潜在危险、安全性和有效性必须加以痒控制的医疗器械。
编译字数:1452
Neurosurgery:神经外科术中可以同时使用磁共振与神经电生理监测
现代神经外科手术的目的,是实现最大化的肿瘤切除,同时保留神经功能。在过去的十几年间,新的技术工具如神经外科导航系统、低场强和高场强的术中核磁共振成像(iMRI)及先进的神经影像学技术(弥散张量成像技术DTI),以及术中神经电生理监测(IOM)一贯都有助于实现这一目标。但是,这几项技术集成一体化使用往往很难。
对于术中神经元系统和白质束的功能变化,IOM能够提供可靠的评估,而这些变化最终发生在手术中。在肿瘤切除过程中,高场强术中核磁共振成像(iMRI)可以提供残余肿瘤的影像图像,以及显示肿瘤转移和功能途径的形态学改变(通过DTI方式)。大脑雄辩区域的手术要求术中神经电生理监测(IOM),这在提供高场强(1.5T)iMRI的手术室可能会出现一些问题。比如安全性、失真率、IOM与iMRI之间相互干扰导致的可靠性受损。
来自意大利罗马LaSapienza大学医学心理学系神经科学和心理健康感觉器官教研室神经外科的GiancarloD’Andrea博士,为了鉴别在高场强iMRI的手术室里,哪些类型的电极更适合术中神经电生理监测,利用模型进行了一项实验研究。报告了他们在手术期间使用铱铂(Pt/Ir)电极的经验,并且证明IOM与Pt/Ir电极和高场强iMRI之间的集成一体化是安全的、可靠的。文章最近在线发表于Neurosurgery上。
研究人员使用凝胶样模型和苹果,对不同的材料(黄金、Pt/Ir,不锈钢(SS))构成的电极进行测试,以评估他们的安全性和兼容性。随后,在病人使用之前,在5例健康志愿者身上进行了电极测试。研究结果显示,这些不同的电极中,没有任何一个出现热不稳定,并且没有损害志愿者的皮肤的情况发生。
不锈钢电极造成了严重的图像失真。黄金电极没有造成图像失真,但是其高昂的费用使得他们在常规手术中使用负担不起。很明显,铂铱电极比黄金便宜,并且在高场强iMRI的手术室里,其具备完全的安全性、兼容性和适用性,可以提供出色的IOM和温和的干扰,根本不影响术中成像的质量。
因此,高场强的术中核磁共振辅助下的图像引导手术期间,核磁共振兼容的皮下铂铱针电极适用于术中神经电生理监测。在高场强iMRIBrainSuite®中使用IOM是有效的和安全的。
图1本图分为两个部分:在上半部分中,我们展示了我们手术室的照片,包括博医来公司提供的术中核磁共振辅助的脑科手术室(BrainSuite®iMRI)。在下半部分中,原理图描绘了同一手术室的设置证据,关系到逐步地增加与磁场的距离,安全线意味着磁场线使得所在区域的磁场强度逐步减少(10mT、5mT、3mT、1mT,0.5mT)。红线标记的是磁场强度为0.5mT的区域的内边界;因此,在此区域之外进行手术。病人、外科医师、麻醉医师和协助护士的理想位置,以及术中神经电生理监测设备(建议距离病人4-5米)和参与手术的神经生理学家的位置,也都按照上面提到的示意线的建议来事先设计好。附加到磁场的一个回转工作台,允许在手术期间病人的头部置放于5高斯示意线以外。在这条线以外可以使用普通的外科手术器械。术中神经电生理监测设备可以位于更远的地方,幸亏拥有足够7米长的电缆。(IOM=术中神经电生理监测,anesthesiologist=麻醉医师,m=米,mT=毫特斯拉)
图2相比较之下,铂铱电极在凝胶样模型测试期间增加了他们的差别,提供了优良的术中采集的核磁共振信号。(IntraoperativeMRIjellyphantomstudy=凝胶样模型的术中核磁共振成像研究,platinum-iridiumelectrode=铱铂电极,Steelelectrode=钢电极)
图3"苹果测试"更加证实了以前的研究结果,表明铱铂电极具备与术中强磁场最优的兼容性,相比而言,钢电极的人工产品和顺磁性的失真率都很高。(IntraoperativeMRIApplestudy=苹果的术中核磁共振成像研究,platinum-iridiumelectrode=铱铂电极,Steelelectrode=钢电极)
图4术中应用设备在"活体内"的演示图像(IntraoperativeT1VolumetricMRI=术中T1容积核磁共振成像,Intraoperative3Drendering=术中三维渲染图像)
一、脑电图脑电图(EEG)检查:是在头部按一定部位放置8-16个电极,经脑电图机将脑细胞固有的生物电活动放大并连续描记在纸上的图形。正常情况下,脑电图有一定的规律性,当脑部尤其是皮层有病变时,规律性受到破坏,波形即发生变化,对其波形进行分析,可辅助临床对及脑部疾病进行诊断。对脑波的频率、波幅、两侧的对称性以及慢波的数量、部位、出现方式及有无病理波等进行分析。许多脑部病变可引起脑波的异常。如颅内占位性病变(尤其是皮层部位者)可有限局性慢波;散发性脑炎,绝大部分脑电图呈现弥漫性高波幅慢波;此外如脑血管病、炎症、外伤、代谢性脑病等都有各种不同程度的异常,但脑深部和线部位的病变阳性率很低。须加指出的是,脑电图表现没有特异性,必须结合临床进行综合判断,然而对于癫痫则有决定性的诊断价值,在阗痫发作间歇期,脑电图可有阵发性高幅慢波、棘波、尖波、棘一慢波综合等所谓“痛性放电”表现。为了提高脑电图的阳性率,可依据不同的病变部位采用不同的电极放置方法。如鼻咽电极、鼓膜电极和蝶骨电极,在开颅时也可将电极置于皮层(皮层电极)或埋入脑深部结构(深部电极);此外,还可使用各种诱发试验,如睁闭眼、过度换气、闪光刺激、睡眠诱发、剥夺睡眠诱发以及静脉注射美解眠等。但蝶骨电极和美解眠诱发试验等方法,可给病人带来痛苦和损害,须在有经验者指导下进行。随着科技的日益发展,近年来又有了遥控脑电图和24小时监测脑电图。
二、脑电地形图(BEAM)
是在EEG的基础上,将脑电信号输入电脑内进行再处理,通过模数转换和付立叶转换,将脑电信号转换为数字信号,处理成为脑电功率谱,按照不同频带进行分类,依功率的多少分级,最终使脑电信号转换成一种能够定量的二维脑波图像,此种图象能客观地反映各部电位变化的空间分布状态,其定量标志可以用数字或颜色表示,再用打印机打印在颅脑模式图上,或贮存在软盘上。它的优越性在于能发现EEG中较难判别的细微异常,提高了阳性率,且病变部位图象直观醒目,定位比较准确,从而客观对大脑机能进行评价。主要应用于缺血性脑血管病的早期诊断及疗效予后的评价,小儿脑发育与脑波变化的研究,视觉功能的研究,大浮肿瘤的定位以及精神药物的研究等。
三、脑磁图
电流在导体内流动进,导体周围可以产生磁场。同理,脑细胞的电活动也有极微弱的磁场,可用高灵敏度的磁场传感器予以检测,并记录其随时间变化的关系曲线,是即脑磁图,其图形与EEG图形相似。与EEG相比,优点是:可发现有临床意义而又不能被EEG记录到的波形,或检测到皮质局限性的异常电磁活动;此外,磁检器不与头皮接触,也减少了干扰造成的伪差。若与EEG同时描记,还可对不同物理方位的皮质群进行分析。但由于屏蔽、电磁装置以及其他设备复杂、昂贵,目前国内尚无此项设备。
四、诱发电位
给人体感官、感觉神经或运动皮质、运动神经以刺激,兴奋沿相应的神经通路向中枢或外周传导,在传导过程中,产生的不断组合传递的电位变化,即为诱发电位,对其加以分析,即或反映出不同部位的神经功能状态。由于诱发电位非常微小,须借助电脑对重复刺激的信号进行叠加处理,将其放大,并从淹没于肌电、脑电的背景中提取出来,才能加以描记。主要是对波形、主波的潜伏期、波峰间期和波幅等进行分析,为临床诊断提供参考,目前临床常用的有视觉、脑干听觉、体感、运动和事件相关诱发电位,以及视网膜图和耳蜗电图等,可分别反映视网膜、视觉通路、内耳、听神经、脑干、外周神经、脊髓后索、感觉皮质以及上下运动神经元的各种病变,事件相关诱发电位则用以判断患者的注意力和反应能力。诱发电位具有高度敏感性,对感觉障碍可进行客观评诂,对病变能进行定量判断。对心理精神领域可进行一定的检测,故当前广泛应用于对神经系统病变的早期诊断,病情随访,疗效判断,予后估计,神经系统发育情况的评估以及协助判断昏迷性质和脑死亡等。但图形无特异性,必须结合临床资料进行判断;不在有关神经传导径路中的病变,不能发现异常。近年,诱发电位的频谱分析和诱发电位地形图也在临床上逐渐开始应用,进一步提高了其临床应用价值。
五、肌电图(EMG)
是用肌电图仪记录神经和肌肉的生物电活动,对其波形进行测量分析,可以了解神经、肌肉的功能状态,协助对下运动神经元或肌肉疾病的诊断。目前常用的方法有三种:①针极肌电图:亦称普通肌电图,是将特制的针电极刺入肌腹,或用表面电极置于肌肉表面皮肤,在示波器上或记录纸上观察肌肉在静止、轻收缩、重收缩三种状态下的电位变化,以帮助判断疾病究系神经源性或肌源性损害。②神经传导速度测定:也即运动神经传导速度(MCV)和感觉神经传导速度(SCV)测定。系在神经干的近端(MCV)或远端(SCV)给以脉冲刺激,在远端效应肌(MCV)或近端神经走行部位(SCV)接收波形,测理两点之间的潜伏期和距离,即可计算出运动神经或感觉神经传导速度,主要用于了解神经传导功能情况。③其他:如重复频率试验,F波、H反射、牵张反射等检查以及单纤维肌电图检查等,可进一步了解神经、肌肉、神经一肌接头以及脊髓反射弧的功能状态。
六、脑阻抗血流图(REG)
是检查头部血管功能和供血情况的一种方法。其原理是通过放置在头部的电极给以微弱的高频电流,由于血液的电阻率最小,其电阻可随心动周期供血的变化而变化,这种节律性的阻抗变化,经血流图仪放大,可描记出波动性曲线,对其进行测量、计算、分析,可间接了解外周阻力、血管弹性和供血情况。本法简便易行,但因影响因素比较多,如情绪、气温、检查当时的血管功能状态等,故对其判断应加慎重。须结合临床症状,体征等进行判断。常用于脑动脉硬化、闭塞性脑血管病、偏头痛以及药物疗效观察等。