【讨论】关于酮羰基的保护问题 有机 学术科研互动社区
来自 : 蚂蚁淘
Beforehand.
- choose empirically the annealing temperature of primers;
- make sure you have enough PCR-plates, Q-covers and sealing tape;
- prepare the stocks: PCR-buffer, 5M Betaine - with some excess, dNTPs, primers, Taq:Pfu mix (100:1 calculated by activity units) - with small excess;
PCR-reaction.
- thaw the plates with bacterial culture;
- sign the 384-plates;
- prepare PCR-mix;
- dispense PCR mix by multichannel pipet or by "Multidrop 384" machine;
- centrifuge Q-covered (or sealed) plates at ~800 rpm, 3' NT;
- transfer the bacteria twice with the sterile replicators;
- seal the plate and run PCR reaction;
After PCR.
- take the plates out with the help of screwdriver (or forceps);
- move the plates to +4oC and then to -20oC;
- centrifuge at ~800 rpm, 3' NT;
- control PCR by agarose gel electrophoresis: 0.5 - 1µl from 5 - 15 wells;
- seal the plates again;
- move the plates to +4oC and then to -20oC;
- for long term storage - -70oC (keep track in your lab book!).
"Practical Molecular Biology" http://molbiol.ru/eng;e-mail: editor@molbiol.ru
Comments. Detailed instructions, step by step #1. - As a first approximation for the annealing temperature of primers one can use the Tmelting value given by the program "Oligo". Take into account that betaine addition would probably decrease the annealing temperature (sucrose has no effect on it). For example, for the primer pair M-13/23 and M-13/30 maximum annealing temperature decreased from 71oC to 67oC when 1.5M betaine was added.
#3. - It is convenient to have: * all four dNTP's mix (100mM or 25mM stocks);* primers mix.
#4. - Frozen bacteria plates have to be placed on a bench in one layer one by one, separately. This prevents condensation of liquid on the inner side of the cover and transfer of liquid between wells. Condensation occurs when temperature of the cover becomes lower than temperature of the liquid in the plate. It is convenient to use an air fan to accelerate thawing.
#6. - 12.2ml per plate, if PCR volume is 30µl/well (maximum for old ABT-384 plates #TF-0384) or 16.3ml per plate, if PCR volume is 40µl/well (maximum for new ABT-384 plates #AB-0937).
- Add the enzyme last. We were told that Pfu polymerase can destroy primers if PCR mix stored for too long at room temperature. Therefore, just before you add the enzyme, in front of you should be labeled PCR plates, the reservoir for multi-channel pipette, bacterial plates and the replicators. We have tested that it is possible to keep PCR mixture with enzymes at +4oC for about 15h without any decrease of efficiency of PCR reaction.
- After the PCR mix is aliquoted into plates, transfer the remaining volume to 50ml Falcon tube and keep it at -20oC. You can use it for the subsequent experiments (with the same primers), thus minimizing the volume of new PCR master-mix which needs to be prepared.
#8. - Optional — remove air bubbles from bottom of the wells.
#9. - You need twice as much replicators as number of PCR-plates. Insert replicator from the nearest edge, holding it leaned at 5-10o so that the nearest pins are closer to the plate (the row "P" in the PCR plate). The pins should be directed to the center of the wells.
- The purpose of double inoculation is not to increase amount of transferred material but rather to decrease the probability of no transfer at all.
- It is better to mix bacteria in the plate by replicator before transfer. Try to avoid mixing in only one direction, because it can induce sticking of partually lysed bacteria to the needles of replicator.
- The volume of media captured on one needle of the replicator is ca 0.2µl.
- In theory, the plates with inoculated bacteria can be stored at -20oC before PCR up to a few weeks. However, do not freeze them on dry ice. Instead, just put them in the freezer or on the towel soaked with the liquid nitrogen. If freezed on dry ice, evaporating CO2 will shift the pH. If betain- or sucrose-containing PCR mix was used, most likely PCR would succeed anyway, but you don't want be unsure about it, do you?
- The same precautions should be taken for the PCR/NaOH mixtures for spotting. It is possible to freeze them in dry ice (for about 0.5 - 1h) only if they are sealed by "Tesafilm" or "Adhesive Sealing Sheet".
#10. - Sealing films: the best is the office tape from TESA (Tesafilm #2826775): (i) easily taped and removable; (ii) reliable; (iii) cheap - about 10DM per roll. Much worse variants:
- "Adhesive Sealing Sheet" from ABgene: (hardly removable, expensive);
- Microseal "A" film. Fragile: don't press the PCR machine cover very tightly, it can damage Microseal "A", it shrinks after PCR and unsuitable for freezing. For Microseal "A" film:
- when PCR is finished - immediately (plate still in the PCR block) take off the upper film;
- take the plates out of PCR machine;
- remove the isolating film layer;
- get rid of the PCR mix which is in between wells with the yellow tip connected to the vacuum pump;
- use soft blotting paper to remove liquid from the plate surface;
- cover with the "Genetix" covers;
"Bio-stat" film. It has to be sealed tightly, e.g. using the backside of the marker to help. One can put a piece of thin rubber on top, as well. Funny: there were cases when PCR's worked fine with a quite sloppily attached Bio-stat film. In that case considerable volume was evaporated uniformly from each well. Probably there is some sort of equilibrium inside the PCR block so that the content of the well does not dry out completely. For 384-PCR it is better to change the parameter exceed of temperature of the lid "Setup/Lid/Tracking/Lid offset" from the default 15oC to 5oC. PCR-mix: our impression, that in general betaine is slightly worsening PCR reaction. The enzyme speed and activity became lower. But it is impossible to exclude betaine from the buffer for 384 plates. Without it we observed smear, differing from PCR plate to plate (in an 8-strip from the same PCR-mix PCR worked fine). Adding of sucrose has similar effect - the smear partially disappeared, but with betaine - completely. If a sub-cycle PCR is used (see below) the product yield is more stable and a little bit higher (probably it is because of low-melting regions in some sequences). We used the following program: Step: | T (oC): | Time: | 1 | 95 | 1:00 | 2 | 94 | 0:15 | 3 | 59 | 0:15 | 4 | 65 | 0:55 | 5 | go to 3 | 2 add. times | 6 | go to 2 | 29 add. times | 7 | 68 | 10:00 | 8 | 4 | 0 | 9 | END | |
|
#11. Lift each four edges carefully and hold the plate with your hand. Avoid the abrupt moves, if not, your PCR ends up on the cover. The plate holder for 384-plates can be treated with "Teflon spray", then the plate can be removed easier. #14. Concentration should be more then 0.15µg/µl. |
PCR方法相关产品:
- 电泳设备
- 紫外设备
- 普通PCR仪
- 定量PCR仪
PCR/RT-PCR/qPCR试剂
PCR引物
PCR试剂
PCR对照
特异性PCR试剂盒
PCR克隆试剂盒
RNA
RNase检测/去除
RT-PCR试剂
RT-PCR标准品
定量PCR试剂
定量PCR标记
总RNA分离纯化盒
PCR产物纯化
核酸酶
聚合酶
反转录酶
免责声明 本文仅代表作者个人观点,与本网无关。其创作性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不做任何保证或承诺,请读者仅作参考,并请自行核实相关内容。
版权声明 未经蚂蚁淘授权不得转载、摘编或利用其他方式使用上述作品。已经经本网授权使用作品的,应该授权范围内使用,并注明“来源:蚂蚁淘”。违反上述声明者,本网将追究其相关法律责任。