BP-10 spin Column PCR Products Purification Kit
Components | PPP-50 ,50 Preps | PPP-100,100 Preps |
BindingBuffer I Wash Solution (a) Elution Buffer(b) BP-10 Column 2.0 ml Collection Tube | 20ml 12ml 5ml 50 50 | 2x20ml 24ml 10ml 100 100 |
(A)Before use, add 48ml of 96-100% of ethanol to 12ml Wash Solution for PPP-50, or add 96ml of 96-100% ethanol to 24ml Wash Solution for PPP-100. For other volumes of wash solution, simply add enough ethanol to make a 4:1 ratio (volume of added ethanol: volume of Wash Solution = 4:1).
(B)Elution Buffer is 2mM Tris-HCl pH 8.0~8.5. Although TE buffer pH 8.0 or water may be substituted, the resulting yields may be up to 20% lower.
Storage: The kit is stable for 12 months at room temperature.For longer storage, keep all contents cold.
Principle:
BP-10 spin column purification kits utilize a silica-gel membrane which selectively absorbs up to 50ug of DNA fragments in the presence of specialized binding buffers. Nucleotides, oligos (<40-mer), enzymes, mineral oil and other impurities do not bind to the membrane and are washed away. The DNA fragments can then be eluted off the column in small volume and used in downstream applications without further processing.
Application:
- Recovery of PCR products from PCR reaction mixture.
- Recovery of DNA fragments from reaction solutions.
Features:
- Quick and economical.The entire procedure takes 15-20 minutes.
- High yields (60-90%) of 60bp-40kb DNA fragments.
- Efficient removal of contaminants. Purified DNA can be used in any downstream application such as sequencing, labeling, restriction enzymatic digestion, ligation or transformation.
- No phenol / chloroform extraction or ethanol precipitation is required.
Protocol for Purification of PCR Products:
1.Transfer PCR reaction mixture to a 1.5ml microfuge tube and add 3 volumes of Binding Buffer I.
2.Transfer the above mixture solution to the BP-10 column and let stand at room temperature for 2 minutes. Centrifuge at 5000 rpm for 1 minute.
3.Remove the flow-through in the tube. Add 500ul of Wash Solution to the column and centrifuge at 8,000 rpm for 1minute.
4.Repeat washing procedure in step 3. Spin at 8,000 rpm for an additional minute to remove any residual Wash Solution.
5.Transfer the column into a clean 1.5ml microfuge tube and add 30-50ul of Elution Buffer. Incubate at room temperature for 2 minutes. Centrifuge at 10,000 rpm for an additional 2 minutes to elute the DNA.
Note: It is extremely important to add the Elution Buffer to the center of the column. Incubating the column at higher temperatures (37º to 50ºC) may slightly increase the yield. Or prewarming the Elution Buffer at 55º to 80ºC may also slightly increase elution efficiency.
If a higher DNA concentration is desirable, 20ul (or less) of elution buffer can be used to elute the DNA. It is critical that the elution buffer be applied directly in the center of the column. (To recover maximum amount of DNA it is recommended to repeat the elution step.).
6.Store the purified DNA at -20ºC.
Note:
1.If PCR reaction mixture contains seriously non-specific amplified DNA fragments, use of the DNA Gel Extraction Kit is recommended.
2.This kit can not remove the template and primers with chain length longer than 50-mer.
ebiomall.com
>
>
>
>
>
>
>
>
>
>
>
>
我们维克奇专门做标准品/对照品的,产品纯度要大于等于百分之九十八,可以看看我们的网站信息
药品标准物质由中国药品生物制品检定所负责标定。中国药品生物制品检定所可以组织有关的省、自治区、直辖市药品检验所、药品研究机构或者药品生产企业协作标定国家药品标准物质。
药品标准物质分类包括:标准品、对照品、对照试剂、对照制剂、对照药材、标准量具或耗材、工作标准品、精品。
如果你需要购买 药品对照品、标准品,可以到中国药品生物制品检定所订购,也可以查询中国标准物质网订购。
各们前辈,初涉诊断行业,开发PCR诊断试剂,求问微生物标准品或者质控血清(比如支原体、衣原体、金葡菌等)应该到哪里购买啊?中检所和卫生部临检中心好像都没有。谢谢!