请使用支持JavaScript的浏览器! +,Immunosome®-PDP (Non-PEGylated) - Encapsula NanoSciences- Manufacturer of liposome based kits and formulations for research laboratories蚂蚁淘商城
商品信息
联系客服
Encapsula/Immunosome®-PDP (Non-PEGylated)/2-ml/IMS-2059-2-ml
郑重提醒:
无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
Encapsula/Immunosome®-PDP (Non-PEGylated)/2-ml/IMS-2059-2-ml
品牌 / 
Encapsula
货号 / 
IMS-2059-2-ml
美元价:
(友情提示:该价格仅为参考,欢迎联系客服询价!)
数    量:
免费咨询热线
4000-520-616

Description

During the past five decades, various types of chemistries have been used for conjugation of molecules such as antibodies, peptides, proteins or other reactive ligands to the surface of liposomes. In general, the conjugation can be achieved through the N-terminus, the C-terminus or the available sulfur (e.g. Fab’ fraction or thiolated antibodies). Not all chemistries have the same yield and efficiency of conjugation and often reproducing biocompatible batches can be a challenge. The liposomes containing pyridyldithiopropionate (PDP) lipids are used to conjugate proteins, antibodies and other molecules containing the reactive moiety. PDP lipids are not as widely used as maleimide lipids, but they do have their own niche application. The PDP group contains disulfide, which can react with sulfhydryl or thiolated proteins/antibodies. Therefore, PDP-functionalized liposomes can be used in two ways:

Method A. In this approach, the pyridyldithio group of the PDP is first reduced by a reducing agent (dithiothreitol, DTT). Maleimide-containing antibodies are then efficiently coupled to the surface of liposomes. The thiol-maleimide procedure is one of the most desirable reactions in bioconjugate chemistry due to its simplicity and high coupling efficiency in aqueous solution. The reaction, which is based on the stable thioether linkage between a thiol group (reduced form of PDP-liposome) and the corresponding maleimide group, occurs selectively and irreversibly at neutral pH (6.5-7.5), and the formed bonds are not cleaved by reducing agents. In addition, due to the presence of two different oxidation states of sulfur residues (oxidized and reduced states as a disulfide bond and sulfhydryl group, respectively) on the two conjugating components (i.e., the liposome and protein/antibody), the probability of the crosslinking of the homologous agents is low. Therefore, protein-protein and liposome-liposome crosslinking does not usually happen.

Method B. Alternatively, the PDP group can participate in disulfide exchange reactions with thiols present on targeting proteins/antibodies. The coupling reaction is fast and conducted under mild conditions. However, the formed disulfide bonds have been reported to be less stable than thioether bonds. Moreover, even in an alkaline medium (pH 8.0), thiol groups are oxidized. The disulfide bond formed between the protein/antibody and liposomes can also be broken in the presence of a reducing agent and therefore, the conjugation reaction is reversible.

Method A. Conjugation of maleimide-modified antibody to a PDP-modified liposome.

Method B. Conjugation of a thiol-modified antibody to a PDP-modified liposome.

Immunosome®-PDP is a non-PEGylated product. For the other reactive (PEGylated and non-PEGyalated products) Immunosome® products suitable for other types of conjugation method see here.

Download Product InsertDownload Safety Datasheet (SDS)

Formulation Information

Immunosome®-PDP (Non-PEGylated)

Lipid CompositionConcentration (mg/ml)Concentration (mM)Molar Ratio Percentage
Total14.82 mg/ml22.45 mM100
L-alpha-Phosphatidylcholine1215.569
Cholesterol2.66.7330
1,2-Dioleoyl-sn-glycero-3-phosphoethanolamine-N-[3-(2-pyridyldithio)propionate]0.220.221
Buffer and Liposome Size Specification
BufferPhosphate Buffered Saline
pH7.4
Liposome Size100 nm

Conjugation Protocol

Materials and Equipment

  1. Laboratory vortex mixer is recommended to have.
  2. Laboratory magnetic stirrer is needed for dialysis.
  3. Float-A-Lyzer® with a proper MWCO that easily allows the cleanup of your liposome conjugated ligand from free and non-conjugated protein/peptide/ligand. You need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore your liposomes can be dialyzed out. You cannot use dialysis cassettes blindly. Please understand the technique before using either spin columns or dialysis cassettes. If you do not use the correct MWCO, you can lose your entire prep. For this protocol we recommend MWCO of 300,000 dalton.
  4. Sephadex® G-15 column.
  5. DL-dithiothreitol (DTT) (for method A).
  6. Ethylenediaminetetraacetic acid (EDTA) (for method B).

Preparation Method

Method A

  1. The total lipid concentration in Immunosome®-PDP is 22.45 mM. 1% mol of the lipid in liposomes contains PDP group and only half of them are exposed to the outside of the liposomes, which is equal to 0.11 mM of reactive conjugable lipid. For 2 ml volume liposomes, this is equal to 2.20×10-7 mol, and for 5 ml volume liposomes, this is equal to 5.50×10-7 mol of PDP. To reduce the disulfide linkage, incubate the liposome containing PDP with DTT solution (liposome-PDP:DTT molar ratio of 1:250) to a final concentration of 20 mM for 30 min at room temperature.
  2. Separate DTT by passing the liposomes over a Sephadex® G-15 column eluted with 25 mM HEPES, 25 mM MES, 140 mM NaCl, pH 6.7 buffer.
  3. Immediately after removing DTT, incubate the thiolated liposomes with the maleimide-modified protein/antibody at a ligand:liposome molar ratio of 1:1000 (ligand:active lipid, 1:10 molar ratio) for overnight at room temperature. 
  4. The free thiols on the liposome surface are blocked by incubation the suspension with iodoacetamide (0.2 mM) for 2 h at room temperature.
  5. Remove the non-conjugated protein, peptide or antibody from the immunoliposomes by dialysis. We prefer dialysis to size exclusion columns. Dialysis is a much slower process but there will be minimum loss of immunoliposomes after the prep is cleaned from non-conjugated protein/peptide/ligand. Spin columns are much faster; however, you can easily lose over 50% of the liposomes on the spin column. We recommend using Float-A-Lyzer® dialysis cassette from Spectrum Labs. You will need to choose a cassette with proper MWCO depending on the MW of your protein, peptide, antibody or antibody fragment. NOTE: If you decide to use a dialysis cassette, you will need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore, your liposomes can be dialyzed out. You cannot use dialysis cassettes and spin columns blindly. They come in various sizes and you need to choose the correct size wisely. Dialyze the immunoliposome solution in 1 liter of PBS at pH 7.4 for 8 hours. Change the dialysis buffer with a fresh 1 liter of PBS and let is dialyze for another 8 hours. After this step, your cleaned up immunoliposome is ready to be used.

Method B

  1. The total lipid concentration in Immunosome®-PDP is 22.45 mM. 1% mol of the lipid in liposomes contains PDP group and only half of them are exposed to the outside of the liposomes, which is equal to 0.11 mM of reactive conjugable lipid. For 2 ml volume liposomes, this is equal to 2.20×10-7 mol, and for 5 ml volume liposomes, this is equal to 5.50×10-7 mol of PDP. Add the sulfhydryl-containing protein/antibody to PDP-liposome at 1:1000 molar ratio (ligand:active lipid, 1:10 molar ratio). In order to prevent metal-catalyzed oxidation of sulfhydryl, the reaction should be done in the presence of 10 mM EDTA. The pH is adjusted to 8.0 and the coupling reaction allowed to proceed overnight at room temperature with stirring under nitrogen or argon atmosphere to prevent lipid oxidation.
  2. Remove the non-conjugated protein, peptide or antibody from the immunoliposomes by dialysis. We prefer dialysis to size exclusion columns. Dialysis is a much slower process but there will be minimum loss of immunoliposomes after the prep is cleaned from non-conjugated protein/peptide/ligand. Spin columns are much faster; however, you can easily lose over 50% of the liposomes on the spin column. We recommend using Float-A-Lyzer® dialysis cassette from Spectrum Labs. You will need to choose a cassette with proper MWCO depending on the MW of your protein, peptide, antibody or antibody fragment. NOTE: If you decide to use a dialysis cassette, you will need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore, your liposomes can be dialyzed out. You cannot use dialysis cassettes and spin columns blindly. They come in various sizes and you need to choose the correct size wisely. Dialyze the immunoliposome solution in 1 liter of PBS at pH 7.4 for 8 hours. Change the dialysis buffer with a fresh 1 liter of PBS and let is dialyze for another 8 hours. After this step, your cleaned up immunoliposome is ready to be used.

Quantification of reactive sulfhydryl in antibodies or ligands (Ellman’s Assay)

The yield of conjugation is the most important factor in formulating immunoliposomes. Many scientists simply assume that their thiolated antibody or the Fab’ fraction contains reactive sulfhydryl for conjugation to maleimide lipid without further assay. Disulfide bridge can form very easily so it is very important to quantify the available reactive sulfhydryl in your antibody or ligand solution before performing the conjugation reaction with maleimide liposomes.

Ellman’s assay is a widely used assay for determining the amount of free sulfhydryl. You can follow the step by step protocol here.

Liposome Particle Calculator

Immunosomes are unilamellar liposomes and sized to 100 nm. The molar concentration of liposome is 22.45 mM. By having liposome diameter (nm) and lipid concentration (µM), you can calculate the total number of the lipids in one liposome and the number of the liposomes in one milliliter of the liposome solution. To use the calculator click here.

Technical Notes

  • After conjugation reactions, liposomes containing excess maleimide or thiol groups may exhibit undesirable qualities, such as aggregation, reactions in vitro and in vivo, and immunogenicity. These reactive moieties can be quenched with reagents containing iodo-, maleimide, or sulfhydryl groups, where appropriate. This is likely to be a particularly serious problem for thiolated liposomes. Therefore, it is recommended that the antibody to be thiolated in order to generate the appropriate reactive entities for the final conjugation reaction.
  • In order to prevent oxidation of sulfhydryl on antibody and formation of disulfide bridge, the coupling reaction must be performed under an inert atmosphere such as argon or nitrogen. To set up a inert gas chamber we recommend using Aldrich®-Atmosbag with is a flexible, inflatable polyethylene chamber with built-in gloves which is a portable and inexpensive alternative to laboratory glove box.
  • Maleimide group on lipid is highly sensitive of alkaline pH and it will hydrolyze rapidly at higher pH. Experimental investigations have been shown that in alkaline condition (pH > 7.5), maleimide and its derivatives are hydrolyzed to a non-reactive maleamic acid (see the figure below). This instability should be considered in any quantitative procedures, such as coupling with sulfhydryl groups. Therefore, it is very important to make sure that the pH of the reaction with stay between 6.5 and 7 during the entire process.
  • If your goal is to conjugate a thiolated protein/antibody containing reactive sulfhydryl to liposomes to form an immunoliposome, it is recommended to use liposomes containing maleimide reactive lipids.
  • The amount of the maleimide-activated protein/antibody bound per liposome in Method A depends on the number of free thiols on the liposome surface (formed in step 1) and the reaction efficiency increases with increasing PDP/mAb molar ratio in the incubation mixture.
  • If you are using a ligand or peptide that is hydrophobic then it is recommended to solubilize it in DMSO or DMF and then add the buffer to it. It is recommended not to use more than 5% volume of DMSO or DMF in the solution. DMF and DMSO are both compatible with liposomes and they are also miscible in water. Other organic solvent such as ethanol and chloroform are not compatible with liposomes and will cause the liposomes to lyse. If you end up using DMSO or DMF then after the conjugation reaction is done, you need to remove DMSO and DMF from the liposomes. In order to do that, you need to use a dialysis cassette that is made from REGENERATED CELLULOSE MEMBRANE. NOTE: Not all membranes are compatible with DMF and DMSO. We recommend using a Slide-A-Lyzer™ MINI Dialysis Device with MWCO of 2K made from regenerated cellulose membrane manufactured by ThermoFisher. After DMSO or DMF is removed you can use Float-A-Lyzer® dialysis device for the final step of cleaning up the prep.
  • Liposomes should be kept at 4°C and NEVER be frozen.

Database

Direct link to the database page for easy navigation: Immunoliposomes Conjugation Database

Appearance

Immunosome®-PDP is a white translucent liquid made of nano size unilamellar liposomes. Usually due to the small size of liposomes no settling will occur in the bottom of the vial. The liposomes are packaged in an amber vial. 

Ordering/Shipping Information

  • All liposome based formulations are shipped on blue ice at 4°C in insulated packages using overnight shipping or international express shipping.
  • Liposomes should NEVER be frozen. Ice crystal that form in the lipid membrane can rupture the membrane, change the size of the liposomes and cause the encapsulated drug to leak out. Liposomes in liquid form should always be kept in the refrigerator.
  • Clients who order from outside of the United States of America are responsible for their government import taxes and customs paperwork. Encapsula NanoSciences is NOT responsible for importation fees to countries outside of the United States of America.
  • We strongly encourage the clients in Japan, Korea, Taiwan and China to order via a distributor. Tough customs clearance regulations in these countries will cause delay in custom clearance of these perishable formulations if ordered directly through us. Distributors can easily clear the packages from customs. To see the list of the distributors click here.
  • Clients ordering from universities and research institutes in Australia should keep in mind that the liposome formulations are made from synthetic material and the formulations do not require a “permit to import quarantine material”. Liposomes are NOT biological products.
  • If you would like your institute’s FedEx or DHL account to be charged for shipping then please provide the account number at the time of ordering.
  • Encapsula NanoSciences has no control over delays due to inclement weather or customs clearance delays. You will receive a FedEx or DHL tracking number once your order is confirmed. Contact FedEx or DHL in advance and make sure that the paperwork for customs is done on time. All subsequent shipping inquiries should be directed to Federal Express or DHL.

Storage and Shelf Life

Storage

Immunosome® products should always be stored at in the dark at 4°C, except when brought to room temperature for brief periods prior to animal dosing. DO NOT FREEZE. If the suspension is frozen, the encapsulated drug can be released from the liposomes thus limiting its effectiveness. In addition, the size of the liposomes will also change upon freezing and thawing.

Shelf Life

Immunosome®-PDP (Non-PEGylated) is made on daily basis. The batch that is shipped is manufactured on the same day. It is advised to use the products within 4 months of the manufacturing date.

References and background reading

1. Shi M, Lu J, Shoichet MS. Organic nanoscale drug carriers coupled with ligands for targeted drug delivery in cancer. Journal of Materials Chemistry. 2009;19(31):5485-98.

2. Mercadal M, Domingo JC, Petriz J, Garcia J, De Madariaga MA. A novel strategy affords high-yield coupling of antibody to extremities of liposomal surface-grafted PEG chains. Biochimica et Biophysica Acta (BBA)-Biomembranes. 1999 Apr 14;1418(1):232-8.

3. Bendas G, Krause A, Bakowsky U, Vogel J, Rothe U. Targetability of novel immunoliposomes prepared by a new antibody conjugation technique. International journal of pharmaceutics. 1999 Apr 20;181(1):79-93.

4. Allen TM, Brandeis E, Hansen CB, Kao GY, Zalipsky S. A new strategy for attachment of antibodies to sterically stabilized liposomes resulting in efficient targeting to cancer cells. Biochimica et Biophysica Acta (BBA)-Biomembranes. 1995 Jul 26;1237(2):99-108.

5. Martin FJ, Hubbell WL, Papahadjopoulos D. Immunospecific targeting of liposomes to cells: a novel and efficient method for covalent attachment of Fab’fragments via disulfide bonds. Biochemistry. 1981 Jul;20(14):4229-38.

6. Torchilin V, Weissig V. Liposomes: a practical approach. Oxford University Press; 2003 Jun 5.

7. Kim MJ, Lee HJ, Lee IA, Kim IY, Lim SK, Cho HA, Kim JS. Preparation of pH-sensitive, long-circulating and EGFR-targeted immunoliposomes. Archives of pharmacal research. 2008 Apr 1;31(4):539-46.

蚂蚁淘电商平台
ebiomall.com
公司介绍
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
Goryo Chemical公司产品介绍【代理商代购现货】 查看更多>
2021-08-08
上海研生实业有限公司所提供的周期素D1免疫组化试剂盒质量可靠、规格齐全,上海研生实业有限公司不仅具有精湛的技术水平,更有良好的售后服务和优质的解决方案,欢迎您来电咨询此产品具体参数及价格等详细信息! 查看更多>
上海研生实业有限公司所提供的胶质纤维酸性蛋白免疫组化试剂盒质量可靠、规格齐全,上海研生实业有限公司不仅具有精湛的技术水平,更有良好的售后服务和优质的解决方案,欢迎您来电咨询此产品具体参数及价格等详细信息! 查看更多>
Helper T cells are found in two distinct cell types, Th1 and Th2, distinguished by the cytokines they produce and respond to and the immune responses they are 查看更多>
免疫组化实验中常见的几种溶液配制方法 查看更多>
上海研生实业有限公司所提供的细胞角蛋白 7免疫组化试剂盒质量可靠、规格齐全,上海研生实业有限公司不仅具有精湛的技术水平,更有良好的售后服务和优质的解决方案,欢迎您来电咨询此产品具体参数及价格等详细信息! 查看更多>
人GFAP 免疫组化试剂盒 该试剂盒以HRP 标记的链霉亲和素复合物(HRP Streptavidin Conjugate,HRP-SA)为基础,可用于检测细胞、组织内的特异性GFAP 抗原。该试剂盒具有灵敏度高、特异性强、定性定位准 查看更多>
上海研生实业有限公司所提供的PARP-1(cleaved p25)免疫组化试剂盒质量可靠、规格齐全,上海研生实业有限公司不仅具有精湛的技术水平,更有良好的售后服务和优质的解决方案,欢迎您来电咨询此产品具体参数及价格等详细信息! 查看更多>
上海研生实业有限公司所提供的β-连环蛋白免疫组化试剂盒质量可靠、规格齐全,上海研生实业有限公司不仅具有精湛的技术水平,更有良好的售后服务和优质的解决方案,欢迎您来电咨询此产品具体参数及价格等详细信息! 查看更多>
上海研生实业有限公司所提供的间变型淋巴瘤激酶磷酸化抗体免疫组化试剂盒质量可靠、规格齐全,上海研生实业有限公司不仅具有精湛的技术水平,更有良好的售后服务和优质的解决方案,欢迎您来电咨询此产品具体参数及价格等详细信息! 查看更多>
上海研生实业有限公司所提供的人谷胱甘肽-S-转移酶-π(GST-π)免疫组化试剂盒质量可靠、规格齐全,上海研生实业有限公司不仅具有精湛的技术水平,更有良好的售后服务和优质的解决方案,欢迎您来电咨询此产品具体参数及价格等详细信息! 查看更多>
上海沪震实业有限公司在发布的即用型SABC-POD免疫组化试剂盒 (适用人/大鼠/小鼠/山羊/兔中一种)供应信息,浏览与即用型SABC-POD免疫组化试剂盒 (适用人/大鼠/小鼠/山羊/兔中一种)相关的产品或在搜索更多与即用型SABC-POD免疫组化试剂盒 (适用人/大鼠/小鼠/山羊/兔中一种)相关的内容。 查看更多>
常见问题
蚂蚁淘所售产品均为正品吗?
蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
下单后可以修改订单吗?
未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
商品几天可以发货?
现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
订单如何取消?
如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
可以开发票吗?
本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
如何联系商家?
蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
收到的商品少了/发错了怎么办?
同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
退换货/维修需要多长时间?
一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
商品咨询
如果温度超过了保存温度,那么就不能使用了 一般按照试剂盒上的保存要求进行储存本数据来源于百度地图,最终结果以百度地图最新数据为准。
请教做多药耐药的免疫组化试剂盒都有哪些厂家生产呀??谢谢
各位战友大家好!我目前在做SD大鼠腹主动脉球囊损伤模型,模型刚刚建成,需要检验模型是否建成功。需要做一个免疫组化。可是咨询了几家试剂公司,都没有PCNA免疫组化的试剂盒。想咨询各位战友们,有谁知道哪家有卖SD大鼠血管PCNA免疫组化试剂盒的,请指点一二,哪家的试剂盒比较好。我的联系方式是463843267@qq.com。谢谢!
免疫组化试剂盒检测标本的数量和你盒子大小有直接关系,盒子大的检测的就多!
免疫组化试剂盒,有国产的和进口的
上海好多的供应商的,具体还是看你选择了,其实试剂盒产品都差不多,什么远慕生物,古朵生物...好多的额
即用型快捷免疫组化 MaxVision TM 试剂盒是根据聚合物技术把过氧化物酶与抗鼠或/和抗兔IgG分子结合在多聚物上形成多聚物分子。
小鼠IFN-γR免疫组化试剂盒哪个公司的好?请各位前辈指点,谢谢!:)
用哪家公司的免疫组化试剂盒好一些?打算用SABC染色的,其他方法也行。
我做肉瘤的免疫组化一抗用的ABCom,二抗和DAB用的博士德,但是做了几次都没有任何染色。由于烘箱60度烤片我只烤了20分钟,可能时间短了,但苏木素可以染上,是否说明烤片、脱蜡已足够。
用双氧水去除过氧化物酶时,我是自己配的3%双氧水滴到片上而非将片浸入双氧水,这样可否?
用博士德的DAB染色,配制方法为:1mlH20中加入DAB、H2O2、TBS各一滴,我配制的时候发现将DAB加入H20时很容易沉淀,要震荡才能混匀,且将配好的DAB滴到玻片上时,DAB会结为很小块的微颗粒悬浮在液体中但并不染色,是否DAB有问题?
现在打算换中衫的试剂盒,代理商说中衫的试剂盒包括了二抗和DAB,想请教一下该试剂盒的具体内容有些什么?
万分感谢!
本数据来源于百度地图,最终结果以百度地图最新数据为准。做TUNEL和MMP-2、MMP-9的免疫组化
实验进度比较紧,近期急求dako公司的envision试剂盒免疫组化非生物素二抗系统,需要做50张片子,但官方最小的版本是做500张片子,供应商要价13000,所以求助大家,是否曾经购置此试剂,愿购买或交换相关资源,谢谢!谢谢!
如能成功,愿追加50个或更多蚁豆,麻烦大家帮忙~~