CLIA Kit for Erythropoietin (EPO)
EP; Epoetin; Erythropoetin; Hematopoietin; Hemopoietin
- Product No.SCA028Mu
- Organism SpeciesMus musculus (Mouse) Same name, Different species.
- All
- Human
- Mouse
- Rat
- Cavia
- Rabbit
- Simian
- Caprine
- Ovine
- Equine
- Bovine
- Porcine
- Gallus
- Canine
- Others
- Multi-species
- Pan-species
- Test MethodDouble-antibody Sandwich
- Assay Length2h, 40min
- Detection Range1.37-1,000pg/mL
- SensitivityThe minimum detectable dose of this kit is typically less than 0.59pg/mL.
- Sample Typeserum, plasma, tissue homogenates, cell lysates and other biological fluids
- DownloadInstruction Manual
- UOM48T96T96T*596T*1096T*100
- FOBUS$ 605 For more details, please contact local distributors!US$ 864 For more details, please contact local distributors!US$ 3888 For more details, please contact local distributors!US$ 7344 For more details, please contact local distributors!US$ 60480 For more details, please contact local distributors!
Specificity of the CLIA Kit for Erythropoietin (EPO)
This assay has high sensitivity and excellent specificity for detection of Erythropoietin (EPO).No significant cross-reactivity or interference between Erythropoietin (EPO) and analogues was observed.
Recovery of the CLIA Kit for Erythropoietin (EPO)
Matrices listed below were spiked with certain level of recombinant Erythropoietin (EPO) and the recovery rates were calculated by comparing the measured value to the expected amount of Erythropoietin (EPO) in samples.
Matrix | Recovery range (%) | Average(%) |
serum(n=5) | 90-103 | 98 |
EDTA plasma(n=5) | 85-102 | 93 |
heparin plasma(n=5) | 93-101 | 97 |
Precision of the CLIA Kit for Erythropoietin (EPO)
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Erythropoietin (EPO) were tested 20 times on one plate, respectively. Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Erythropoietin (EPO) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100 Intra-Assay: CV<10%>10%>Inter-Assay: CV<12%>12%>
Linearity of the CLIA Kit for Erythropoietin (EPO)
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Erythropoietin (EPO) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample | 1:2 | 1:4 | 1:8 | 1:16 |
serum(n=5) | 80-102% | 79-105% | 96-105% | 83-101% |
EDTA plasma(n=5) | 90-97% | 86-101% | 96-105% | 95-104% |
heparin plasma(n=5) | 83-101% | 95-102% | 93-101% | 96-104% |
Stability of the CLIA Kit for Erythropoietin (EPO)
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Assay procedure summary of the CLIA Kit for Erythropoietin (EPO)
1. Prepare all reagents, samples and standards;2. Add 100µL standard or sample to each well. Incubate 1 hours at 37°C;3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C;4. Aspirate and wash 3 times;5. Add 100µL prepared Detection Reagent B. Incubate 30 minutes at 37°C;6. Aspirate and wash 5 times;7. Add 100µL Substrate Solution. Incubate 10 minutes at 37°C;8. Read RLU value immediately.
Test principle of the CLIA Kit for Erythropoietin (EPO)
The microplate provided in this kit has been pre-coated with an antibody specific to Erythropoietin (EPO). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Erythropoietin (EPO). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Erythropoietin (EPO) level in the sample or standard.;
GIVEAWAYS
ELISA / CLIA Experiment Service
INCREMENT SERVICES
Single-component Reagents of Assay KitLysis Buffer Specific for ELISA / CLIAQuality Control of ELISA / CLIACLIA Kit Customized ServiceDisease Model Customized ServiceSerums Customized ServiceTGFB1 Activation ReagentReal Time PCR Experimental ServiceStreptavidin
Related products
Catalog No. | Organism species: Mus musculus (Mouse) | Applications (RESEARCH USE ONLY!) |
RPA028Mu03 | Recombinant Erythropoietin (EPO) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA028Mu01 | Recombinant Erythropoietin (EPO) | Positive Control; Immunogen; SDS-PAGE; WB. |
RPA028Mu02 | Recombinant Erythropoietin (EPO) | Positive Control; Immunogen; SDS-PAGE; WB. |
PAA028Mu02 | Polyclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
PAA028Mu01 | Polyclonal Antibody to Erythropoietin (EPO) | WB; IHC; ICC; IP. |
SEA028Mu | ELISA Kit for Erythropoietin (EPO) | Enzyme-linked immunosorbent assay for Antigen Detection. |
MEA028Mu | Mini Samples ELISA Kit for Erythropoietin (EPO) | Enzyme-linked immunosorbent assay for Antigen Detection. |
SCA028Mu | CLIA Kit for Erythropoietin (EPO) | Chemiluminescent immunoassay for Antigen Detection. |
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
求Hema9600基因扩增仪用户手册,实验室有这个仪器,官网(http://www.zhhema.com/zh-CN/displayproduct.html?proID=100438154)找不到说明书。
308C是16孔道的,单次反应可检测1-14项不同指标。
要做滚环扩增,实验室没有荧光光谱仪,可以用荧光定量PCR仪代替吗?
(1)水浴式PCR仪:变温快、时间准、温度均一,但体积大,自动化程度不高。
(2)变温金属块式PCR仪:通过半导体加热和冷却,并由微机控制恒温和冷热处理过程。装置比较牢固耐用,温度变换平稳,有利于保持Taq DNA聚合酶的活性。
(3)变温气流式PCR仪:以空气作为热传播媒介,由大功率风扇及制冷设备提供外部冷空气而制冷。成本较低;安全程度高。微机配上软件,可灵活编程。