
Description
During the past five decades, various types of chemistries have been used for conjugation of molecules such as antibodies, peptides, proteins or other reactive ligands to the surface of liposomes. In general, the conjugation can be achieved through the N-terminus, the C-terminus or the available sulfur (e.g. Fab’ fraction or thiolated antibodies). Not all chemistries have the same yield and efficiency of conjugation and often reproducing biocompatible batches can be a challenge.
Copper-free click chemistry is a fairly new chemistry that has been commercialized during the past few years. More and more click chemistry-based reagents are becoming available commercially which makes the formulation development much easier for scientists. The great advantage of this chemistry is biocompatibility since no cytotoxic copper catalyst is required. By far, click chemistry is the most efficient and easiest conjugation chemistry available for coupling of antibodies and other reactive ligands to the surface of the liposomes. The conjugation chemistry is based on the reaction of the dibenzocyclooctyne (DBCO) reagent with an azide linker to form a stable triazole. DBCO moiety can be on the antibody and azide moiety can be on liposomes and vice versa. This conjugation protocol is based on the reaction of the dibenzocyclooctyne (DBCO) group of the liposomes with an azide linker on the antibody, peptide or proteins.
There are many commercialized reagents that can be used for azide modification of proteins, peptides and antibodies. To see the list of commercialized reagents for azide modification see here.

For other reactive (PEGylated and non-PEGyalated products) Immunosome® products suitable for other types of conjugation method see here.
Formulation Information
Immunosome®-DBCO (Non-PEGylated)
Lipid Composition | Concentration (mg/ml) | Concentration (mM) | Molar Ratio Percentage |
---|---|---|---|
Total | 14.84 mg/ml | 22.45 mM | 100 |
L-alpha-Phosphatidylcholine | 12 | 15.5 | 69 |
Cholesterol | 2.6 | 6.73 | 30 |
1,2-Dioleoyl-sn-glycero-3-phosphoethanolamine-N-dibenzocyclooctyl![]() | 0.24 | 0.22 | 1 |
Buffer and Liposome Size | Specification |
---|---|
Buffer | Phosphate Buffered Saline |
pH | 7.4 |
Liposome Size | 100 nm |
Conjugation Protocol
Materials and Equipment
You need the following materials and equipment in order to use the kit.
- Laboratory vortex mixer is recommended to have.
- Laboratory magnetic stirrer is needed for dialysis.
- Float-A-Lyzer® with a proper MWCO that easily allows the cleanup of your liposome conjugated ligand from free and non-conjugated protein/peptide/ligand. You need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore your liposomes can be dialyzed out. You cannot use dialysis cassettes blindly. Please understand the technique before using either spin column or dialysis cassette. If you do not use the correct MWCO, you can lose your entire prep. For this protocol, we recommend MWCO of 300,000 dalton.
Preparation Method
- The total lipid concentration in Immunosome®-DBCO is 22.45 mM. 1% mol of the lipid in liposomes contains DBCO group and only half of them are exposed to the outside of the liposomes, which is equal to 0.11 mM of reactive conjugable lipid. For 2 ml volume liposomes, this is equal to 2.20×10-7 mol, and for 5 ml volume liposomes, this is equal to 5.50×10-7 mol of DBCO. Add 2.5 mol equivalent of DBCO-lipids in liposomes to 1 mol equivalent of azide containing protein. Incubate the mixture of liposome and antibody at room temperature for 4 h followed by overnight incubation at 4°C in a refrigerator.
- Remove the non-conjugated protein, peptide or antibody from the immunoliposomes by dialysis. We prefer dialysis to size exclusion columns. Dialysis is a much slower process but there will be minimum loss of immunoliposomes after the prep is cleaned from non-conjugated protein/peptide/ligand. Spin columns are much faster; however, you can easily lose over 50% of the liposomes on the spin column. We recommend using Float-A-Lyzer® dialysis cassette from Spectrum Labs. You will need to choose a cassette with proper MWCO depending on the MW of your protein, peptide, antibody or antibody fragment. NOTE: If you decide to use a dialysis cassette, you will need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore, your liposomes can be dialyzed out. You cannot use dialysis cassettes and spin columns blindly. They come in various sizes and you need to choose the correct size wisely. Dialyze the immunoliposome solution in 1 liter of PBS at pH 7.4 for 8 hours. Change the dialysis buffer with a fresh 1 liter of PBS and let is dialyze for another 8 hours. After this step, your cleaned up immunoliposome is ready to be used.
Liposome Particle Calculator
Immunosomes are unilamellar liposomes and sized to 100 nm. The molar concentration of liposome is 22.45 mM. By having liposome diameter (nm) and lipid concentration (µM), you can calculate the total number of the lipids in one liposome and the number of the liposomes in one milliliter of the liposome solution. To use the calculator click here.
Technical Notes
- Before starting the conjugation process please make sure to avoid buffers that contain azides, which can react with DBCO.
- DBCO group is known to be hydrophobic and it buries itself in the lipid bilayer of the liposomes. Direct conjugation of a ligand to the liposomes containing DBCO has produced immunoliposomes with yield of above 60% which is quite acceptable and much higher than many other conjugation chemistries. Post-insertion of DBCO lipid conjugated ligands into the liposomes increases the yield to above 80%. For more information see reference 11.
- Reactions of DBCO and azides are more efficient at high concentrations and temperatures (i.e., up to 37°C). In order to avoid denaturation of proteins, peptides and antibodies, it is recommended to incubate molecules with liposomes at room temperature followed by refrigeration (see step 1).
- Typical reaction times are less than 12 h, however, incubating for longer can improve efficiency.
- Spin columns can be used for the immunoliposome separation, and they are very fast method for purification. However, a large quantity of the samples are lost on the column. Dialysis is a slower process with minimal sample loss and therefore, we recommend dialysis over spin columns.
- If you are using a ligand or peptide that is hydrophobic then it is recommended to solubilize it in DMSO or DMF and then add the buffer to it. It is recommended not to use more than 5% volume of DMSO or DMF in the solution. DMF and DMSO are both compatible with liposomes and they are also miscible in water. Other organic solvent such as ethanol and chloroform are not compatible with liposomes and will cause the liposomes to lyse. If you end up using DMSO or DMF then after the conjugation reaction is done, you need to remove DMSO and DMF from the liposomes. In order to do that you need to use a dialysis cassette that is made from REGENERATED CELLULOSE MEMBRANE. NOTE: Not all membranes are compatible with DMF and DMSO. We recommend using a Slide-A-Lyzer™ MINI Dialysis Device with MWCO of 2K made from regenerated cellulose membrane manufactured by ThermoFisher. After DMSO or DMF is removed, you can use Float-A-Lyzer® dialysis device for the final step of cleaning up the prep.
- Liposomes should be kept at 4°C and NEVER be frozen.
Database
Direct link to the database page for easy navigation: Immunoliposomes Conjugation Database
Appearance
Immunosome®-DBCO is a white translucent liquid made of nano size unilamellar liposomes. Usually due to the small size of liposomes no settling will occur in the bottom of the vial. The liposomes are packaged in an amber vial.
Ordering/Shipping Information
- All liposome based formulations are shipped on blue ice at 4°C in insulated packages using overnight shipping or international express shipping.
- Liposomes should NEVER be frozen. Ice crystals that form in the lipid membrane can rupture the membrane, change the size of the liposomes and cause the encapsulated drug to leak out. Liposomes in liquid form should always be kept in the refrigerator.
- Clients who order from outside of the United States of America are responsible for their government import taxes and customs paperwork. Encapsula NanoSciences is NOT responsible for importation fees to countries outside of the United States of America.
- We strongly encourage the clients in Japan, Korea, Taiwan and China to order via a distributor. Tough customs clearance regulations in these countries will cause delay in custom clearance of these perishable formulations if ordered directly through us. Distributors can easily clear the packages from customs. To see the list of the distributors click here.
- Clients ordering from universities and research institutes in Australia should keep in mind that the liposome formulations are made from synthetic material and the formulations do not require a “permit to import quarantine material”. Liposomes are NOT biological products.
- If you would like your institute’s FedEx or DHL account to be charged for shipping, then please provide the account number at the time of ordering.
- Encapsula NanoSciences has no control over delays due to inclement weather or customs clearance delays. You will receive a FedEx or DHL tracking number once your order is confirmed. Contact FedEx or DHL in advance and make sure that the paperwork for customs is done on time. All subsequent shipping inquiries should be directed to Federal Express or DHL.
Storage and Shelf Life
Storage
Immunosome® products should always be stored at in the dark at 4°C, except when brought to room temperature for brief periods prior to animal dosing. DO NOT FREEZE. If the suspension is frozen, the encapsulated drug can be released from the liposomes thus limiting its effectiveness. In addition, the size of the liposomes will also change upon freezing and thawing.
Shelf Life
Immunosome®-DBCO is made on daily basis. The batch that is shipped is manufactured on the same day. It is advised to use the products within 4 months of the manufacturing date.
References and background reading
1. Simon M, Zangemeister-Wittke U, Plückthun A. Facile double-functionalization of designed ankyrin repeat proteins using click and thiol chemistries. Bioconjugate chemistry. 2012 Jan 20;23(2):279-86.
2. Baskin JM, Prescher JA, Laughlin ST, Agard NJ, Chang PV, Miller IA, Lo A, Codelli JA, Bertozzi CR. Copper-free click chemistry for dynamic in vivo imaging. Proceedings of the National Academy of Sciences. 2007 Oct 23;104(43):16793-7.
3. Marqués-Gallego P, de Kroon AI. Ligation strategies for targeting liposomal nanocarriers. BioMed research international. 2014 Jul 14;2014.
4. Debets MF, van Berkel SS, Schoffelen S, Rutjes FP, van Hest JC, van Delft FL. Aza-dibenzocyclooctynes for fast and efficient enzyme PEGylation via copper-free (3+2) cycloaddition. Chemical communications. 2010;46(1):97-9.
5. Agard NJ, Baskin JM, Prescher JA, Lo A, Bertozzi CR. A comparative study of bioorthogonal reactions with azides. ACS chemical biology. 2006 Oct 20;1(10):644-8.
6. Ma Y, Zhang H, Gruzdys V, Sun XL. Azide-reactive liposome for chemoselective and biocompatible liposomal surface functionalization and glyco-liposomal microarray fabrication. Langmuir. 2011 Oct 7;27(21):13097-103.
7. Xu J, Filion TM, Prifti F, Song J. Cytocompatible Poly (ethylene glycol)‐co‐polycarbonate Hydrogels Cross‐Linked by Copper‐Free, Strain‐Promoted Click Chemistry. Chemistry–An Asian Journal. 2011 Oct 4;6(10):2730-7.
8. Sletten EM, Bertozzi CR. Bioorthogonal chemistry: fishing for selectivity in a sea of functionality. Angewandte Chemie International Edition. 2009 Sep 7;48(38):6974-98.
9. Campbell‐Verduyn LS, Mirfeizi L, Schoonen AK, Dierckx RA, Elsinga PH, Feringa BL. Strain‐Promoted Copper‐Free “Click” Chemistry for 18F Radiolabeling of Bombesin. Angewandte Chemie International Edition. 2011 Nov 18;50(47):11117-20.
10. Jewett JC, Sletten EM, Bertozzi CR. Rapid Cu-free click chemistry with readily synthesized biarylazacyclooctynones. Journal of the American Chemical Society. 2010 Feb 26;132(11):3688-90.
11. Wang L, Jiang R, Liu Y, Cheng M, Wu Q, Sun XL. Recombinant and chemo-/bio-orthogonal synthesis of liposomal thrombomodulin and its antithrombotic activity. Journal of bioscience and bioengineering. 2017 Oct 1;124(4):445-51.
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
1、 配制JC-1染色工作液:
取适量JC-1 Stain (200×),按照每50μl JC-1 Stain (200×)加入8ml ddH2O的比例稀释JC-1,剧烈Vortex充分溶解并混匀JC-1。然后再加入2ml JC-1 Buffer(5×),混匀后即为JC-1染色工作液。6孔板每孔所需JC-1染色工作液的量为1ml,其它培养器皿的JC-1染色工作液的用量以此类推。
2、 设置阳性对照:
推荐CCCP(10mM)加入到细胞培养液中处理细胞。随后按照下述方法装载JC-1,进行线粒体膜电位的检测。对于特定的细胞,CCCP的作用浓度和作用时间可能有所不同,需自行参考相关文献资料确定。
3、对于悬浮细胞:
a. 取1~6×105细胞,重悬于0.5ml细胞培养液中,细胞培养液中可以含血清和酚红。
b. 加入0.5ml JC-1染色工作液,颠倒数次混匀。细胞培养箱中37℃孵育。
c. 在孵育期间,按照每1ml JC-1 Buffer(5×)加入4ml蒸馏水的比例,配制适量的JC-1 Buffer(1×),并放置于冰浴。
d. 37℃孵育结束后, 4℃ 600g离心3~4min,沉淀细胞。弃上清,注意尽量不要吸除细胞。
f. 再用JC-1 Buffer(1×)重悬后,用荧光显微镜或激光共聚焦显微镜观察,也可以用荧光分光光度计检测或流式细胞仪分析。
4、对于贴壁细胞:
注意:对于贴壁细胞,如果希望采用荧光分光光度计或流式细胞仪检测,应先收集细胞,重悬后参考悬浮细胞的检测方法。
a.吸除6孔板培养液,根据具体实验如有必要可以用PBS或其它适当溶液洗涤细胞一次,加入1ml细胞培养液。细胞培养液中可以含有血清和酚红。
b. 加入1ml JC-1染色工作液,充分混匀。细胞培养箱中37℃孵育。
c. 在孵育期间,按照每1ml JC-1 Buffer(5×)加入蒸馏水的比例,配制适量的JC-1 Buffer(1×),并放置于冰浴。
d. 37℃孵育结束后, 吸除上清,用JC-1 Buffer(1×)洗涤2次。
e. 加入2ml细胞培养液,培养液中可以含有血清和酚红。
f. 荧光显微镜或激光共聚焦显微镜下观察。
5、对于纯化的线粒体:
a. 把配制好的JC-1染色工作液再用JC-1 Buffer(1×)稀释5倍。
b. 0.9ml 5倍稀释的JC-1染色工作液中加入0.1ml总蛋白量为10~100μg纯化的线粒体。
c. 用荧光分光光度计或荧光酶标仪检测:混匀后直接用荧光分光光度计进行时间扫描,激发波长为485nm,发射波长为590nm。如果使用荧光酶标仪,激发波长不能设置为485nm时,可以在475~520nm范围内设置激发波长。另外,也可以参考下面步骤6中的波长设置进行荧光检测。
d. 用荧光显微镜或激光共聚焦显微镜观察:方法同下面的步骤6。
6、荧光观测和结果分析:
检测JC-1单体时可以把激发光设置为490nm,发射光设置为530nm;检测JC-1聚合物时,可以把激发光设置为525nm,发射光设置为590nm。出现红色荧光说明线粒体膜电位比较正常,细胞的状态也比较正常。
注意事项:
1、 JC-1 Stain(200×)应完全溶解混匀后使用,但应避免反复冻融。必须先把JC-1 Stain(200×)用ddH2O充分溶解混匀后,才可加入JC-1 Buffer(1×)。不可先配制JC-1 Buffer(1×)再加入JC-1 Stain(200×),否则导致JC-1很难充分溶解,严重影响后续的检测。
2、 对于6孔板中的样品,本试剂盒共可以检测100个样品;对于12孔中的样品,本试剂盒共可以检测200个样品。
3、 装载完JC-1后用JC-1 Buffer(1×)洗涤时,尽量使JC-1 Buffer(1×)保持4℃左右,此时的洗涤效果较好。
4、 勿把JC-1 Buffer(5×)全部配制成1×,因为操作过程中需直接使用JC-1 Buffer(5×)。
5、 如JC-1 Buffer(5×)中有沉淀,必须全部溶解后才能使用,为促进溶解可以在37℃加热。
6、 CCCP为线粒体电子传递链抑制剂,有一定毒性,请注意小心防护。
实验室要开展支原体检测,方法是PCR法,先要采购试剂盒,用过的同学给推荐一下好用的品牌呗
公司产品通过ISO9001质量体系认证
公司通过ISO14001环境体系认证
公司产品获得国家多项专利证书
公司产品获得计算机软件著作权
核心科技:自主品牌深芬仪器、中国制造、专利产品、技术保障
运输保证:优质EPE珍珠棉缓冲材料、牛皮瓦楞纸、免熏蒸木箱满足出口及国内运输要求。
售后保证:仪器免费保修一年,终身维护值得信赖!
牛胰岛素,是一种多肽
在1965年9月17日我国完成了结晶牛胰岛素的全合成。经过严格鉴定,它的结构、生物活力、物理化学性质、结晶形状都和天然的牛胰岛素完全一样。这是世界上第一个人工合成的蛋白质,为人类认识生命、揭开生命奥秘迈出了可喜的一大步。这项成果获1982年中国自然科学一等奖。
1953年,英国人F. SangerSanger由于测定了牛胰岛素的一级结构而获得1958年诺贝尔化学奖。