请使用支持JavaScript的浏览器! +,Fast and Efficient Antibody Purification using HCIC Technology蚂蚁淘商城
商品信息
联系客服
Bioclone/BcMag™ Quick Antibody Purification Kit/2 ml(Purify up to 10 mg IgG)/EA101
郑重提醒:
无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
Bioclone/BcMag™ Quick Antibody Purification Kit/2 ml(Purify up to 10 mg IgG)/EA101
品牌 / 
magnetic-beads
货号 / 
EA101
美元价:
(友情提示:该价格仅为参考,欢迎联系客服询价!)
数    量:
免费咨询热线
4000-520-616

Principle

The separation of antibodies from various biomasses can be accomplished using hydrophobic charge induction chromatography with 4-mercapto-ethyl-pyridine as the ligand. Binding is based on mild hydrophobic contact and is accomplished in near-physiological circumstances, without the use of salts. When the pH is reduced, the ligand and the antibody gain a net positive charge under mild acidic circumstances (pH 4.0-4.5).

Principle of Hydrophobic charge-induction chromatography (HCIC)

HCIC has several process advantages over more traditional antibody purification methods, such as protein A or ion exchange:

Sample preparation is reduced to scarification since feedstocks may be applied without ionic strength or pH adjustment.

Preconcentration of dilute samples is unnecessary because effective capture is accomplished even with feedstocks as dilute as 40μg of antibody per ml.

Gentle, pH-controlled elution with dilute buffer lowers the possibility of antibody aggregation at lower pH and avoids the requirement for IgG desalting or diafiltration.

Magnetic resins have significant advantages over traditional chromatography, such as column, agarose, or non-magnetic resin. The magnetic bead-based format enables rapid high-yield processing of 96 samples in about 20 minutes, achieving more than 90% purities and recoveries of more than 95% for various IgG species. When using column-based technologies, processing multiple samples in academic research labs may necessitate a significant quantity of hand pipetting. This pipetting can discourage differences in the yield of target biomolecules between experiments and people. Staff and students may require extensive training and practice to produce constant protein yields. It is due to the numerous benefits of magnetic resins, such as their ease of use, rapid experimental protocols, suitability, and convenience for high-throughput automated and miniaturized processing.

Workflow

The separation of antibodies present in complex mixtures using chromatography involves the antibodies binding the beads. After Binding, the beads are washed to remove non-antibody protein. Finally, the antibody was eluted from the beads.

Workflow of Quick antibody purification

Feature and Benefits

Efficient – recovery exceeds 85%, and purity exceeds 85%.

Fast purification – Fast and high-throughput procedure

Convenient – no columns, filters, or a laborious repeat of pipetting or centrifugation.

Amine – free buffer does not require removal or neutralization

Robust – effective for IgG subclasses that bind poorly to Protein A or G

Gentle – No harsh antibody elution conditions helps retain IgG activity

Regenerable – beads can be renewed and used for up to 3 purifications

PROTOCOL

Note:

The following protocol is an example of purifying antibodies from the serum.

The beads and sample volume can be rational Scale-up (or down).

Equipment

Item

Magnetic Rack for centrifuge tube


** Based on sample volume, the user can choose one of the following magnetic Racks

Source

•  BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

•  BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

•  BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

•  BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

Item

BcMag™ 96-well Plate Magnetic Rack.

Source

•  BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Item

Adjustable Single and Multichannel Pipettes

Item

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates / tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Eppendorf, Cat. No. 5353000529

Tube Holder PCR 96

Eppendorf, Cat. No. 022674005

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Eppendorf, Cat. No. 022674048

Smart Mixer, Multi Shaker

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR plates/tubes

** IMPORTANT! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates has to be ≥2.5mm.

Addition items are required if using 96-well micro-plates

Fisher Scientific™ Microplate Advanced Vortex Mixers

Fisher, Cat. No. 02-216-101

OHAUS Microplate Vortex Mixers

OHAUS, Cat. No. 30392160

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 800 rpm

Clear Flat-Bottom Non-Binding Assay Microplates

Items

Magnetic Rack for centrifuge tube

** Based on sample volume, the user can choose one of the following magnetic Racks

Source

BcMag™ Rack-2 for holding two individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-01)

BcMag™ Rack-6 for holding six individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-02)

BcMag™ Rack-24 for holding twenty-four individual 1.5-2.0 ml centrifuge tubes (Bioclone, Cat. No. MS-03)

BcMag™ Rack-50 for holding one 50 ml centrifuge tube, one 15 ml centrifuge tube, and four individual 1.5 ml centrifuge tubes (Bioclone, Cat. No. MS-04)

BcMag™ 96-well Plate Magnetic Rack

BcMa™ 96-well Plate Magnetic Rack (side-pull) compatible with 96-well PCR plate and 96-well microplate or other compatible Racks (Bioclone, Cat. No. MS-05)

Adjustable Single and Multichannel Pipettes

Centrifuge with Swinging Bucket

Addition items are required if using 96-well PCR plates/tubes

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 2000 rpm

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048

BenchTop Lab Systems, Cat. No. 5353000529

Eppendorf™ MixMate™

Tube Holder PCR 96

Tube Holder 1.5/2.0 mL, for 24 × 1.5 mL or 2.0 mL

Smart Mixer, Multi Shaker
 

Eppendorf, Cat. No. 5353000529

Eppendorf, Cat. No. 022674005

Eppendorf, Cat. No. 022674048
 

BenchTop Lab Systems, Cat. No. 5353000529

1.5/2.0 mL centrifuge tube

96-well PCR Plates or 8-Strip PCR Tubes

PCR plates/tubes

! IMPORTANT ! If using other tubes or PCR plates, make sure that the well diameter at the bottom of the conical section of PCR Tubes or PCR plates has to be ≥2.5mm.

Addition items are required if using 96-well microplates

Fisher Scientific™ Microplate Advanced Vortex Mixers

Fisher, Cat. No. 02-216-101

OHAUS Microplate Vortex Mixers

OHAUS, Cat. No. 30392160

Vortex Mixer

** The user can also use other compatible vortex mixers. However, the Time and Speed should be optimized, and the mixer should be: Orbit ≥1.5 mm-4 mm, Speed ≥ 800 rpm

Clear Flat-bottom Non-Binding Assay Microplates

Procedure

! Important !

The following protocol is optimized for the efficient clean-up of the 3μl serum sample. The procedure may need to be optimized if an alternative reaction scale is used.

Shake or vortex the bottle to completely resuspend the magnetic beads before using.

Do not allow the magnetic beads to sit for more than two minutes before dispensing.

A.

Sample preparation

1.

Dilute whole serum with an equal volume of 2x Binding/Wash Buffer and mix well.

B.

Magnetic Particles Preparation

1.

Shake the bottle to completely resuspend the magnetic particles.

2.

Transfer desired amount of magnetic particles to a centrifuge tube (Note: 1 ml of BcMag™ Quick Antibody Purification Magnetic particles per 0.5-1 ml of whole serum is recommended. The volumes can be scaled accordingly. IgG levels in serum are usually 10-15mg/ml). Place the tube on the magnetic rack for 1-3 minutes until the supernatant becomes clear. Remove the supernatant while the tube remains on the rack.

3.

Remove the tube and resuspend the beads with 10 beads volumes of 1x Binding/Wash buffer.

C.

Sample Binding

1.

Add the washed particles from step B.4 to the diluted sample from step A1. Completely resuspend the beads and leave them at room temperature for 10-30 minutes with end-over-end rotation.

2.

Place the tube on a magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack.

3.

Place the tube on the magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack. Remove the tube from the rack and wash the particles with 10 beads volumes of 1x Binding/Wash Buffer.

4.

Repeat step 3 five times

D.

IgG Elution

1.

Remove the tube from the rack and resuspend the particles with 10 beads volumes of Elution buffer to elute IgG. Place the tube on the magnetic rack for 1-3 minutes. Remove the supernatant while the tube remains on the rack.

Mini-scale high throughput purification

1.

Transfer 50μl beads (Step B4) to a new well of 96well PCR plate or 96-well microplates or 0.2ml PCR tube and add 20μl diluted serum from A1.

2.

Mix the beads with the sample by slowly pipetting up and down 25 times (one minute) or by vortex mixer for 5 minutes at 2000 rpm.

3.

Place the sample plate/ tube on the magnetic separation plate for 30 seconds or until the solution is clear.

4.

Discard the supernatant and wash the beads three times with 100 μl of 1x Binding/Wash Buffer using a magnetic rack.

5.

Add 50 μl of Elution buffer to elute the antibody by slowly pipetting up and down 25 times (one minute) or vortex mixer for 5 minutes at 2000 rpm.

6.

Place the sample plate/ tube on the magnetic separation plate for 30 seconds or until the solution is clear.

7.

Transfer the supernatant to a clean plate /tube while the sample plate remains on the magnetic separation plate. The sample is ready for downstream applications.

Additional information

Beads Regeneration

1.

If the bead has to be regenerated, add 10ml of 35 mM sodium phosphate; 30% n-propanol, pH 8.5 for 1 ml beads and mix the beads with the sample by slowly pipetting up and down 25 times. Place the sample plate/ tube on the magnetic separation plate for 30 seconds or until the solution is clear. Discard the supernatants.

2.

Repeat Step 1 five times.

3.

Wash the beads with 10 beads volumes of 1x Binding/Wash Buffer three times

4.

Resuspend the beads in 1x Binding/Wash Buffer and store at 4°C. The beads may be renewed three times without losing substantial selectivity.

Troubleshooting

Problem

The yield of the purified antibody is too low or undetectable

Probable Cause

Sample devoid of antibody

Suggestion

  • Ensure that the sample contains IgG by using another method, such as an ELISA or isotyping kit.

Problem

The yield of the purified antibody is too low or undetectable

Probable Cause

The antibody of interest bound to the beads

Suggestion

  • Ensure that the pH of the sample is between 8.5.

Problem

Observe multiple bands present on stained SDS-polyacrylamide gel

Probable Cause

The ratio of the beads and sample is not optimized.

Suggestion

  • Dialyze sample against 1x biding/wash buffer.
  • Optimize the ration of the beads and sample

Problem

A significant amount of antibodies was purified. However, no antibody of interest was found.

Probable Cause

The concentration of antibodies of interest is low.

Suggestion

  • Purify the antibody utilizing active affinity magnetic beads and a specific antigen.

Problem

Probable Cause

Suggestion

The yield of the purified antibody is too low or undetectable

Sample devoid of antibody

  • Ensure that the sample contains IgG by using another method, such as an ELISA or isotyping kit.

The antibody of interest bound to the beads

  • Ensure that the pH of the sample is around 8.5.

Observe multiple bands present on stained SDS-polyacrylamide gel


The ratio of the beads and sample is not optimized.
 

  • Dialyze sample against 1x biding/wash buffer.
  • Optimize the ration of the beads and sample

A significant amount of antibodies was purified. However, no antibody of interest was found.


The concentration of antibodies of interest is low.
 
  • Purify the antibody utilizing active affinity magnetic beads and a specific antigen.

Learn More

Instruction Manual

MSDS

Related Antibody Magnetic Beads →

General Reference

1.

Li M, Zhang Q, Lin D, Yao S. Development and application of hydrophobic charge-induction chromatography for bioseparation. J Chromatogr B Analyt Technol Biomed Life Sci. 2019 Dec 15;1134-1135:121850.

2.

Zhao G, Sun Y. Displacement chromatography of proteins on hydrophobic charge induction adsorbent column. J Chromatogr A. 2007 Sep 21;1165(1-2):109-15.

3.

Boschetti E. Antibody separation by hydrophobic charge induction chromatography. Trends Biotechnol. 2002 Aug;20(8):333-7.

4.

Gomes CS, Fashina A, Fernández-Castané A, Overton TW, Hobley TJ, Theodosiou E, Thomas OR. Magnetic hydrophobic-charge induction adsorbents for the recovery of immunoglobulins from antiserum feedstocks by high-gradient magnetic fishing. J Chem Technol Biotechnol. 2018 Jul;93(7):1901-1915.

5.

Hirano A, Maruyama T, Shiraki K, Arakawa T, Kameda T. A study of the small-molecule system used to investigate the effect of arginine on antibody elution in hydrophobic charge-induction chromatography. Protein Expr Purif. 2017 Jan;129:44-52.

蚂蚁淘电商平台
ebiomall.com
公司介绍
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
柏业贸易(上海)有限公司在发布的核糖核酸酶 RNase A供应信息,浏览与核糖核酸酶 RNase A相关的产品或在搜索更多与核糖核酸酶 RNase A相关的内容。 查看更多>
作为一种通用酶,核糖核酸酶P(RNase P)是一种通用核酶,已在生命的三个王国中发现。它加工tRNA前体(pre-tRNA)的5端。RNase P是一种核糖核蛋白复合物,由单个具有催化能力的RNA组分和可变数量的蛋白组成。与仅含有一种小蛋白辅因子的细菌RNase P不同的是,古细菌RNase P和真核生物细胞核中的RNase P已进化出相当复杂的蛋白亚基:古细菌中有5种蛋白亚基,真核生物中有9~10种。这种tRNA前体加工反应可通过包括四个不同事件的动力学反应机制来加以描述:(1)R 查看更多>
核糖核酸酶保护实验(Ribonuclease protection assay,RPA)是近十年发展起来的一种全新的mRNA定量分析方法。其基本原理是将标记的特异RNA探针(32P或生物素)与待测的RNA样品液相杂交,标记的特异RNA探针按碱基互补的原则与目的基因特异性结合,形成双链RNA;未结合的单链RNA经RNA酶A或RNA酶T1消化形成寡核糖核酸,而待测目的基因与特异RNA探针结合后形成双链RNA,免受RNA酶的消化,故该方法命名为RNA酶保护实验。对于32P标记的探针,杂交双链进行变性聚丙酰胺凝胶 查看更多>
PNAS:科学家制备双重核酸酶让CRISPR技术更上一层楼最近,美国西安大略大学的研究人员,就像玩分子乐高游戏一样,向革命性的新基因编辑工具CRISPR/Cas9添加了一种工程酶。他们的研究发表在12月12日出版的美国国家科学院院刊PNAS,表明他们添加的这种工程酶,使得CRISPR基因编辑技术能够更有效和有特异性地靶定基因。CRISPR为人类基因编辑提供的广阔前景,令科学界沸腾,从而打开了用基因疗法治疗囊性纤维化和白血病等疾病的可能性... 查看更多>
南京道斯夫生物科技有限公司在发布的去氧核糖核酸酶供应信息,浏览与去氧核糖核酸酶相关的产品或在搜索更多与去氧核糖核酸酶相关的内容。 查看更多>
北京博迈斯科技发展有限公司在发布的DNase I脱氧核糖核酸酶I供应信息,浏览与DNase I脱氧核糖核酸酶I相关的产品或在搜索更多与DNase I脱氧核糖核酸酶I相关的内容。 查看更多>
amresco去除核酸酶喷剂【1218】,amresco现货。Amresco公司来自美国,成立于 1976 年,为高质量生化试剂 / 试剂盒的生产商及供应商,产品服务于生物科研领域。用于体外诊断及医药中间体的美国 FDA 注册。amresco去除核酸酶喷剂【1218】021-61806666 33779006品牌:AMRESCO数量:大量保存条件:4℃供应商:AMRESCO保质期:1年amresco去除核酸酶喷剂【1218】CodeIt 查看更多>
上海优予生物科技有限公司在发布的9001-99-4核糖核酸酶A(美仑);RNase A;核糖核酸酶I供应信息,浏览与9001-99-4核糖核酸酶A(美仑);RNase A;核糖核酸酶I相关的产品或在搜索更多与9001-99-4核糖核酸酶A(美仑);RNase A;核糖核酸酶I相关的内容。 查看更多>
小鼠抗磷脂抗体(apa)elisa试剂盒使用注意事项:1.[jl40314] 小鼠抗磷脂抗体(apa)elisa试剂盒检测前,检查各种仪器, 查看更多>
上海如吉生物科技发展有限公司在发布的核糖核酸酶A(牛胰)RNAase A供应信息,浏览与核糖核酸酶A(牛胰)RNAase A相关的产品或在搜索更多与核糖核酸酶A(牛胰)RNAase A相关的内容。 查看更多>
去除核酸酶纸巾产品名称:去除核酸酶纸巾产品简介:上海通善生物是去除核酸酶纸巾最权威的供应商,提供报价,咨询,技术服务,欢迎来电021-61806666咨询选购。产品库存:现货。产品价格:询价。供 应 商:通善生物。供应商地址:上海市闵行区金平路788弄166号。去除核酸酶纸巾说明书:去除核酸酶纸巾其它信息:货号产品名称级别K610-1L0.1X SSC BUFFER WITH 0.2% SDS超纯级K611-1L0.1X SSPE BU 查看更多>
常见问题
蚂蚁淘所售产品均为正品吗?
蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
下单后可以修改订单吗?
未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
商品几天可以发货?
现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
订单如何取消?
如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
可以开发票吗?
本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
如何联系商家?
蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
收到的商品少了/发错了怎么办?
同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
退换货/维修需要多长时间?
一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
商品咨询