

Cell culture contamination control: Detection
Detection and identification of Mycoplasma
Venor®GeM-qEP Mycoplasma Detection Kit
Venor®GeM qEP utilizes quantitative, real-time PCR (qPCR). The kit can be performed with any type of real-time PCR cycler able to detect the fluorescence dyes FAM™ and HEX™. The protocol provided is preferred for fast and reliable screening of cell culture supernatants most applicable in research and development. The detection procedure can be performed within 3 hours.Important note: Please see the note section for important information on the use of the supplied positive control
Minerva Biolabs
Catalogue No. | Description | Pack Size | Price | Qty |
|
---|---|---|---|---|---|
11-9025 | Venor®GeM qEP | 25 rxns | £283.00 | Quantity | Add to Order |
11-9100 | Venor®GeM qEP | 100 rxns | £933.00 | Quantity | Add to Order |
11-9250 | Venor®GeM qEP | 250 rxns | £1,894.00 | Quantity | Add to Order |
11-9905 | Internal Control DNA extra for VenorGem qEP | 4 vials | £19.00 | Quantity | Add to Order |
Venor®GeM-qEP Mycoplasma Detection Kit
Venor®GeM qEP utilizes quantitative, real-time PCR (qPCR). The kit can be performed with any type of real-time PCR cycler able to detect the fluorescence dyes FAM™ and HEX™. The protocol provided is preferred for fast and reliable screening of cell culture supernatants most applicable in research and development. The detection procedure can be performed within 3 hours.Important note: Please see the note section for important information on the use of the supplied positive control
Minerva Biolabs
Venor®GeM qEP
Mycoplasmas are specifically detected by amplifying a highly conserved rRNA operon, or more specifically, the 16S rRNA coding region in the mycoplasma genome. The mycoplasma-specific amplification is detected at 520 nm (FAM™ channel).The kit includes primer and FAM™ labeled probes which allow the specific detection of all Mollicutes species so far described as contaminants of cell cultures and media components. Eukaryotic DNA is not amplified by this primer/probe system. False negative results due to PCR inhibitors or improper DNA extraction are detected by the internal amplification control which can be added to the PCR master mix. The amplification of the internal amplification control is detected at 610 nm (HEX™ channel).
Important note:
Please see the note section for important information on the use of the supplied positive control
Type of PCR
TaqMan® basedqPCR Assay with FAM™ and HEX™ labeled probes
Recommended Use / Scope
Venor®GeM qEP is used for direct detection of Mollicutes (Mycoplasma, Acholeplasma, Spiroplasma) contamination in cell cultures and cell media components.
Kit Components
lyophilized primer/nucleotide/probe/polymerase/mix in aliquots of 25 tests rehydration bufferlyophilized internal amplification control lyophilized positive control PCR grade water
Package Sizes
- Cat. No. 11-9025 25 tests
- Cat. No. 11-9100 100 tests
- Cat. No. 11-9250 250 tests
Result Evaluation
cycler based, real-time PCR
Required Consumables
PCR reaction tubes Optional for process validation and EP 2.6.7 compliant testing: Internal Control DNA extra (4 vials for 300 µl each of internal amplification control; Cat. No. 11-9905) 10CFU™ Sensitivity Standards available for all EP2.6.7 listed mycoplasma species
Required Lab Devices
qPCR cycler with FAM™ and HEX™ filter variable microliter pipettes benchtop centrifuge for 1.5 ml reaction tubes
Shelf Life and Storage
Components can be stored at2 to8 °C for at least 12 months. After rehydration the reagents must be stored at -18 °C.
EP 2.6.7 Compliance
Yes.Please note that validation data are provided for information purpose only. EP 2.6.7 clearly states “Where commercial kits are used …, documented validation points already covered by the kit manufacturer can replace validation by the user. Nevertheless, the performance of the kit with respect to its intended use has to be demonstrated by the user (e.g. detection limit, robustness, cross-detection of other classes of bacteria.”. Please feel free to contact us if you need further assistance.
Fig. Amplified dilution series of Mycoplasma fermentans, performed on a Corbett RotorGene®6000.
If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200
Venor®GeM-qEP Mycoplasma Detection Kit
Venor®GeM qEP utilizes quantitative, real-time PCR (qPCR). The kit can be performed with any type of real-time PCR cycler able to detect the fluorescence dyes FAM™ and HEX™. The protocol provided is preferred for fast and reliable screening of cell culture supernatants most applicable in research and development. The detection procedure can be performed within 3 hours.Important note: Please see the note section for important information on the use of the supplied positive control
Minerva Biolabs
Venor®GeM qEP protocol
Quick Visual Protocol
Please note: all protocols off site are the responsibility of the products supplier
If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200
Venor®GeM-qEP Mycoplasma Detection Kit
Venor®GeM qEP utilizes quantitative, real-time PCR (qPCR). The kit can be performed with any type of real-time PCR cycler able to detect the fluorescence dyes FAM™ and HEX™. The protocol provided is preferred for fast and reliable screening of cell culture supernatants most applicable in research and development. The detection procedure can be performed within 3 hours.Important note: Please see the note section for important information on the use of the supplied positive control
Minerva Biolabs
For a list of citations please click here
If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200
Venor®GeM-qEP Mycoplasma Detection Kit
Venor®GeM qEP utilizes quantitative, real-time PCR (qPCR). The kit can be performed with any type of real-time PCR cycler able to detect the fluorescence dyes FAM™ and HEX™. The protocol provided is preferred for fast and reliable screening of cell culture supernatants most applicable in research and development. The detection procedure can be performed within 3 hours.Important note: Please see the note section for important information on the use of the supplied positive control
Minerva Biolabs
Important notes on the use postive controls in the VenorGem™ QEP kit
The Positive Control comes in one vial. After rehydration, this reagent is stable for frequent thawing/freezing cycles. However we strongly recommend that customers use DNase-free pipette tips and a clean surrounding. One bacteria particle contaminating the reagent is able to digest all the DNA during the thawing phase.
Aliquoting the rehydrated Positive Control can help avoid this as long as the following criterion are met: 1. Make aliquots in PCR tubes (they are usually clean, DNase-free, low-binding tubes, low surface area). 2. Never ever use reaction tubes or other larger vials, as they absorb the minute amounts of DNA 3. keep the thawing time short. Freeze asap.
Required consumables:
PCR reaction tubes
Optional for process validation and EP 2.6.7 compliant testing:
Internal Control DNA extra (4 vials for 300 µl each of internal amplification control; Cat. No. 11-9905)
10CFU™ Sensitivity Standards available for all EP listed mycoplasma species
Required lab devices:
qPCR cycler with FAM™ and ROX™ filter
variable microliter pipettes
benchtop centrifuge for 1.5 ml reaction tubes
Shelf life and storage:
Components can be stored at2 to8 °C for at least 12 months. After rehydratisation the reagents must be stored at -18 °C.
EP 2.6.7 Compliance:
Yes.
Please note that validation data are provided for information purpose only. EP 2.6.7 clearly states “Where commercial kits are used …, documented validation points already covered by the kit manufacturer can replace validation by the user. Nevertheless, the performance of the kit with respect to its intended use has to be demonstrated by the user (e.g. detection limit, robustness, cross-detection of other classes of bacteria.”. Please feel free to contact us if you need further assistance.
If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200
Venor®GeM-qEP Mycoplasma Detection Kit
Venor®GeM qEP utilizes quantitative, real-time PCR (qPCR). The kit can be performed with any type of real-time PCR cycler able to detect the fluorescence dyes FAM™ and HEX™. The protocol provided is preferred for fast and reliable screening of cell culture supernatants most applicable in research and development. The detection procedure can be performed within 3 hours.Important note: Please see the note section for important information on the use of the supplied positive control
Minerva Biolabs
If you cannot find the answer to your problem below then please contact us or telephone 01954 210 200
AthensResearch&Technology公司位于美国乔治亚州雅典市,从1986年以来一直致力于纯化高纯度,高活性的人类蛋白质和开发这些蛋白的多克隆抗血清。我们的常规产品包括丝氨酸蛋白酶、蛋白酶抑制剂、中性粒细胞酶、载脂蛋白、脂蛋白,血小板蛋白、转铁蛋白、免疫球蛋白等。二十年多年来,世界各地的研究人员都在使用我们公司的产品。在炎症、冠状动脉疾病、自身免疫性疾病、癌症、老年痴呆症等等研究的主要科学出版物中都能看到引用我们公司的产品。我们提供优质,可靠的产品和出色的客户服务。我们期待着您的业务。如果需要定制研究服务,AthensResearch&Technology公司能够根据您的项目要求提供无与伦比的试剂。
公司主要产品:一、凝血因子相关系列产品:包括多款从人血浆、血小板中分离纯化的凝血因子相关蛋白。二、酶及抑制剂系列产品:包括多款从人血浆、红细胞分离纯化的a-抗糜蛋白酶、a1/2抗胰蛋白酶、抗凝血酶、C1酯酶抑制因子、Calpain-1等酶及其抑制剂产品。三、免疫球蛋白系列产品:包括多款从人血浆、骨髓瘤、初乳以及狗和小鼠血浆中分离纯化的免疫球蛋白产品。四、脂蛋白及载脂蛋白系列产品:包括包括多款从人血浆中分离纯化的载脂蛋白及脂蛋白(高密度、中等密度、低密度、极低密度脂蛋白)产品。五、低内毒素蛋白系列产品:包括多款适宜于细胞培养的低内毒素脂蛋白、免疫球蛋白及转铁蛋白产品。六、乳蛋白系列产品:包括从人乳中分离纯化的乳白蛋白、乳铁传递蛋白及分泌型免疫球蛋白A。七、中性粒细胞源蛋白系列产品:包括多款纯化分离自人中性粒细胞的Azurocidin 、CathepsinG及Lactoferrin等蛋白产品。八、血小板相关系列产品:包括纯化分离自人血小板的血小板因子4及凝血酶致敏蛋白。九、转铁蛋白及脱铁转铁蛋白(APOTRANSFERRINS)系列产品:包括多款纯化分离自人、大小鼠、狗及食蟹猴血浆中的转铁蛋白/脱铁转铁蛋白,可应用于细胞或组织培养。十、抗体系列产品:包括多款兔、大鼠、羊源的多克隆抗体产品。
ebiomall.com







