请使用支持JavaScript的浏览器! Qiagen/Rapid Capture System/6000-3101_蚂蚁淘,【正品极速】生物医学科研用品轻松购|ebiomall 蚂蚁淘商城
商品信息
联系客服
Qiagen/Rapid Capture System/6000-3101
郑重提醒:
无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
Qiagen/Rapid Capture System/6000-3101
品牌 / 
Qiagen
货号 / 
6000-3101
美元价:
(友情提示:该价格仅为参考,欢迎联系客服询价!)
数    量:
免费咨询热线
4000-520-616

Rapid Capture System

Product picture
For high-throughput Hybrid Capture 2 (HC2) assays
  • Streamlines digene HC2 High-Risk HPV and HC2 CT/GC DNA tests
  • Significant increase in labor savings
  • Decreases turn-around time for delivering results to physicians
  • Enables the laboratory to increase testing capacity
The Rapid Capture System is a semi-automated pipetting and microplate handling system for high-volume sample-throughput testing. This system handles up to 352 specimens and 1 to 4 platesin a single8 hour shift. The Rapid Capture System fits on a standard bench top andis compatible withsoftware that providesLIS interface connectivity.
  • Buy Products
  • Product Details
  • Service Plans
  • Product Resources

Buy Products

Cat No./ID:6000-3101
Rapid Capture System
Inquire
Rapid Capture System for high-volume sample throughput.
Cat No./ID:9001931
HC2 RCS Complete Instrument Package
Inquire
Complete system for high-volume sample throughput, including: Rapid Capture System, Vortexer, Racks, Microplate Luminometer, and validated PC System Package
Cat No./ID:9001932
HC2 RCS Upgrade Instrument Package
Inquire
Upgrade package for existing HC2 customers, including: installation of Rapid Capture System and HC2 System on existing validated hardware

The Rapid Capture System is intended to be used only in combination with QIAGEN Kits indicated for use with Rapid Capture System for applications described in the respective QIAGEN Kit handbooks.

Product Details

9
In vitro diagnostic device.
Performance

The Rapid Capture System (RCS) is FDA-approved (see IVD mark) for use with the digene HC2 High-Risk HPV DNA Test, digene HC2 CT/GC DNA Test, digene HC2 CT-ID DNA Test, and the digene HC2 GC-ID DNA Test. The system processes cervical samples collected in Specimen Transport Medium (STM), which is part of the digene Cervical Sampler. Other digene tests or sample types may be available for use on the RCS, depending on country regulations.

Onboard reagent stability 

The RCS provides reagent stability of 16 hours for those reagents most likely to be subject to extended onboard placement — Probe Mix, Detection Reagent 1, Detection Reagent 2, and the Capture Plates (see table).

Agreement of calibrator and control results of fresh vs. aged reagents
Overall agreementPositive agreementNegative agreementR2SlopeInterceptKappa
100% 96/97 (97.97–100)100% 64/64 (97.97–100)100% 32/32 (97.97–100)0.99360.970.471.0
The assay performance of reagents was evaluated using freshly prepared reagents vs. reagents that were aged onboard the Rapid Capture System platform at room temperature for a period of 16 hours to simulate 2 work shifts in a laboratory setting. Simulated clinical specimens were tested using 2 Rapid Capture Systems each on 2 days (RCS 1: aged reagents on day 1 and fresh reagents on day 2; RCS 2: fresh reagents on day 1 and aged reagents on day 2). Results were comparable for fresh vs. aged reagents (CI: 95%), indicating that reagents are sufficiently stable when placed onboard the instrument for a period of up to 16 hours.
Agreement of Rapid Capture System vs. manual HPV test methods 

The Rapid Capture System HPV application results show agreement with the manual method in clinical specimens. Statistical agreement was shown for cervical specimens collected in ThinPrep PreservCyt solution and STM (see tables).

RCS vs. manual HPV test method: STM patient specimen data (n=1001)
Cyt. class.HPV preval. %Overall + agreement % (n/N)Strong + region (>2.5)Overall – agreement % (n/N)Strong – region (<0.8)
WNL <30 years21%99.3% (139/140) 96.1, 10099.1% (112/113) 95.2, 10099.3% (538/542) 98.1, 99.8100% (531/531) 99.3, 100
WNL 30+ years15%92.0% (23/25)96.1, 10093.8% (15/16)69.8, 99.8100% (143/143) 97.5, 100100% (142/142) 97.4, 100
ASC-US65%98.1% (51/52)89.7, 100100% (47/47)92.4, 10096.4% (27/28) 81.7, 99.9100% (26/26) 86.8, 100
LSIL+96%100% (65/65) 94.5, 100100%(62/62) 94.2, 10066.7% (2/3) 9.4, 99.266.7% (2/3) 9.4, 99.2
Other33%100% (1/1)    2.5, 100100% (1/1)    2.5, 100100% (2/2)   15.8, 100100% (2/2)   15.8, 100
All STM28%98.6% (279/283) 96.4, 99.699.2% (237/239) 97.0, 99.999.2% (712/718) 98.2, 99.799.9% (703/704) 99.2, 100
Clinical results using the Rapid Capture System were compared with results obtained using the manual method in a multicenter study (N=2270 patients). Patient specimens were collected from 5 collection sites and testing was performed at 3 external sites. The data set consisted of cervical specimens collected in ThinPrep PreservCyt Solution (1269) and Specimen Transport Medium (1001). Confidence interval=95%. LSIL+: low-grade squamous intraepithelial lesion or greater; +: positive; –: negative; ASC-US: atypical squamous cells of undetermined significance; STM: Specimen Transport Medium; WNL: within normal limits.

 

RCS vs. manual HPV test method ThinPrep PreservCyt clinical specimen data (n=1269)
Cyt. classHPV preval. %Overall + agreement %  (n/N)Strong + region (>2.5)Overall agreement % (n/N)Strong – region (<0.8)
WNL <30 years20%96.2% (75/78) 89.2, 99.2100% (64/64) 94.4, 10098.4% (301/306) 96.2, 99.599.0% (293/296) 97.1, 99.8
WNL 30+ years8%88.7 (47/53) 77.0, 95.792.1% (35/38) 78.6, 98.399.1% (578/583) 98.0, 99.799.5% (571/574) 98.5, 99.9
ASC-US36%100% (48/48) 92.6, 100100% (46/46) 92.3, 10096.6% (84/87) 90.3, 99.396.5% (83/86) 90.1, 99.3
LSIL+77%100% (64/64) 94.4, 100100% (62/62) 94.2, 10089.5% (17/19) 66.9, 98.788.9% (16/18) 65.3, 98.6
Other11%100% (3/3) 29.2, 100100% (3/3) 29.2, 100100% (24/24) 85.6, 100100% (24/24) 85.8, 100
All PreservCyt Clinical20%96.4% (238/247) 93.2, 98.398.6% (211/214) 96.0, 99.798.5% (1007/1022) 97.6, 99.298.9% (990/1001) 98.0, 99.4
Clinical results using the Rapid Capture System were compared with those obtained with the manual method in a multicenter study (N=2270 patients). Patient specimens were collected from 5 collection sites, with testing performed at 3 external sites. The data set consisted of cervical specimens collected in ThinPrep PreservCyt Solution (1269) and Specimen Transport Medium (1001). In the results for the ThinPrep PreservCyt Solution, cytology data was unavailable from 4 patients. Confidence interval = 95%. LSIL+: low-grade squamous intraepithelial lesion or greater; +: positive; : negative; ASC-US: atypical squamous cells of undetermined significance; WNL: within normal limits.
Principle

The Rapid Capture System reduces repetitive manual steps, with technology that performs semi-automated assays. The system is designed to work with the Hybrid Capture 2 screening technology, and it is the only high-throughput system for testing cervical samples with the FDA-approved digene HC2 High-Risk HPV DNA Test. The Rapid Capture system provides the flexibility of multiple software scripts, allowing laboratories to adjust their schedules to improve workflow.

Specimen contamination or carryover of residual alkaline phophotase is minimized through the use of disposable pipette tips for reagent and specimen aspiration. The system automates sample transfers (from sample tubes to hybridization plate, then from hybridization plate to Capture Plate), plate handline, precision reagent pipetting with liquid level-sensing tips, incubation at ambient and 65°C temperatures, and washing.

Procedure
Multiple assays for flexible workflows

The Rapid Capture System (RCS) accommodates multiple assays or sample types during a single run — enabling scheduling flexibility. For instance, when running a single run of the digene HC2 High-Risk HPV DNA Test on the RCS, separate plates can handle both liquid based cytology (LBC) samples and digene cervical samples.

The Rapid Capture System can be used with the digene HC2 High-Risk HPV DNA Test, digene HC2 CT-ID DNA test, and digene HC2 GC-ID DNA Test. Depending on the test, the specimens can be collected using the digene Cervical Sampler, Specimen Transport Medium (STM), digene Female Swab Specimen Collection Kit, and PreservCyt solution.

High-throughput design for optimized workflow

The Rapid Capture System performs up to 352 tests/8 hours, automating 6 procedural steps of the manual method:

  • Specimen pipetting
  • Regent dispensing
  • Microplate handling
  • Microplate mixing
  • Microplate incubation
  • Microplate washing

User intervention is limited to specimen preparation, loading of specimen racks onto the deck, deck setup, chemiluminescent signal detection, and result reporting. Denaturation of the specimens in preparation for testing with the digene HC2 DNA Tests is performed independently of the Rapid Capture System. In addition, amplified chemiluminescent signal detection and result reporting are performed using the offline DML 2000/3000 Instrument and using the digene Hybrid Capture System Version 2 (DHCS v.2) Software.

The Rapid Capture System is intended to be used only in combination with QIAGEN kits indicated for use with the Rapid Capture System for applications described in the kit handbooks.

Applications

A range of digene HC2 DNA Tests enable high-throughput detection of pathogens using the Rapid Capture System. Using kits for Hybrid Capture applications, the Rapid Capture System automates detection of:

  • High-risk human papillomavirus (HPV) infection
  • Chlamydia trachomatis (CT) infections
  • Neisseria gonorrhoeae (GC) infections
Software

The HC2 System Software reports qualitative assay results with a user-friendly interface. Software supports customizable report formats — sorted by plate or specimen, with summary or detailed outputs. All results are tracked by the user ID for auditing and QA. The Rapid Capture System ScriptSelect Software allows users to choose the appropriate protocol and number of tests being run.

The HC2 System Software is compatible with multiple types of bar codes, which saves time and reduces manual entry errors. The software fully interfaces with Laboratory Information Systems (LIS), through which designated users can send patient and QC data to the laboratory network.

Service Plans

Cat No./ID:9243231
RCS, Full Agreement
Inquire

On-site QIAsymphony RGQ instrument repair, including travel, labor and parts, for a period of one year. Response time of two business days. Includes one Preventive Maintenance or Inspection Service during the Full Agreement period.

Cat No./ID:9243550A
RCS, Preventive Subscription
Inquire

One on-site Preventive Maintenance or Inspection Service visit for the Rapid Capture System, including travel, labor and parts. Includes a 10% discount on repair services during the Preventive Subscription period.

The Rapid Capture System is intended to be used only in combination with QIAGEN Kits indicated for use with Rapid Capture System for applications described in the respective QIAGEN Kit handbooks.

Product Resources

fragment fix placeholder
蚂蚁淘电商平台
ebiomall.com
公司介绍
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
常见问题
蚂蚁淘所售产品均为正品吗?
蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
下单后可以修改订单吗?
未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
商品几天可以发货?
现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
订单如何取消?
如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
可以开发票吗?
本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
如何联系商家?
蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
收到的商品少了/发错了怎么办?
同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
退换货/维修需要多长时间?
一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
商品咨询