AmplideX® PCR/CE SMN1/2 Plus Kit

Copy number variations in SMN1 and SMN2 are, respectively, associated with the onset and severity of spinal muscular atrophy (SMA), a debilitating and life-threatening illness of the central nervous system. Recent studies have demonstrated that transmission risk and disease severity may be impacted by the presence of additional variants, such as SMN1 gene duplication events and disease modifier in SMN2.

The AmplideX® PCR/CE SMN1/2 Plus Kit* revolutionizes the analysis of these two genes by delivering comprehensive results in less than four hours. Powered by AmplideX technology, the assay accurately quantifies SMN1 and SMN2 exon 7 copy number and also detects SMN1 gene duplication and SMN2 disease modifier variants – all from a single reaction. The assay shares a common workflow with other assays in the AmplideX product portfolio and is optimized for use on widely established laboratory equipment.

Features & Benefits

Reduced Complexity
  • Similar workflow to AmplideX PCR/CE FMR1*† kit eases implementation and training
  • Multiplexed, scalable design allows analysis of single-nucleotide variants, small indels, and copy-number changes from a single PCR reaction
  • Assay-specific software automates variant calls and streamlines data analysis
Optimized Workflow
  • DNA-to-data in less than four hours with only 60 minutes of hands-on-time
  • Optimized for use on commonly installed CE equipment
  • Fully-kitted solution sourced from a single vendor
Quality Results
  • Ability to differentiate between 0, 1, 2, 3 and ≥4 copies for both SMN1 and SMN2
  • Automated variant and copy-number genotyping
  • Accuracy demonstrated through comparisons with multiple orthogonal methods

Download Brochure

*For Research Use Only. Not for use in Diagnostic procedures.

Analytical Performance

  • Automated reporting of SMN1/2 copy number and variant detection via AmplideX Reporter Software (Figure 1)
  • DNA to data in less than four hours – all from a single PCR reaction (Figure 2)
  • Excellent concordance of SMN1 and SMN2 copy number results to sites’ in-house methods for over 500 replicates (Figure 3)
  • High assay specificity permits detection of SMN1–SMN2 hybrid peaks, including those resulting from gene conversion events (Figure 4)
  • 100% agreement between Sanger sequencing and PCR/CE SMN1/2 Plus Kit for detection of SMN1 gene duplication and SMN2 disease modifier variants (Figure 5).

Figure 1. Example Electropherogram Output – AmplideX PCR/CE SMN1/2 Plus Kit

Figure 2. AmplideX PCR/CE SMN1/2 Plus Kit Testing Workflow

Figure 3. Reproducibility of SMN1 and SMN2 copy number reporting across sites for over 500 replicates.

Figure 4. Detection and differentiation of SMN1 and SMN2 hybrid peaks.

Figure 5. Agreement between AmplideX PCR/CE SMN1/2 Plus Kit and Sanger sequencing for SMN1 gene duplication and SMN2 disease modifier variants

Additional Resources

Videos

View poster

View poster

From Two Days to Four Hours: How the AmplideX PCR/CE SMN1/2 Plus Kit Provides SMN1 and SMN2 Copy Number Information and More…

Posters

A Rapid Diagnostic and Screening System for Spinal Muscular Atrophy that Reports Copy Number Changes, Single Nucleotide Variants and Small IndelsView Full Poster

Ordering Information

Product NameNumber of ReactionsCatalog Number
AmplideX® PCR/CE SMN1/2 Plus Kit (RUO)50A00050
AmplideX® PCR/CE SMN1/2 Plus Kit (RUO)100A00054

T 1-877-777-1874; 512-681-5200 F 512-681-5202 E orders@asuragen.com

View Sales Contacts

AmplideX® SMA Plus Kit

The AmplideX® SMA Plus Kit* is an in vitro nucleic acid amplification kit intended to aid in the screening of carriers for and diagnosis of spinal muscular atrophy (SMA). The kit quantifies the number of copies of exon 7 of both SMN1 and SMN2 reported as 0, 1, 2, 3, or ≥ 4 genomic copies. The kit is designed for PCR with extracted genomic DNA from human whole blood performed on standard laboratory-validated thermal cyclers, followed by resolution on a general laboratory-validated genetic analyzer or capillary electrophoresis (CE) platform.  Additionally, the kit identifies chimeric genes with both SMN1 and SMN2 sequences, and detects variants SMN1 c.*3+80T>G and SMN1 c.*211_*212del, which are associated with SMN1 gene duplication and “silent carrier” status, as well as variant SMN2 c.859G>C, which is associated with a milder disease phenotype.

Disease Background

  • General Information
    • SMA is a debilitating illness resulting from the deficient production of motor neurons in the central nervous system and is a leading genetic cause of infant death.
    • It is transmitted via an autosomal recessive inheritance pattern
  • Diagnosing SMA
    • SMA is diagnosed when no functional copies of the SMN1 gene are present
    • Disease severity is inversely correlated to the number of SMN2 copies present
    • Life-saving treatments must be started early, so rapid delivery of diagnostic test results is critical
  • Carrier Screening
    • Approximately 1 in 50 individuals is a carrier of SMA
    • clinical advisory committees (American College of Medical Genetics (ACMG), American College of Obstetrics and Gynecology (ACOG)) recommend screening be available to all couples regardless of ethnicity

Features & Benefits

Reduced ComplexityEase of data analysis and reporting

  • One kit to identify SMA patients, carriers (including detection of variants associated with silent carriers), and refine disease prognosis – all from a single PCR reaction
  • Similar workflow to AmplideX PCR/CE FMR1*† kit eases implementation and training
  • Assay-specific software automates results reporting and streamlines data analysis

Optimized WorkflowReduces valuable operator hands-on-time and overall turnaround time

  • Diagnostic and screening results are reported in less than four hours with only 60 minutes of hands-on-time
  • Scalable workflow supports high sample throughput testing
  • Optimized for use on widely installed CE equipment
  • Fully-kitted solution sourced from a single vendor

Quality PerformanceComprehensive analysis of SMN1 and SMN2 genes for the diagnosis and screening of SMA

  • High resolution of SMN1/2 copy number across a broad range improves accuracy in identifying SMA patients and carriers
  • Excellent concordance of copy number and variant results compared to multiple orthogonal test methods

Download Brochure

*For Research Use Only. Not for use in Diagnostic procedures.

Analytical Performance

  • Automated and streamlined reporting of SMN1 and SMN2 copy number and variant detection via AmplideX Reporter Software (Figure 1)
  • Provide critical test results from a single reaction — and all in less than four hours (Figure 2)
  • Excellent concordance of SMN1 and SMN2 copy number results to sites’ in-house methods for over 400 replicates (Figure 3)
  • High assay specificity permits detection of SMN1–SMN2 hybrid peaks, including those resulting from gene conversion events (Figure 4)
  • 100% agreement observed between Sanger sequencing and AmplideX SMA Plus Kit for detection of SMN1 gene duplication and SMN2 disease modifier variants (Figure 5).

Figure 1.  Example Electropherogram Output for the AmplideX SMA Plus Kit

Figure 2.  AmplideX SMA Plus Kit Testing Workflow

Figure 3.  Excellent reproducibility of SMN1 and SMN2 copy number reporting across sites for over 400 replicates

Figure 4.  Detection and identification of SMN1 and SMN2 “hybrid peaks”

Figure 5. Agreement between AmplideX SMA Plus Kit and Sanger sequencing for SMN1 gene duplication (“silent carrier”) and SMN2 disease modifier variants

Additional Resources

Videos

Analytical validation of a multiplex PCR/CE assay for simultaneous determination of SMN1/SMN2 exon 7 copy number and variant status (Milligan J, et al).  Presented at ESHG 2020.2 Virtual Conference.

Looking Beyond Copy Number, Part 2:  Rapid, Comprehensive, and Complete SMN1/2 Profiling with the AmplideX® SMA Plus Kit + Q&A (Lemmink H, et al).  Presented at ESHG 2020.2 Virtual Conference.

Ordering Information

Product NameNumber of ReactionsCatalog Number
AmplideX® SMA Plus Kit50A00055
AmplideX® SMA Plus Kit100A00056

T 1-877-777-1874; 512-681-5200 F 512-681-5202 E orders@asuragen.com

View Sales Contacts
蚂蚁淘电商平台
ebiomall.com
公司介绍
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
常见问题
蚂蚁淘所售产品均为正品吗?
蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
下单后可以修改订单吗?
未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
商品几天可以发货?
现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
订单如何取消?
如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
可以开发票吗?
本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
如何联系商家?
蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
收到的商品少了/发错了怎么办?
同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
退换货/维修需要多长时间?
一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
商品咨询