Instructions-2010 NANOGOLD® non-functional, Rev. 1.3 (3/00)
Nanoprobes HomeCelebrating 25 years of innovation!
Tel: 631-205-9490Fax: 631-205-9493US toll free: 877-447-6266
ProductsInstructionsTech HelpApplicationsReferencesJobsNanoprobes NewsAbout UsContact Us
View Cart 647 FluoroNanogold™ for Super-Res!Join our Mailing List

[Nanoprobes Tech Support (14k)]Updated: March 24, 2000

NANOGOLD® PRODUCT INFORMATION

Nanogold®, Gold Particles, Non-Functional (NG)[Nanogold®, Gold Particles, Non-Functional (NG) product page]Buy onlineProduct Name: NANOGOLD® (NG)Catalog Numbers:    2010Appearance:Brown solidRevision:1.3 (March 2000)

Technical Assistance Online[2010-PDF]  Instructions (PDF)[2010-PDF]  Material Safety Data Sheet (PDF)

General InformationNANOGOLD® (NG) is a revolutionary new type of gold particle, prepared using a process that gives precise control over its size distribution and surface properties. NANOGOLD® particles are a uniform 1.4 nm in diameter, making them a suitable calibration standard for electron microscopy. They do not aggregate, as do colloidal gold products, nor do they possess affinity for proteins as colloidal gold particles do.1 This product does not posess active functionality: it cannot be linked specifically to proteins or antibodies. It is anticipated that this product will be used as a size or resolution standard for the electron microscope.

NANOGOLD® particles should be frozen upon receipt, and stored at -20°C.

Warning:For research use only. Not recommended or intended for diagnosis of disease in humans or animals.Do not use internally or externally in humans or animals.Non radioactive and non carcinogenic.Product SpecificationsNANOGOLD® is supplied as a solid, lyophilized from methanol solution. It is purified by gel filtration, and is stable under a wide range of pH conditions. It is soluble in alcohols, acetone, dichlorometane and similar solvents; it is also soluble in aqueous buffer systems such as phosphate buffered saline (150 mM NaCl).Extinction coefficients at specific wavelengths are given below for a methanol solution:

WAVELENGTH (nm)EXTINCTION COEFFICIENT*2802.25 X 1054201.12 X 105*Measured for 5 X 10-6 M solution in methanol. Using Stains with Nanogold®Because the 1.4 nm NANOGOLD® particles are so small, over staining with OsO4, uranyl acetate or lead citrate may tend to obscure direct visualization of individual NANOGOLD® particles.Three recommendations for improved visibility of NANOGOLD® are:

  1. Use of reduced amounts or concentrations of usual stains.
  2. Use of lower atomic number stains such as NANOVAN, a Vanadium based stain.2
  3. Enhancement of NANOGOLD® with silver developers, such as LI SILVER or HQ SILVER.
ContentsTemperature CautionAlthough NANOGOLD® is usually stable,3 under some conditions labeled specimens or conjugates may not be stable above 50°C. Best results are obtained at room temperature or 4°C.Avoid 37°C incubations.Use low temperature embedding media (e.g., Lowicryl) if labeling before embedding;4 do not bake tissue blocks with NANOGOLD®. If your experiment requires higher temperature embedding, then silver enhancement should be performed before embedding.Thiol CautionCAUTION: NANOGOLD® particles degrade upon exposure to concentrated thiols such as beta-mercaptoethanol or dithiothreitol. If such reagents must be used, concentrations should be kept below 1 mM and exposure restricted to 10 minutes or less. Instructions for UseThe product is supplied as 10 nmol of solid. If you require less than this, then dissolve the sample in 1.0 mL methanol and pipette the required amount into a polyethylene tube. The methanol may then be blown off using nitrogen; the dark brown residue may be dissolved in the required solvent. A methanol solution of NANOGOLD® particles is stable for several months at 2 - 8°C. Special Considerations for Direct Viewing of Nanogold® in the Electron MicroscopeFor most work, silver enhancement is recommended to give a good signal in the electron microscope (see below). For particular applications, visualization of the NANOGOLD® directly may be desirable. Generally this requires very thin samples and precludes the use of other stains.

NANOGOLD® provides a much improved resolution and smaller probe size over colloidal gold conjugates. However, because NANOGOLD® is only 1.4 nm in diameter, it will not only be smaller, but will appear less intense than, for example, a 5 nm gold particle.With careful work, however, NANOGOLD® may be seen directly through the binoculars of a standard EM even in 80 nm thin sections.However, achieving the high resolution necessary for this work may require new demands on your equipment and technique.Several suggestions follow:

  1. Before you start a project withNANOGOLD® it is helpful to see it so you know what to look for.Dilute the NANOGOLD® stock 1:5 and apply 4 ml to a grid for 1 minute.Wick the drop and wash with deionized water 4 times.

  2. View NANOGOLD® at 100,000 X magnification with 10 X binoculars for a final magnification of 1,000,000 X.Turn the emission up full and adjust the condenser for maximum illumination.

  3. The alignment of the microscope should be in order to give 0.3 nm resolution.Although the scope should be well aligned, you may be able to skip this step if you do step

  4. Objective stigmators must be optimally set at 100,000 X.Even if the rest of the microscope optics are not perfectly aligned, adjustment of the objective stigmators may compensate and give the required resolution.You may want to follow your local protocol for this alignment but since it is important, a brief protocol is given here:

    1. At 100,000 X (1 X 106 with binoculars), over focus, under focus, then set the objective lens to in focus.This is where there is the least amount of detail seen.
    2. Adjust each objective stigmator to give the least amount of detail in the image.
    3. Repeat steps a and b until the in focus image contains virtually no contrast, no wormy details, and gives a flat featureless image.

  5. Now underfocus slightly, move to a fresh area, and you should see small black dots of 1.4 nm size.This is the NANOGOLD®.For the 1:5 dilution suggested, there should be about 5 to 10 gold spots on the small viewing screen used with the binoculars. Contrast and visibility of the gold clusters is best at 0.2 - 0.5 m defocus, and is much worse at typical defocus values of 1.5 - 2.0 m commonly used for protein molecular imaging.

  6. In order to operate at high magnification with high beam current, thin carbon film over fenestrated holey film is recommended. Alternatively, thin carbon or0.2% Formvar over a 1000 mesh grid is acceptable.Many plastic supports are unstable under these conditions of high magnification/high beam current and carbon is therefore preferred.Contrast is best using thinner films and thinner sections.

  7. Once you have seen NANOGOLD® you may now be able to reduce the beam current and obtain better images on film. For direct viewing with the binoculars reduction in magnification from 1,000,000 X to 50,000 X makes the NANOGOLD® much more difficult to observe and not all of the golds are discernable.At 30,000 X (300,000 X with 10 X binoculars) NANOGOLD® particles are not visible.It is recommended to view at 1,000,000 X, with maximum beam current, align the objective stigmators, and then move to a fresh area, reduce the beam, and record on film.

  8. If the demands of high resolution are too taxing or your sample has an interfering stain, a very good result may be obtained using silver enhancement to give particles easily seen at lower magnification.
Silver Enhancement of Nanogold® ParticlesNANOGOLD® will nucleate silver deposition resulting in a dense particle 2-20 nm in size or larger depending on development time. Our LI SILVER silver enhancement system is convenient and not light sensitive, and suitable for all applications. Improved results in the EM may be obtained using HQ SILVER, which is formulated to give more controllable particle growth and uniform particle size distribution.5

Specimens must be thoroughly rinsed with deionized water before silver enhancement reagents are applied. This is because the buffers used for antibody incubations and washes contain chloride ions and other anions which form insoluble precipitates with silver. These are often light-sensitive and will give non-specific staining. To prepare the developer, mix equal amounts of the enhancer and initiator immediately before use. NANOGOLD® will nucleate silver deposition resulting in a dense particle 2-20 nm in size or larger depending on development time. Use nickel grids (not copper).

Silver enhancement is performed as follows:

  1. Rinse with deionized water (2 X 5 mins).
  2. OPTIONAL (may reduce background): Rinse with 0.02 M sodium citrate buffer, pH 7.0 (3 X 5 mins).
  3. Float grid with specimen on freshly mixed developer for 1-4 minutes (HQ SILVER), or as directed in the instructions for the silver reagent.More or less time can be used to control particle size. A series of different development times should be tried, to find the optimum time for your experiment.
  4. Rinse with deionized water (3 X 1 min).
Fixing with osmium tetroxide may cause some loss of silver; if this is found to be a problem, slightly longer development times may be appropriate.

NOTE: Treatment with osmium tetroxide followed by uranyl acetate staining can lead to much more drastic loss of the silver enhanced NANOGOLD®particles. This may be prevented by gold toning:6

  1. After silver enhancement, wash thoroughly with dionized water.
  2. 0.05 % gold chloride: 10 minutes at 4°C.
  3. Wash with deionized water.
  4. 0.5 % oxalic acid: 2 mins at room temperature.
  5. 1 % sodium thiosulfate (freshly made) for 1 hour.
  6. Wash thoroughly with deionized water and embed according to usual procedure.

Light Microscopy with Nanogold®Features labeled with NANOGOLD® will be stained black in the light microscope upon silver enhancement. Different development times should be tried to determine which is best for your experiment. A suitable procedure is given below.

Samples must be rinsed with deionized water before silver enhancement. This is because the reagent contains silver ions in solution, which react to form a precipitate with chloride, phosphate and other anions which are components of buffer solutions. The procedure for immunolabeling with NANOGOLD® and silver enhancement is given below.

  1. Incubate with NANOGOLD® reagent diluted 1/40 - 1/200 in PBS-BSA or another buffer suitable for the system under study, for 1 hour at room temperature.
  2. Rinse with PBS (3 X 5 min).
  3. Postfix with 1 % glutaraldehyde in PBS at room temperature (3 mins).
  4. Rinse with deionized water (3 X 1 min).
  5. OPTIONAL (may reduce background): Rinse with 0.02 M sodium citrate buffer, pH 7.0 (3 X 5 mins).
  6. Develop specimen with freshly mixed developer for 5-20 minutes, or as directed in the instructions for the silver reagent. More or less time can be used to control intensity of signal. A series of different development times may be used, to find the optimum enhancement for your experiment; generally a shorter antibody incubation time will require a longer silver development time.
  7. Rinse with deionized water (2 X 5 mins).
  8. The specimen may now be stained if desired before examination, with usual reagents.

PBS-BSA Buffer:

20 mM phosphate150 mM NaClpH 7.400.5% BSA0.1% gelatin (high purity)

Optional, may reduce background:0.5 M NaCl0.05% Tween 20PBS Buffer:

20 mM phosphate150 mM NaClpH 7.40

To obtain an especially dark silver signal, the silver enhancement may be repeated with a freshly mixed portion of developer.

References

  1. Hainfeld, J. F, and Furuya, F. R., J. Histochem. Cytochem., 40, 177 (1992); Furuya, F. R., Hainfeld, J. F., and Powell, R. D., Proc. 49th Ann. Mtg., Micros. Soc. Amer.; Bailey, G. W., and Hall, E. L. (Eds.); San Francisco Press, San Francisco, CA,1991, p.286.

  2. Tracz, E., Dickson, D. W., Hainfeld, J. F., and Ksiezak-Reding, H. Brain Res., 773, 33-44 (1997); Gregori, L., Hainfeld, J. F., Simon, M. N., and Goldgaber, D. Binding of amyloid beta protein to the 20S proteasome. J. Biol. Chem., 272, 58-62 (1997); Hainfeld, J. F.; Safer, D.; Wall, J. S.; Simon, M. N.; Lin, B. J., and Powell, R. D.; Proc. 52nd Ann. Mtg., Micros. Soc. Amer.; G. W. Bailey and Garratt-Reed, A. J., (Eds.); San Francisco Press, San Francisco, CA, 1994, p. 132.

  3. Hainfeld, J. F., and Furuya, F. R.; in Immunogold-Silver Staining: Principles, Methods and Applications (M. A. Hayat, Ed.), CRC Press, Boca raton, FL., 1995: pp. 71-96.

  4. Krenács, T., and Krenács, L.; in Immunogold-Silver Staining: Principles, Methods and Applications (M. A. Hayat, Ed.), CRC Press, Boca raton, FL., 1995: pp. 57-69.

  5. Humbel, B. M.; Sibon, O. C. M.; Stierhof, Y.-D., and Schwarz, H.: Ultra-small gold particles and silver enhancement as a detection system in immunolabeling and In Situ hybridization experiments; J. Histochem. Cytochem., 43, 735-737 (1995).

  6. Arai, R., et al.; Brain Res. Bull.28, 343-345 (1992).
Technical Assistance Available.

For a complete list of references citing this product, please visit our References page.

View Cart
Tel: 631-205-9490Fax: 631-205-9493US toll free: 877-447-6266
Nanoprobes.com
© 1990-2018 Nanoprobes, Inc. All rights reserved. Sitemap
蚂蚁淘电商平台
ebiomall.com
公司介绍
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
常见问题
蚂蚁淘所售产品均为正品吗?
蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
下单后可以修改订单吗?
未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
商品几天可以发货?
现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
订单如何取消?
如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
可以开发票吗?
本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
如何联系商家?
蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
收到的商品少了/发错了怎么办?
同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
退换货/维修需要多长时间?
一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
商品咨询