请使用支持JavaScript的浏览器! +,Active Rac1 ELISA, G-LISA, Rac activation, assay, kit, Active Rac蚂蚁淘商城
商品信息
联系客服
Cytoskeleton/Rac1 G-LISA Activation Assay (Luminescence format) - 96 assays/96 assays/BK126
郑重提醒:
无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
Cytoskeleton/Rac1 G-LISA Activation Assay (Luminescence format) - 96 assays/96 assays/BK126
品牌 / 
Cytoskeleton
货号 / 
BK126
美元价:
(友情提示:该价格仅为参考,欢迎联系客服询价!)
数    量:
免费咨询热线
4000-520-616
Details

Product Uses Include

  • Rac1 signaling pathway studies
  • Rac1 activation assays with primary cells
  • Studies of Rac1 activators and inactivators
  • Rac1 activation assays with limited material
  • High throughput screens for Rac1 activation/inhibition

IntroductionThe G-LISA series of Small G-Protein Activation Assays are ELISA based assays with which you can measure the GTP form of small G-proteins from lysates of cells or tissues and all in less than 3 h. The level of activation is measured with luminescence. For a more detailed introduction on G-LISA™ assays and a listing of other available G-LISA™ kits, see our main G-LISA™ page. The Rac1 G-LISA™ Activation Assay (Cat.# BK126) measures the level of GTP-loaded Rac1 protein in cell lysates, this is in contrast to Cat. BK125 which does not distinguish between activated Rac1,2 or 3. For a kit to measure RhoA activation please check webpage BK124.

The Rac1 G-LISA Activation Assay is very sensitive and has excellent accuracy for duplicate samples. See G-LISA™ FAQs tab on our G-LISA™ page for more details.

Kit contentsThe kit contains sufficient reagents to perform 96 Rac activation assays. Since the Rac-GTP affinity wells are supplied as strips and the strips can be broken into smaller pieces, each kit can be used for anywhere from one to multiple assays. The following components are included in the kit:

  1. 96 Rac-GTP affinity wells (divisible into 96 individual wells)
  2. Lysis buffer
  3. Binding buffer
  4. Antigen presenting buffer
  5. Wash buffer
  6. Antibody dilution buffer
  7. Anti-Rac1 antibody
  8. HRP-labeled secondary antibody
  9. Positive control Rac1 protein
  10. Protease inhibitor cocktail (Cat. # PIC02)
  11. Luminescence detection reagents
  12. Precision Red™ Advanced protein assay reagent (Cat. # ADV02)
  13. Manual with detailed protocols and extensive troubleshooting guide

Equipment needed

  1. 96-well plate luminometer
  2. Multichannel or multidispensing pipettor
  3. Orbital microplate shaker capable of at least 200 rpm shaking (400 rpm is optimal)

Example resultsSerum starved Swiss 3T3 cells were stimulated with the Rac activating compound EGF and Rac activation was measured with the G-LISA method (Fig 1 and 2).

BK126_S-N

Figure 1. Rac1 activation by EGF measured by G-LISA™ kit BK126. Swiss 3T3 (mouse) cells were serum starved for 24 h and treated with EGF (10ng/ml for 2.5 min) or buffer only (SS). 10 µg of cell lysates were subjected to the G-LISA™ assay. Luminescence measured over 100 milli-second.

BK126_cv

Figure 2. Rac  activation by EGF measured by G-LISA™.  Swiss 3T3 cells were serum starved (SS) for 24 h and treated with EGF (10 ng/ml for 2 min). 60, 30, 15, 7.5, 2.5 µg of cell lysates were subjected to the G-LISA™ assay. Luminescence was measured over 10 milli-seconds. 500 µg of the same lysates were subjected to the traditional PAK pull-down assay (shown in inset, Cat.# BK035).

Go to main G-LISA™ page

G-LISA Products:Cdc42 G-LISA™ Activation Assay, colorimetric format (Cat.# BK127)Rac1,2,3 G-LISA™ Activation Assay, colorimetric format (Cat.# BK125)RhoA G-LISA™ Activation Assay, colorimetric format (Cat.# BK124)RhoA G-LISA™ Activation Assay, luminescence format (Cat.# BK121)

Associated Products:Anti-Cdc42 monoclonal antibody (Cat.# ACD03)Anti-Rac1 monoclonal antibody (Cat.# ARC03)Anti-RhoA monoclonal antibody (Cat.# ARH03)

About

For product Datasheets and MSDSs please click on the PDF links below.   For additional information, click on the FAQs tab above or contact our Technical Support department at tservice@cytoskeleton.com

  •  G-LISA Activation Assay Technical Guide download here
  • For our G-LISA Data Analysis (Luminescence) Excel Template please download here.

 

    Citations

    Binker et al., 2011. TGF-β1 increases invasiveness of SW1990 cells through Rac1/ROS/NF-κB/IL-6/MMP-2. Biochem. Biophys. Res. Comm. v 405, pp 140-145.

    Sayedyahossein et al., 2012. Essential role of integrin-linked kinase in regulation of phagocytosis in keratinocytes. FASEB J. doi: 10.1096/fj.12-207852.

    Kikuchi et al., 2012. Protein kinase C iota as a therapeutic target in alveolar rhabdomyosarcoma. Oncogene. doi:10.1038/onc.2012.46.

    Eggers et al., 2012. STE20-related Kinase Adaptor Protein α (STRADα) Regulates Cell Polarity and Invasion through PAK1 Signaling in LKB1-null Cells. J. Biol. Chem. v 287, pp 18758-18768.

    Vives et al. (2011). The Rac1 exchange factor Dock5 is essential for bone resorption by osteoclasts. Journal of Bone and Mineral Research 26 ,1099.

    McHenry et al. (2010). P190B RhoGAP has pro-tumorigenic functions during MMTV-Neu mammary tumorigenesis and metastasis. Breast Cancer Res.

    Johanna et al. (2010). Rac1 activity changes are associated with neuronal pathology and spatial memory long-term recovery after global cerebral ischemia. Neurochem International 57 ,762-773.

    Baumer et al., 2009. J Cell Physiol. 220, 716

    Heckman-Stoddard et al. (2009). Haploinsufficiency for p190B RhoGAP inhibits MMTV-Neu tumor progression. Breast Cancer Research 11 ,http://breast-cancer-research.com/content/11/4/R61.

    Chastre et al. (2009). TRIP6, a novel molecular partner of the MAGI-1 scaffolding molecule, promotes invasiveness. FASEB Journal 23 ,916–928.

    Ramirez et al., 2008. J Immunol. 180, 1854

    Moniz et al. (2008). WNK2 modulates MEK1 activity through the Rho GTPase pathway. Cellular Signalling 20 ,1762-68.

    Pontow et al., 2007. Virology. 368, 1

    Faqs

    Question 1: There is less than a 2-fold difference in signal intensity between my positive control and lysis buffer blank. Why?

    Answer 1: To accurately measure luminescence signal intensity between the positive control and buffer blank, please check the instrument settings on the luminometer (see below for suggestions). We also recommend running some “set-up” experiments with just the buffer blank and positive control to determine optimal settings for detecting the positive control signal 3-5 fold higher than the buffer blank. It is also important to remember to use a fresh control protein tube for each run of positive control samples. Do not store and re-use the positive control.

    Machine Settings

    Gain

    Gain controls the sensitivity of the machine. Most luminometers do not allow manual alteration of gain and use an auto-calibration or limited calibration function. Turn off auto-settings and auto-calibration to use the machine in manual mode. It is important to contact the luminometer manufacturer or consult the user’s manual to determine the best way to alter the machine sensitivity. If gain can be altered, one should read at low, medium and high gains to determine the reading within the linear range of the assay (positive control should be 3-5X higher than blank). Gain range varies with instrument. For example, gain in the Tecan GmbH SpectroFluor Plus ranges from 0 - 150 (where 150 is the highest).

    Integration Time

    This parameter can be varied on most machines. It is a good idea to set the machine at the lowest integration time (usually 10 – 100 ms). Integration times greater than 200 ms are likely to read out of the linear range of the assay and may require lowering of gain or dilution of primary and/or secondary antibodies.

    Shaking

    Most machines give the shaking option. The recommended setting is 5 sec shake, medium orbital speed before read. This option is not essential to the assay.

    Temperature

    Room temperature

    Plate type

    Any setting that specifies 96 well flat, white will be sufficient.

    Filters

    Luminescence does not require excitation or emission filters so the filter spaces should be left blank. If this is not an option, excitation can be set at any value and emission should be set between 400-500nm, with 430-445 as optimal setting.

    Question 2: My arbitrary luminescence units (ALU) or relative luminescence units (RLU) are very different from what is depicted in the manual. Why?

    Answer 2: This is very typical as the luminescence units will vary from luminometer to luminometer based on the machine’s sensitivity and instrument settings. The important information to take note of is what the relationship is between buffer blank and positive control luminescence values. The positive control signal should be 3-5 fold greater than the buffer blank luminescence signal. If that is the case, then the G-LISA assay is functioning in the linear range and experimental samples can now be processed.

    If you have any questions concerning this product, please contact our Technical Service department at tservice@cytoskeleton.com.

    蚂蚁淘电商平台
    ebiomall.com
    公司介绍
    公司简介
    蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
    蚂蚁淘承诺
    正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
    及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
    轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
    售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
    常见问题
    蚂蚁淘所售产品均为正品吗?
    蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
    下单后可以修改订单吗?
    未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
    商品几天可以发货?
    现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
    订单如何取消?
    如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
    可以开发票吗?
    本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
    如何联系商家?
    蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
    收到的商品少了/发错了怎么办?
    同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
    退换货/维修需要多长时间?
    一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
    商品咨询