Deprecated: Required parameter $cat_id follows optional parameter $type in /data/ebiomall/systems/hong.php on line 2088

Deprecated: Required parameter $where follows optional parameter $tree_id in /data/ebiomall/systems/hlb.php on line 3505
MCLAB/2X HotSybr qPCR Kit/HSM400/1 Ea-蚂蚁淘商城
新闻动态

MCLAB/2X HotSybr qPCR Kit/HSM400/1 Ea

  
  2026-07-31
  
Sybr green dye based 4x1.25ml for 200 reactions. Designed for all kinds of real-time PCR machines.
Rox Reference DyeInstrumentCatalog No.
No RoxBioRad iCycler MiniOpticon, Opticon 2, Chromo 4, iQ5; Roche LightCycler 480; MJ Research DNA Engine Opticon 2, Chromo 4; Corbett Rotogene 3000, 6000HSM400RF
Low RoxABI® 7500 qPCR Systems, ViiA™ 7, QuantStudio™ 12K Flex, Agilent Mx3000P™ Mx3005P™ and Mx4000™HSM400LR
Regular RoxABI® PRISM® 7000, 7700, 7900HT, ABI® 7300 qPCR Systems, GeneAmp® 5700, StepOne™, and the StepOnePlus™HSM400

For Research Use Only.

\"2hosybrpcrkits.jpg\"Figure: Amplification of human GAPDH gene target with 2X HotSybr Real-time PCR Kit. Amplification curves are shown for ten fold dilutions of 0.0002pM to 20pM of plasmid. Insets show the dissociation profile and the standard curve data.

Description:This is a high performance real-time PCR reagent. It utilizes MCLAB's proprietary quantitative PCR technology.Advantages:2x HotSybr PCR Reaction Mix products cut the total reaction time down to half.\"mclab_pcr_image002.gif\"- Normally the total reaction time is 4350 seconds: 95°C, 10 minutes => (95°C, 15 seconds => 60°C, 60 seconds) x 50- For MCLAB's 2x HotSybr PCR Reaction Mix, the total reaction time is reduced to 2350 seconds: 95°C, 10 minutes => (95°C, 5 seconds => 60°C, 30 seconds) x 50Application:Sybr green dye based quantitative PCR: including DNA quantification, 2-step RT PCR, SNP analysis, etc.Primer and probe design: Appropriate software, such as ABI Primer ExpressTM, should be used.Recommended Reaction Conditions:95°C, 10 minutes -> (95°C, 5 seconds. -> 60°C, 30 seconds.) for 50 cycles -> melting curve.Recommended Storage Conditions: -20°CNotes:To achieve accurate quantification, it is highly recommended to (1) do replicates; (2) reduce pipetting error; (3) primer concentration from 100nM to 300nM; (4) run melting curve following amplification cycles.Reference: Higuchi R, Dollinger G, Walsh PS, Griffith R; Bio/Technology 10: 413-417, 1992

本文链接: https://www.ebiomall.cn/b377-mclab/info-1558689430.html

免责声明 本文仅代表作者个人观点,与本网无关。其创作性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不做任何保证或承诺,请读者仅作参考,并请自行核实相关内容。
版权声明 未经蚂蚁淘授权不得转载、摘编或利用其他方式使用上述作品。已经经本网授权使用作品的,应该授权范围内使用,并注明“来源:蚂蚁淘”。违反上述声明者,本网将追究其相关法律责任。
没有了