Fluorescein Tyramide | Biotium
Bioscience kitsThe guaranteed shelf life from date of receipt for bioscience kits is listed on the product information sheet. Some kits have an expiration date printed on the kit box label, this is the guaranteed shelf life date calculated from the day that the product shipped from our facility. Kits often are functional for significantly longer than the guaranteed shelf life. If you have an older kit in storage that you wish to use, we recommend performing a small scale positive control experiment to confirm that the kit still works for your application before processing a large number of samples or precious samples.
Antibodies and other conjugatesThe guaranteed shelf life from date of receipt for antibodies and conjugates is listed on the product information sheet. Antibodies and other conjugates often are functional for significantly longer than the guaranteed shelf life. If you have an older conjugate in storage that you wish to use, we recommend performing a small scale positive control experiment to confirm that the product still works for your application before processing a large number of samples or precious samples.
For lyophilized antibodies, we recommend reconstituting the antibody with glycerol and antimicrobial preservative like sodium azide for the longest shelf life (note that sodium azide is not compatible with HRP-conjugates).
Chemicals, dyes, and gel stainsBiotium guarantees the stability of chemicals, dyes, and gel stains for at least a year from the date you receive the product. However, the majority of these products are highly stable for many years, as long as they are stored as recommended. Storage conditions can be found on the product information sheet or product safety and data sheet, material safety data sheet, and on the product label. Fluorescent compounds should be protected from light for long term storage.
If you have a Biotium compound that has been in storage for longer than one year that you wish to use, we recommend performing a small scale positive control experiment to confirm that the compound still works for your application before processing a large number of samples or precious samples.
Expiration date based on date of manufacture (DOM)If your institution requires you to document expiration date based on date of manufacture for reagents, please contact techsupport@biotium.com for assistance.
Chemical products with special stability considerations:
Esters
Ester compounds include the following:• Succinimidyl esters (SE, also known as NHS esters), such as our amine-reactive dyes• Acetoxymethyl esters (AM esters) such as our membrane-permeable ion indicator dyes• Diacetate-modified dyes, like ViaFluor™ 405, CFDA, and CFDA-SE cell viability/cell proliferation dyes
Ester dyes are stable in solid form as long as they are protected from light and moisture. Esters are not stable in aqueous solution. Concentrated stock solutions should be prepared in anhydrous DMSO (see Biotium catalog no. 90082). Stock solutions in anhydrous DMSO can be stored desiccated at -20°C for one month or longer. Esters should be diluted in aqueous solution immediately before use. Succinimidyl esters (SE) should be dissolved in a solution that is free of amine-containing compounds like Tris, glycine, or protein, which will react with the SE functional group. AM esters and diacetate compounds should be dissolved in a solution that is free of serum, because serum could contain esterases that would hydrolyze the compound.
A note on CF™ dye succinimidyl ester stabilitySuccinimidyl esters are generally susceptible to hydrolysis, which can result in lower labeling efficiency. Heavily sulfonated dyes, such as the Alexa Fluor® dyes, DyLight® dyes and IRDyes® are particularly hygroscopic, worsening the hydrolysis problem. For example, the percent of active Alexa Fluor® 488 succinimidyl ester (SE) could be well below 50% by the time of application (according to the manufacturer’s product datasheet). In a number of Alexa Fluor® SE reactive dyes, the SE group is derived from an aromatic carboxylic acid, while in all of Biotium’s CF™ dyes the SE group is prepared from an aliphatic carboxylic acid. This structural difference reduces the susceptibility of CF™ dye SE reactive groups to hydrolysis, resulting in relatively stable reactive dyes with consistently higher labeling efficiency compared to other SE derivatives of other fluorescent dyes.
Maleimides, MTS and thiosulfate dyesLike the succinimidyl ester dyes, these dyes are also susceptible to hydrolysis, although generally to a much lower degree. Thus, for long term storage, anhydrous DMSO is recommended for making stock solutions.
Other reactive dyesAmines, aminooxy (also known as oxylamine), hydrazide, azide, alkyne, BCN, and tyramide reactive dyes, as well as dye free acids, are generally stable in aqueous solution when stored at -20°C for 6-12 months or longer, as long as no compounds are present that may react with the dye’s functional group. See the product information sheets for specific reactive dyes more information.
Coelenterazines and D-luciferin
Coelenterazines are stable in solid form when stored as recommended; they are not stable in aqueous solution. Concentrated coelenterazine stock solutions (typically 1-100 mg/mL) should be prepared in ethanol or methanol; do not use DMSO or DMF to dissolve coelenterazines, because these solvents will oxidize the compounds. Ethanol or methanol stocks of coelenterazine can be stored at -20°C or below for six months or longer; alcohol stocks may evaporate during storage, so use tightly sealing screw cap vials and wrap the vials with Parafilm for long term storage. Propylene glycol also can be used as a solvent to minimize evaporation. If the solvent evaporates, the coelenterazine will still be present in the vial, so note the volume in the vial prior to storage so that you can adjust the solvent volume to correct for evaporation if needed. Prepare working solutions in aqueous buffers immediately before use. Coelenterazines are stable for up to five hours in aqueous solution.
Aquaphile™ coelenterazines are water soluble formulations of coelenterazines. They are stable in solid form when stored as recommended. Aquaphile™ coelenterazines should be dissolved in aqueous solution immediately before use. They are stable for up to five hours in aqueous solution.
Note that coelenterazines are predominantly yellow solids, but may contain dark red or brown flecks. This does not affect product stability or performance. If your coelenterazine is uniformly brown, then it is oxidized and needs to be replaced.
D-luciferin is stable in solid form and as a concentrated stock solution when stored as recommended; it is not stable at dilute working concentrations in aqueous solution. Prepare concentrated D-luciferin stock solutions (typically 1-100 mg/mL) in water, and store in aliquots at -20°C or below for six months or longer. Prepare working solutions immediately before use.
Category: CF® Dyes, Mix-n-Stain™ Antibody Labeling Kits, NucView® Caspase-3 Enzyme Substrates, DNA Quantitation Kits, Luciferase Assays, Product shipping, storage, shelf life, solubilityView more FAQs The product label says protect from light, why isn t it in an amber vial?Some of our large volume light-sensitive products are packaged in amber bottles or amber glass vials, which are easy to handle and protect the products from light. However, amber micro packaging vials (0.5 mL or 2 mL) make it very difficult to see small quantities of dye when preparing solutions or pipetting. Therefore, we only package photoreactive dyes like PMA or PMAxx in amber micro packaging vials. Some of our reactive dyes are packaged in transparent vials, then sealed inside a moisture-resistant foil bag, which also will protect them from light.
Other fluorescent dyes in transparent vials should stored in the dark for long term storage. It s fine to store dye vials uncovered in a windowless refrigerator or freezer with an automatic light shut-off. If dyes will be stored in a glass-front (deli-style) refrigerator, walk-in refrigerator/freezer, or at room temperature with constant light exposure, they should stored in a non-transparent box (like a white cardboard freezer box), in a closed drawer, in a black plastic bag, or covered with aluminum foil.
Fluorescent dyes generally are not sensitive to brief light exposure while they are being handled on the bench during an experiment. To be on the safe side, we usually loosely cover tube racks with a piece of foil if the dye vials are going to be out on the bench for more than 30 minutes or so. But most dyes are stable enough that even accidentally leaving them on the bench for a day will not affect performance. When handling photoreactive dyes like EMA, PMA, or PMAxx, we take the extra precaution of dimming the lights.
Category: Product shipping, storage, shelf life, solubilityView more FAQsShipping, Handling & Tax (CA only) not included in price. Learn more Tax is assessed in the state of California. All fees will be calculated during checkout based on your shipping information and are subject to change.
This fluorescein tyramide conjugate can be used for tyramide signal amplification (TSA)1,2,3, which is an enzyme-mediated detection method that uses horseradish peroxidase (HRP) to generate high-density labeling of a target protein or nucleic acid in situ. A tyramide conjugate is incubated in the presence of HRP (often bound to a secondary antibody), which catalyzes the binding of the tyramide (and associated label) to adjacent tyrosines for enhanced fluorescent signal.
Also see our CF® Dye Tyramide Signal Amplification Kits.
Anhydrous DMSO (dimethyl sulfoxide; methyl sulfoxide) is recommended for preparing stock solutions of AM ester dyes, reactive dyes and other related moisture-sensitive products. Detailed View Kits for increasing immunofluorescence sensitivity using HRP-catalyzed tyramide signal amplification; with your choice of next-generation fluorescent CF® dyes or biotin. Detailed View Kits for increasing immunofluorescence sensitivity using HRP-catalyzed tyramide signal amplification; with your choice of next-generation fluorescent CF® dyes or biotin. Detailed View Kits for increasing immunofluorescence sensitivity using HRP-catalyzed tyramide signal amplification; with your choice of next-generation fluorescent CF® dyes or biotin. Detailed View Highly cross-adsorbed goat anti-mouse IgG (H+L) secondary antibody labeled with our superior CF® dyes. Detailed View Highly cross-adsorbed donkey anti-rabbit IgG (H+L) secondary antibody labeled with our superior CF® dyes. Detailed View Biotium implements a Quality System, certified by QAS according to Standard QAS ISO 9001:2015. Certificate No. US3564本文链接: https://www.ebiomall.cn/b78-biotium/info-1504813574.html