Properties:
Related Categories | 700 Series Microliter Syringe, 22° bevel, Agilent 7673/7683, Analytical/Chromatography, GC Autosampler Syringes, Hamilton Microliter Syringes for Agilent/HP 7673 & 7683, |
material | stainless steel needle bevel tip (point style 2) |
needle size | 23s ga (bevel tip) |
feature | needle type ASN (fixed) |
packaging | pkg of 1 ea |
mfr. no. | Hamilton, 80398 |
needle L | 43 mm (1.71 in.) |
volume | 10 μL |
Description:
General description
Hamilton′s Microliter™ syringe is to be used for liquid injection. This syringe is made of with a glass barrel with a hand-fitted stainless steel plunger. The plunger is individually fitted to its matching syringe barrel. The plunger is not to be used with any other syringe. Glass barrel with fitted stainless steel plunger. The needle has a special 22° bevel.
Note: Do not use these syringes with the Merlin Microseal septa.
Application
Hamilton® syringe is available in gas-tight type that minimizes the gas exchange in analysis. It gives accurate volume delivery. The plunger is mostly unsurpassed. Syringes can be replaceable or cemented.
Legal Information
Hamilton is a registered trademark of Hamilton Co.
Microliter is a trademark of Hamilton Co.
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
需要做脂肪代谢实验,打算通过在心肌新鲜组织匀浆中加入核素标记的脂肪酸代谢底物([14C]-Palmitate),通过液体闪烁计数仪测定氧化产物[14C]CO2的放射性计数来反应脂肪酸的氧化代谢率。但是实验室只有γ放射免疫计数仪,请问能否用其测量“软β射线”14C;仪器需要作何调整吗???
缺点是人工计数可能发生的随机误差较大。
1、同样的测量条件下,如测量相对几何位置相同,放射源相同,放射性测量计数率扣除本底后与活度在统计误差内成正比;
2、同样活度不同核素放射源,在其它条件相同的情况下放射性测量计数率不一定相同。因为不同核素衰变各能量分支比不同、粒子不同、能量不同,有的衰变子体也有放射性。
3、放射性测量计数率与计数器的探测效率相关。简单认为:活度=(计数率-本底计数率)/效率。其中效率的标定要与测量条件一致。
如何用IPP软件测量肌纤维的直径?求战友教教,带图的那种。另外如何给特定的细胞计数?
能不能用kappa检验,我看了论坛上的帖子,好像是不行的。但是看到一篇文章,计数资料却用了kappa检验,请问能否这样使用,如果能的话,应该用什么软件,怎么计算。谢谢
提到的文章见后
文章.rar(267.87k)
因为声的多普勒效应,用专用仪器在空气里测频率似乎变得不可靠。 最简单直接的方法,用频率特性仪,接换能器正负极测量读数 或者拿一片超声波振子接受对方发射的超声波进行放大后,输入到整形电路,再输入到计数器,就可以测量频率了