Deprecated: Required parameter $cat_id follows optional parameter $type in /data/ebiomall/systems/hong.php on line 2088

Deprecated: Required parameter $where follows optional parameter $tree_id in /data/ebiomall/systems/hlb.php on line 3505
+,QuantiChrom, BCP Albumin Assay Kit, DIAP-250, quantitative, colorimetric, absorbance, OD, albumin蚂蚁淘商城
商品信息
联系客服
BioAssay Systems/QuantiChrom™ BCP Albumin Assay Kit/250 tests/DIAP-250
郑重提醒:
无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
BioAssay Systems/QuantiChrom™ BCP Albumin Assay Kit/250 tests/DIAP-250
品牌 / 
BioAssay Systems
货号 / 
DIAP-250
美元价:
(友情提示:该价格仅为参考,欢迎联系客服询价!)
数    量:
免费咨询热线
4000-520-616

QuantiChrom™ BCP Albumin Assay Kit

QuantiChrom™ BCP Albumin Assay Kit Catalog No: DIAP-250
Price: $309 Qty:
For orders of 10 or more kits, please call +1-510-782-9988x1 oremail us for best pricing and/or bulk order. Shipping: RT Shipment: Fedex ServiceDelivery: 1-2 days (US), 3-6 days (Intl) Storage: 4, -20°C
Albumin Assay Kit (BCP)
  • Product Overview
  • Product FAQ
  • Product Citations
  • Assay Service
ProtocolSDS

Application

  • For quantitative determination of albumin.

Key Features

  • Sensitive and accurate. Use as little as 20 μL samples. Detection range 0.3 - 5 g/dL (45 - 750 μM) albumin in 96-well plate assay.
  • Simple and high-throughput. The procedure involves addition of a single working reagent and incubation for 5 min. Can be readily automated as a high-throughput assay for thousands of samples per day.
  • Improved reagent stability and versatility. The optimized formulation has greatly enhanced reagent and signal stability. Cuvet or 96-well plate assay.
  • Low interference in biological samples. No pretreatments are needed. Assays can be directly performed on raw biological samples i.e., in the presence of lipid and protein.

Method

  • OD610nm (BCP)

Samples

  • Serum, plasma, urine, biological preparations

Species

  • All

Size

  • 250 tests

Detection Limit

  • 0.3 g/dL

Shelf Life

  • 12 months

More Details

  • Albumin is the most abundant plasma protein in human. It accounts for about 60% of the total serum protein. Albumin plays important physiological roles, including maintenance of colloid osmotic pressure, binding of key substances such as long-chain fatty acids, bile acids, bilirubin, haematin, calcium, magnesium. It has anti-oxidant and anticoagulant effects, and also acts as a carrier for nutritional factors and drugs, as an effective plasma pH buffer. Serum albumin is a reliable prognostic indicator for morbidity and mortality, liver disease, nephritic syndrome, malnutrition and protein-losing enteropathies. High levels are associated with dehydration. Simple, direct and automation-ready procedures for measuring albumin concentration in biological samples are becoming popular in Research and Drug Discovery. BioAssay Systems BCP albumin assay kit is designed to measure albumin directly in biological samples without any pretreatment. The improved method utilizes bromcresol purple that forms a colored complex specifically with albumin. The intensity of the color, measured at 610nm, is directly proportional to the albumin concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw samples.

Your company sells two different kit (DIAG-250 and DIAP-250). What are the differences between them exactly? Is it just the wavelength of detection?

The two kits use different albumin specific dyes and hence the major difference lies in the sensitivity and wavelengths. Both assays have advantages and disadvantages. DIAG-250 (QuantiChrom BCG Albumin Assay Kit) uses bromcresol green, a dye that is more (about 2-fold) sensitive than bromcresol purple used in the BCP albumin assay. BCG is not absolutely specific for albumin, however, it also reacts with α1- and α2-globulins, and adds a positive bias. The BCP method, although more specific, underestimates albumin in certain samples, e.g. from patients undergoing hemodialysis. If your samples are sera or plasma, which have high albumin concentrations, I would suggest using the DIAP-250 assay kit (detection wavelength 610 nm). If the albumin concentration is low, DIAG-250 is the best choice (detection wavelength 620 nm).

Pooled plasma samples (EDTA) show high albumin concentrations with the bromcresol purple assay? What could be interfering with the assay?

There should be no significant differences between serum samples and plasma samples. Turbid plasma samples (fibrinogen) can cause high albumin readings. This can be adjusted for by blanking samples at OD 690 nm. BCP does not absorb at 690 nm, whereas the absorbance caused by turbididty is the same at 610 nm and 690 nm.

Since the concentration that I am measuring is very low, would it be reasonable to dilute the standard curve down to lower level so my sample is still within the curve?

Yes, as long as the standard curve is within the limits of the dynamic range, but this will not increase the sensitivity of the assay. To increase the sensitivity add a larger volume of sample and standard. For example, you could add 20 μL sample and 20 μL of diluted standards (instead of starting at 5 g/dL as shown in the standard protocol, start at 1 g/dL).For more detailed product information and questions, please feel free to Contact Us. Or for more general information regarding our assays, please refer to our General Questions.
Kelly E, et al (2011). Redistribution of labile plasma zinc during mild surgical stress in the rat. Transl Res. 157(3):139-49. Assay: Albumin in rat plasma. Olsen AS, et al (2010). Limb regeneration is impaired in an adult zebrafish model of diabetes mellitus. Wound Repair Regen. 18(5):532-42. Assay: Albumin in zebrafish blood. Sharifuzzaman SM and Austin B (2010). Kocuria SM1 controls vibriosis in rainbow trout (Oncorhynchus mykiss, Walbaum). J Appl Microbiol. 108(6): 2162 - 2170. Assay: Albumin in fish serum. Shin SY et al (2009). Immunological investigation in the adenoid tissues from children with chronic rhinosinusitis. Otolaryngol Head Neck Surg. 141(1):91-6. Assay: Albumin in human tissue. Shin SY, et al (2009). IgE response to staphylococcal enterotoxins in adenoid tissues from atopic children. Laryngoscope. 119(1):171-5. Assay: Albumin in human serum. Shin SY, et al (2009). Local production of total IgE and specific antibodies to the house dust mite in adenoid tissue. Pediatr Allergy Immunol. 20(2):134-41. Assay: Albumin in human blood. Yung S, et al (2009). Anti-DNA antibody induction of protein kinase C phosphorylation and fibronectin synthesis in human and murine lupus and the effect of mycophenolic acid. Arthritis Rheum. 60(7):2071-82. Assay: Albumin in human urine. Maier SM et al (2007) Proteinuria of Nonautoimmune Origin in Wild-type FVB/NJ Mice. Comp Med. 57(3) 255-266. Assay: Albumin in mouse urine and serum.To find more recent publications, pleaseclick here.
If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.Simply send us your samples:- Fast turnaround - Quality data - Low costPlease email or call 1-510-782-9988 x 2 to request assay service.
蚂蚁淘电商平台
ebiomall.com
公司介绍
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
TonkBio品牌试剂盒有哪些?全在这里了 查看更多>
美国ImmunoBioScience Corp(IBSC)公司介绍/品牌代理 查看更多>
Chemokine品牌细胞因子/免疫试剂价格/厂家直采/进口 查看更多>
ITSI-BIOSCIENCES(ITSIBIO)公司试剂盒抗体厂家直采/公司介绍 查看更多>
Preparation of Brain Cytosol1. Chill a glass plate on ice. 2. Place brain tissue on the chilled glass plate and cut slices of brain into small pieces. 3. Resus 查看更多>
在经典的Western Blot的世界里,蛋白电泳—转膜—封闭—抗体—显色这个五步骤环环相扣,构成WB完整过程,就象砌积木一样,少了前面一步的基础后面的就砌不上去。但是亲爱的朋友,告诉我,你们在一次又一次重复这个貌似简单又颇为费时的实验时,有没有设想过能省略掉其中的某个费时的非必需步骤 查看更多>
US Biomax品牌介绍产品分类/代理商试剂采购 查看更多>
牛血清蛋白(V)第五组分是个什么概念? 查看更多>
1。根据序列比对,相似性分析,初步估计蛋白质可能的功能2。查阅文献,看有否相关研究3。如果用血清,在未知功能情况下,很难有所作为,建议等初步知道功能后,用血清是验证抉具体作用的4。比较常用的未知基因分析方法,是从基因水平入手:将该基因敲除(现在可以考虑RNAi),看看在功能组、蛋白 查看更多>
血清前白蛋白是主要存在于血液中的运输蛋白,因电泳时位于白蛋白(Alb)之前而得名。PA的主要生理功能是结合、运输维生素A和甲状腺素,从而参与它们的调节。此外,PA还具有胸腺活性,可通过促进淋巴细胞成熟来增强机体免疫力,并在抗肿瘤方面有潜在的作用。人血清PA含量与人体的生理、病理状... 查看更多>
SPM-Biocameltec品牌介绍产品代理 查看更多>
制备高特异性、高效价的抗体是实验免疫学技术的基础,抗体质量的高低将直接影响试验的成败。 通过不同方法制备的抗体往往与多种杂蛋白混杂在一起,为了获得成分相对单一的抗体或将抗体用于特定的用途,就需要进行抗体纯化。从成分的角度分析, 抗体分子是一类蛋白质分子,与其他蛋白质一样... 查看更多>
常见问题
蚂蚁淘所售产品均为正品吗?
蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
下单后可以修改订单吗?
未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
商品几天可以发货?
现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
订单如何取消?
如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
可以开发票吗?
本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
如何联系商家?
蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
收到的商品少了/发错了怎么办?
同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
退换货/维修需要多长时间?
一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
商品咨询
我所分离的血清中含有较多的血红蛋白,我是通过辛酸-硫酸铵沉淀和high-Q离子层析,在通过辛酸-硫酸铵之后的沉淀还是红色的,不知道能不能过离子交换柱,会不会堵死,或者有什么方法把血红蛋白除去,请高手指教,谢谢大家了
用大肠杆菌表达纯化的蛋白,和人血清中这种蛋白的分子量不同,western显示血清中这种蛋白的分子量高于纯化的蛋白,请问各位这是为什么呢?如何解释呢?
脂蛋白分离纯化

一、分离脂蛋白

血浆是分离纯化脂蛋白的首选标本。从血浆(血清)中可分离得到CM、VLDL、LDL和HDL,再经脱脂除去脂蛋白中的脂质,剩下的部分为载脂蛋白的混合物。这一操作过程是获得载脂蛋白的最佳方法。

二、脱脂

由于各种脂蛋白含脂的种类和质量不同,脱脂剂组成略有差异。目前常用的几种脱脂方法有如下几种。

1.Warnick等法

将纯化的脂蛋白慢慢加入到预冷(-20℃)的丙酮:无水乙醇(1:1,V/V)混合液中,脱脂液的量为样品的20倍,不断搅拌,然后在-20℃冰箱放置过夜,4℃离心沉淀,将沉淀重复脱脂一次,用氮气吹干或真空干燥,脱脂物0℃贮存待用。

2.Scanu等法

将脂蛋白加入到预冷的(-15℃)无水乙醇:无水乙醚(3:2)混合液中,不断搅拌,以12h过夜,在-10℃或4℃离心(2000r/min),去上清留沉淀,再重复脱脂一次。用N2或真空干燥,0℃贮存待用。
蛋白质的分离纯化方法123
哲宇丶01962021-08-16
一.血清ǐ-球蛋白的初步提取
1. 血细胞与血清分离:
取人血液 1000ml,放置10min, 1000rpm离心20min .弃沉淀,留上清备用(沉淀为血细胞,上部为血清).
2. 乳糜粒分离:4000rpm 10°C离心10分钟,采用密度梯度离心
梯度液配置:离心管下部3/4容积加血浆,上部1/4容积加0.5MnaCl+0.3MEDTA,PH7.4 乳糜粒上浮,将乳糜粒吸出,留其余液体备用.
3. 血清蛋白分离:除去球蛋白,白蛋白及其它蛋白质.
都可以。SDS能测定蛋白质的分子量,这是鉴定的一个依据。在某些情况下,根据分子量就可以确定,但有时还需要其它信息。
芯片生化反应概述.pdf123
晚安8642021-07-31
一般认为血清白蛋白的正常值为40-55g/L,血清球蛋白为20-30g/L,血清总蛋白的正常值为60-80g/L,白球比的正常值为1.5-2.5。向左转|向右转
实验原理:
蛋白质在水溶液中的溶解度是由蛋白质周围亲水基团与水形成水化膜的程度,以及蛋白质分子带有电荷的情况决定的。当用中性盐加入蛋白质溶液,中性盐对水分子的亲和力大于蛋白质,于是蛋白质分子周围的水化膜层减弱乃至消失。同时,中性盐加入蛋白质溶液后,由于离子强度发生改变,蛋白质表面电荷大量被中和,更加导致蛋白溶解度降低,使蛋白质分子之间聚集而沉淀。一般33%硫酸铵为沉淀Ig-G的最适饱和度
缓冲液改成酸性的 而且要根据不同的pI进行
我想做关于血清铁蛋白的电泳,首先要分离和纯化铁蛋白。请各位老师和学长指点。
只要求定性它在蛋白中存在,已经知道kda,但是提纯比较困难。
各位朋友,我最近在做一植物病毒的外壳蛋白的表达;
蛋白已经表达出来了,接下来要去做抗血清
想要请公司做;
我看了论坛里很多帖子,做抗体的对蛋白的要求好像很低啊。
我想问我菌煮沸SDS-PAGE割胶回收的蛋白能不能用于抗血清的试验?(如果这样能用,可以省很多事情啊,不用去超声波,过柱子等纯化步骤)
量大概需要多少啊?

55KDa与24KDa目的条带处的目的条带为什么成“小草”一样,旁边没有mark的话就没有条带,有mark就出现“小草”样的条带,请各位大神答疑解难?感激不尽