商品信息
联系客服
郑重提醒:
无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
BioAssay Systems/QuantiChrom™ Phosphate Assay Kit/500 tests/DIPI-500
免费咨询热线
4000-520-616
QuantiChrom™ Phosphate Assay Kit
- Product Overview
- Product FAQ
- Product Citations
- Assay Service
ProtocolSDS
Application
- For quantitative determination of phosphate and evaluation of drug effects on phosphate metabolism.
Key Features
- Sensitive and accurate. Linear detection range 0.3 μM (0.0028 mg/dL) to 50 μM (0.47 mg/dL) phosphate in 96-well plate assay.
- Simple and high-throughput. The procedure involves addition of a single working reagent and incubation for 30 min. Can be readily automated as a high-throughput assay for thousands of samples per day.
- Improved reagent stability and versatility. The optimized formulation has greatly enhanced reagent and signal stability. Assays can be executed in cuvet or 96-well plate.
- Low interference in biological samples. No pretreatments are needed. Assays can be directly performed on raw biological samples i.e., in the presence of lipid, protein and minerals.
Method
- OD620nm (malachite green)
Samples
- Serum, urine, saliva, sweat, tissue culture, food, environment etc
Species
- All
Size
- 500 tests
Detection Limit
- 3 μg/dL (0.3 μM)
Shelf Life
- 12 months
More Details
- Phosphate(Pi) is one of the most important ion species in nature. Phosphate is present in all biological systems. It is a major constituent in minerals and fertilizers, and is a component of industrial wastewater. Thus accurate determination of phosphate concentration finds numerous applications in pharmacology, biomedical research, clinical chemistry, industrial process monitoring and environmental monitoring. Simple, direct and automation-ready procedures for measuring phosphate concentration in biological and environmental samples are becoming popular. BioAssay Systems phosphate assay kit is designed to measure phosphate ion directly in samples without any pretreatment. The improved Malachite Green method utilizes the malachite green dye and molybdate, which forms a stable colored complex specifically with inorganic phosphate. The intensity of the color, measured at 620nm, is directly proportional to the phosphate concentration in the sample. The optimized formulation substantially reduces interference by substances in the raw samples.
Is the assay able to detect condensed phosphate?
Our assays detect ortho-phosphate only. Condensed phosphates such as pyrophosphate or other polyphosphates first have to be hydrolyzed in order to be detected. In aqueous solutions condensed phosphates will gradually hydrolyze into ortho-phosphate depending on their concentration. Thus, when using samples that contain condensed phosphates in solution only the part that has been already completely hydrolyzed into ortho-phosphate will be detected. If the user wants to determine the total phosphate content of the sample, condensed phosphates have to be completely hydrolyzed (e.g. by acidification) before assaying.Can #DIPI-500 can be used for measuring the phosphate concentration in in edible meat? If you have the any information about sample preparation for solid sample, please let us know.
We have not validated the kit with meat samples but it will work just fine. - If you want to measure free inorganic phosphate, I would suggest homogenizing the sample in water, centrifuging the homogenate and using the clear supernatant for the assay.- If you want to measure total phosphate content in meat, you have to first digest the sample, e.g. with nitric acid first, then filter the digest and use the neutralized digest in the assay.I would like to have an information concerning the Malachite Green Phosphate Assay Kits. I am not sure if it is possible to detect the liberation of Pi from activated amino sugars without hydrolysation of the activated groups (e.g. because of acidic conditions).
The POMG-05K kit contains 12% sulfuric acid, which when diluted in your reaction mixture is 2.4% sulfuric acid. As the color reaction is completed within 10 min, the hydrolysation of the activated groups may not be so fast, if it happens. However, as we have not done this test here, you could check it by doing a pilot experiment: mixing 2.4% sulfuric acid with your substrate for 10, 20, 30 min, analysis the reaction mixture on HPLC to see if there is any hydrolysation.Could you tell us if this kit can be used for samples in acidic solution (HCl, H2SO4, and 10%TCA)?
Our kit can be used with acidic samples. But make sure that the acid does not contain phosphate. HCl and H2SO4 are fine. TCA usually contains residual phosphate. 10% TCA may contain 20 μM Phosphate ion, so this would give higher background. It may be used, but a "sample" control containing the same amount of TCA must be assayed together and subtracted from the sample value. It is recommended to dilute the sample containing TCA prior to the assay, so the amount of TCA is less than e.g. 2%.What is the difference between your 3 phosphate assays: DIPI-500, POMG-25H, POPB-500?
All three products are based on the malachite green dye. While the PiBlue (POPB-500) and QuantiChrom (DIPI-500) Phosphate Assay Reagents are identical, they differ in the standards. The PiBlue is designed for customers who want prepare a full calibration curve for their assays, and the latter has one set of a blank control and 30 µM phosphate standard. The reagent is more diluted than the reagent used in the Malachite Green Phosphate Assay Kit (POMG-25H). As a result, one adds 100 µL reagent (POPB-500 or DIPI-500) to 50 µL sample, whereas for the Malachite Green based assay, one adds 20 µL Reagent to 80 µL sample. In practice, the DIPI-500 is the most convenient kit to use, because there is no need to prepare a calibration curve there is no need for extra mixing. Because adding a larger volume (100 μL) to a small volume (50 μL) effects efficient mixing in well, no extra mixing is needed. The POPB-500 requires preparation of calibration curve. With the POMG-25H Kit, one needs to mix the reagent with the sample, because adding 20 µL to 80 µL does not mix efficiently by itself. Also a preparation of a standard curve is necessary.For more detailed product information and questions, please feel free to Contact Us. Or for more general information regarding our assays, please refer to our General Questions.Al-Saiedy, M., Gunasekara, L., Green, F., Pratt, R., Chiu, A., Yang, A. & Amrein, M. (2018). Surfactant Dysfunction in ARDS and Bronchiolitis is Repaired with Cyclodextrins. Military medicine, 183(suppl_1), 207-215. Assay: Phosphate in bovine lipid. Dai, J., Lai, L., Tang, H., Wang, W., Wang, S., Lu, C. & Wu, Z. (2018). Streptococcus suis synthesizes deoxyadenosine and adenosine by 5"-nucleotidase to dampen host immune responses. Virulence, 9(1), 1509-1520. Assay: Phosphate in mouse blood. Shamsuzzaman, S., Onal, M., St John, H. C., Jeffery, J. J., & Pike, J. W. (2017). Absence of the vitamin D receptor inhibits atherosclerotic plaque calcification in female hypercholesterolemic mice. Journal of cellular biochemistry, 118(5), 1050-1064. Assay: Phosphate in fish serum. Subramaniyan, S. A., Da Rae Kang, S. A. B., Eun-So-Ri Cho, J. H., Jung, Y. C. J., Choi, Y. I., & Shim, K. S. (2016). Meat quality and physicochemical trait assessments of berkshire and commercial 3-way crossbred pigs. Korean journal for food science of animal resources, 36(5), 641. Assay: Phosphate in pig tissue. Villa-Bellosta, R., Gonzalez-Parra, E., & Egido, J. (2016). Alkalosis and dialytic clearance of phosphate increases phosphatase activity: a hidden consequence of hemodialysis. PloS one, 11(7), e0159858. Assay: Phosphate in human plasma. Ballester-Lozano GF et al. (2015). Comprehensive biometric, biochemical and histopathological assessment of nutrient deficiencies in gilthead sea bream fed semi-purified diets. Br J Nutr. 114(5):713-26. Assay: phosphate in fish plasma. Dunbar, DR. et al (2010). Transcriptional and physiological responses to chronic ACTH treatment by the mouse kidney. Physiol Genomics. 40(3):158-66. Assay: Phosphate in mouse urine. Galitzer H, et al (2010). Parathyroid cell resistance to fibroblast growth factor 23 in secondary hyperparathyroidism of chronic kidney disease. Kidney Int.77(3):211-8. Assay: Phosphate in rat serum. Ponda MP, et al (2010). Moderate kidney disease inhibits atherosclerosis regression. Atherosclerosis. 210(1):57-62. Assay: Phosphate in mouse tissue. Xie J et al (2010). Comparison of media used to evaluate Rhizobium leguminosarum bivar viciae for phosphate-solubilizing ability. Can J Microbiol. 55(7):910-5. Assay: Phosphate in Plant tissue.Dunbar, DR et al (2009). Transcriptional and physiological responses to chronic ACTH treatment by the mouse kidney. Physiol Genomics. 40(3):158-66. Assay: Phosphate in mouse urine.Hildebrand, J. et al (2009) Functional and energetic characterization of P-gp-mediated doxorubicin transport in rainbow trout (Oncorhynchus mykiss) hepatocytes Comp Biochem Physiol C Toxicol Pharmacol. 149(1):65-72. Assay: Phosphate in fish hepatocyte. O"Connor RD, et al (2009). Mecp2 deficiency decreases bone formation and reduces bone volume in a rodent model of Rett syndrome. Bone. 45(2):346-56. Assay: Phosphate in mouse tissue. Xie J, et al (2009). Comparison of media used to evaluate Rhizobium leguminosarum bivar viciae for phosphate-solubilizing ability. Can J Microbiol. 55(7):910-5. Assay: Phosphate in plant tissue. Abranches, J. (2008). CcpA regulates central metabolism and virulence gene expression in Streptococcus mutans. J Bacteriol. 190(7):2340-9. Assay: Phosphate in bacteria cellular ATPase. Jubeck B, et al (2008). Promotion of articular cartilage matrix vesicle mineralization by type I collagen. Arthritis Rheum. 58(9):2809-17. Assay: Phosphate in human collagen. Chung YI, et al (2007). Enhanced bone regeneration with BMP-2 loaded functional nanoparticle-hydrogel complex. J Control Release 121(1-2):91-9. Assay: Phosphate in rat bone.To find more recent publications, pleaseclick here.
If you or your labs do not have the equipment or scientists necessary to run this assay, BioAssay Systems can perform the service for you.Simply send us your samples:- Fast turnaround - Quality data - Low costPlease email or call 1-510-782-9988 x 2 to request assay service.
蚂蚁淘电商平台
ebiomall.com
ebiomall.com
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台,
该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁
淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、
运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯
蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧
蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事
蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务
蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
2021-09-11
不锈钢病理取材台是由内蒙古实验家具供应厂家代理或销售的德尔品牌的仪器,产品来源于北京。内蒙古实验家具供应厂家是中国最权威的不锈钢病理取材台销售服务商之一,在北京等地方销售不锈钢病理取材台已经多年。同时,生物在线为您提供众多企业不锈钢病理取材台仪器产品及图片,以便挑选到性价比高,合适的不锈钢病理取材台产品 查看更多
>
广州市凯秀贸易有限公司经销批发的包埋盒、宫颈刷、莱卡刀片、石蜡、标本袋畅销消费者市场,在消费者当中享有较高的地位,公司与多家零售商和代理商建立了长期稳定的合... 查看更多
>
2019-08-09
广州市凯秀贸易有限公司经销批发的包埋盒、宫颈刷、莱卡刀片、石蜡、标本袋畅销消费者市场,在消费者当中享有较高的地位,公司与多家零售商和代理商建立了长期稳定的合... 查看更多
>
2018-03-24
江苏省捷达科技发展有限公司在发布的皮肤真菌病理图像与信息管理系统供应信息,浏览与皮肤真菌病理图像与信息管理系统相关的产品或在搜索更多与皮肤真菌病理图像与信息管理系统相关的内容。 查看更多
>
2021-09-07
品牌名:德国类型:其他实验耗材病理耗材,北京利康盛达科技发展有限公司病理实验室设备耗材订货电话13269478636编... 英国珊顿刀片和徕卡包埋剂、樱花OCT包埋剂、珊顿冰冻包埋剂及莱卡切片石蜡... 查看更多
>
伯舒纳Personna病理切片一次性刀片和美国樱花SAKURA、德国徕卡Leica、英国珊顿Shandon、美国美克McCormick冷冻切片包埋剂O.C.T及德国莱卡Leica切片石... 查看更多
>
2021-08-09
近日,由中华医学会《中华病理学杂志》编辑委员会和中华医学会病理学分会主办,《白血病·淋巴瘤》杂志协办的第十八届全国诊断病理暨淋巴造血组织疾病病理学术研讨会在太原开幕。在此次大会上,国家卫计委病理质量控制中心(以下简称 PQCC)主任陈杰教授与质控中心免疫组化质控组长卢朝辉教授分别做了题为《2015 年国家病理科医疗质量报告》和《病理科免疫组织化学实验室管理及质控规范》的主题报告,借此机会,丁香园就中国病理科建设与质控的话题与两位教授... 查看更多
>
2021-08-07
FDA批准首个用于数字病理学的全切片影像系统 查看更多
>
2018-03-14
宫颈癌发病率高,是影响妇女健康的主要疾病,降低宫颈癌危害的有效方法是广泛开展宫颈癌的筛查与宫颈病变的早诊早治。为加强我国妇产科医师执业水平,规范执业,提高行业自律能力,中国医师协会妇产科分会教育学院,成立了宫颈病变与细胞病理学分院,学院的宗旨是:开展学术研究,规范执业操作,加强人员培训,促进宫颈癌防治深入发展。为促进宫颈癌的筛查项目的正常进行,培训相关技术人员,推进宫颈癌防治的深入发展,会后将举办细胞病理学和阴道镜培训班,培训班将按照统... 查看更多
>
2018-02-14
湖北徕克医疗仪器有限公司在发布的密集柜、病理密集柜、密集病理切片蜡块档案柜供应信息,浏览与密集柜、病理密集柜、密集病理切片蜡块档案柜相关的产品或在搜索更多与密集柜、病理密集柜、密集病理切片蜡块档案柜相关的内容。 查看更多
>
2018-04-02
广州英伦净化工程公司是华南地区空气净化工程、无尘车间、洁净室行业的龙头企业,系集无尘净化工程,无尘车间装修,洁净室,无尘室,gmp净化厂房,洁净厂房,gmp洁净车间,净化车间等空调洁净工程的设计施工及服务于一体的洁净室行业系统解决方案提供商。" />