请使用支持JavaScript的浏览器! Signosis/Mouse Cytokine cDNA Plate Array/AP-1141/1 Ea-蚂蚁淘商城
新闻动态

Signosis/Mouse Cytokine cDNA Plate Array/AP-1141/1 Ea

  
  2025-05-06
  

Description:

Cytokines are essential molecules that play crucial roles in many biological functions, including viral infection, inflammation, immunity, and hematopoiesis. Cytokines are produced by a variety of cell types in response to different stimuli. In addition, the expression of cytokine genes appears to be regulated by complex mechanism. Expression of one cytokine gene could be regulated by other cytokines. Dysregulation of cytokine gene expression may be caused by chromosomal alterations or by infection of viruses that induce activation or inactivation of the expression machinery. Therefore, expression profiling of cytokine genes could provide a useful approach to uncover the mechanism underlying their regulation.

Applicable Grid:

List of Applicable Genes

123456789101112A18S rRNAIL-13IL-418S rRNAIL-13IL-418S rRNAIL-13IL-418S rRNAIL-13IL-4BEotaxinIL-14IL-5EotaxinIL-14IL-5EotaxinIL-14IL-5EotaxinIL-14IL-5CGAPDHIL-15IL6GAPDHIL-15IL6GAPDHIL-15IL6GAPDHIL-15IL6DIFNbIL-16IL-7IFNbIL-16IL-7IFNbIL-16IL-7IFNbIL-16IL-7EIFNgIL-17TGFaIFNgIL-17TGFaIFNgIL-17TGFaIFNgIL-17TGFaFIL-10IL1ATGFbIL-10IL1ATGFbIL-10IL1ATGFbIL-10IL1ATGFbGIL11IL2TNFaIL11IL2TNFaIL11IL2TNFaIL11IL2TNFaHIL-12IL-3VEGFCIL-12IL-3VEGFCIL-12IL-3VEGFCIL-12IL-3VEGFC

Principle:

Signosis’ proprietary cDNA plate array is a plate-based hybridization profiling analysis for monitoring the expression of dozens of genes through reverse transcription of mRNA into cDNA. Like array analyses, total RNA is first reverse transcribed into cDNA in the presence of biotin-dUTP in the assay. Targeted genes are then specifically captured onto individual wells on a plate, instead of membranes, through a pre-coated gene-specific oligonucleotide. The captured cDNAs are further detected with streptavidin-HRP. Luminescence is reported as relative light units (RLUs) on a microplate luminometer. The expression level of genes is directly proportional to the luminescent intensity.\"\"

Data:

\"\"Mouse cytokine cDNA plate array analysis. NIH3T3 cells were treated with (red bars) or without (light blue) 10ng/ml TNF for 90 min. Cells were collected for profiling 23 genes with the cDNA plate array assay.

本文链接: https://www.ebiomall.cn/b327-signosis/info-1591167412.html

免责声明 本文仅代表作者个人观点,与本网无关。其创作性以及文中陈述文字和内容未经本站证实,对本文以及其中全部或者部分内容、文字的真实性、完整性、及时性本站不做任何保证或承诺,请读者仅作参考,并请自行核实相关内容。
版权声明 未经蚂蚁淘授权不得转载、摘编或利用其他方式使用上述作品。已经经本网授权使用作品的,应该授权范围内使用,并注明“来源:蚂蚁淘”。违反上述声明者,本网将追究其相关法律责任。
没有了