Description
During the past five decades, various types of chemistries have been used for conjugation of molecules such as antibodies, peptides, proteins or other reactive ligands to the surface of liposomes. In general, the conjugation can be achieved through the N-terminus, the C-terminus or the available sulfur (e.g. Fab’ fraction or thiolated antibodies). Not all chemistries have the same yield and efficiency of conjugation and often reproducing biocompatible batches can be a challenge.
Folate binding protein (FBP) is an endogenous protein, which shows a very high affinity for folate. An antibody can be tagged by FBP and an immunoliposome can be formed by non-covalent and high affinity interaction between FBP and folate lipid on the surface of the liposomes. In this method, the antibody, which has been already covalently linked to FBP through a thioether linkage, is conjugated with folate-derivative liposomes. Having a relatively low molecular weight (MW ∼40 kDa) and a single binding site prevents liposomes from crosslinking.
Immunosome®-Folate is a PEGylated product. For the other reactive (PEGylated and non-PEGyalated products) Immunosome® products suitable for other types of conjugation method see here.
Formulation Information
Immunosome®-Folate (PEGylated)
| Lipid Composition | Concentration (mg/ml) | Concentration (mM) | Molar Ratio Percentage |
|---|---|---|---|
| Total | 15.86 mg/ml | 21.55 mM | 100 |
| Hydrogenated Soy PC | 9.58 | 12.22 | 57 |
| Cholesterol | 3.19 | 8.25 | 38 |
| DSPE-PEG(2000) | 2.7 | 0.96 | 4.5 |
DSPE-PEG(2000)-Folate![]() | 0.39 | 0.12 | 0.5 |
| Buffer and Liposome Size | Specification |
|---|---|
| Buffer | Phosphate Buffered Saline |
| pH | 7.4 |
| Liposome Size | 100 nm |
Conjugation Protocol
Materials and Equipment
In order to conjugate your antibody or protein tagged with FBP to Immunosome®-Folate liposomes you will need:
- Laboratory vortex mixer is recommended to have.
- Laboratory magnetic stirrer is needed for dialysis.
- Float-A-Lyzer® with a proper MWCO that easily allows the cleanup of your liposome conjugated ligand from free and non-conjugated protein/peptide/ligand. You need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore your liposomes can be dialyzed out. You cannot use dialysis cassettes blindly. Please understand the technique before using either spin column or dialysis cassette. If you do not use the correct MWCO, you can lose your entire prep. For this protocol, we recommend MWCO of 300,000 dalton.
Preparation Method
- The total lipid concentration in Immunosome®-Folate is 21.55 mM. 0.5% mol of the lipid in liposomes contains PEG-Folate group and only half of them are exposed to the outside of the liposomes, which is equal to 0.053 mM of reactive conjugatable lipid. For 2 ml volume liposomes, this is equal to 1.08×10-7 mol, and for 5 ml volume liposomes, this is equal to 2.69×10-7 mol of PEG-Folate. Add 1:20 molar ratio of antibody tagged with FBP to PEG-Folate lipid.
- Incubate Immunosome®-Folate with antibody-FBP for 1 hour at room temperature.
- Remove non-conjugated antibody, protein, peptide or ligand by dialysis. We prefer dialysis to size exclusion columns. Dialysis is a much slower process but there will be minimum loss of immunoliposomes after the prep is cleaned from non-conjugated protein/peptide/ligand. Spin columns are much faster but you can easily lose over 50% of the liposomes on the spin column. We recommend using Float-A-Lyzer® dialysis cassette from Spectrum Labs. You need to choose a cassette with proper MWCO depending on the MW of your protein, ligand, antibody or antibody fragment. NOTE: If you decide to use a dialysis cassette you need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore your liposomes can be dialyzed out. You cannot use dialysis cassettes and spin columns blindly. They come in various sizes and you need to choose the correct size wisely. Dialyze the immunoliposome solution in 1 liter of PBS at pH 7.4 for 8 hours. Change the dialysis buffer with a fresh 1 liter of PBS and let is dialyze for another 8 hours. After this step, your cleaned up immunoliposome is ready to be used. If you do not use the correct MWCO, you can lose your entire prep.
Liposome Particle Calculator
Immunosomes are unilamellar liposomes and sized to 100 nm. The molar concentration of liposome is 21.55 mM. By having liposome diameter (nm) and lipid concentration (µM), you can calculate the total number of the lipids in one liposome and the number of the liposomes in one milliliter of the liposome solution. To use the calculator click here.
Technical Notes
- Please keep in mind that the main using for liposomes containing folate on surface is for targeting folate receptors on the cells. Making immunoliposomes using antibodies/proteins or ligands tagged with FBP is a very niche application.
- The immunoliposomes may disassemble following internalization by endocytosis upon exposure to the low pH environment of the endosomal compartment, due to reduced affinity between folate and FBP under low pH. This internalization-triggered uncoupling may be beneficial to delivery of liposomal drug at the cellular level by allowing the sorting of the internalized liposomes to the appropriate subcellular compartment and/or facilitating intracellular release of drug molecules from the liposomes.
- Size exclusion spin columns such as Sepharose® CL-4B can be used instead of Float-A-Lyzer® dialysis cassette. However, a very large amount of liposomes will stick to the column during the cleanup process and therefore we strongly suggest using dialysis than size exclusive beads.
- If you are using a ligand or peptide that is hydrophobic then it is recommended to solubilize it in DMSO or DMF and then add the buffer to it. It is recommended not to use more than 5% volume of DMSO or DMF in the solution. DMF and DMSO are both compatible with liposomes and they are also miscible in water. Other organic solvent such as ethanol and chloroform are not compatible with liposomes and will cause the liposomes to lyse. If you end up using DMSO or DMF then after the conjugation reaction is done, you need to remove DMSO and DMF from the liposomes. In order to do that you need to use a dialysis cassette that is made from REGENERATED CELLULOSE MEMBRANE. NOTE: Not all membranes are compatible with DMF and DMSO. We recommend using a Slide-A-Lyzer™ MINI Dialysis Device with MWCO of 2K made from regenerated cellulose membrane manufactured by ThermoFisher. After DMSO or DMF is removed, you can use Float-A-Lyzer® dialysis device for the final step of cleaning up the prep.
- Liposomes should be kept at 4°C and NEVER be frozen.
Database
Direct link to the database page for easy navigation: Immunoliposomes Conjugation Database
Appearance
Immunosome®-Folate is a white translucent liquid made of nano size unilamellar liposomes. Usually due to the small size of liposomes no settling will occur in the bottom of the vial. The liposomes are packaged in an amber vial.
Ordering/Shipping Information
- All liposome based formulations are shipped on blue ice at 4°C in insulated packages using overnight shipping or international express shipping.
- Liposomes should NEVER be frozen. Ice crystals that form in the lipid membrane can rupture the membrane, change the size of the liposomes and cause the encapsulated drug to leak out. Liposomes in liquid form should always be kept in the refrigerator.
- Clients who order from outside of the United States of America are responsible for their government import taxes and customs paperwork. Encapsula NanoSciences is NOT responsible for importation fees to countries outside of the United States of America.
- We strongly encourage the clients in Japan, Korea, Taiwan and China to order via a distributor. Tough customs clearance regulations in these countries will cause delay in custom clearance of these perishable formulations if ordered directly through us. Distributors can easily clear the packages from customs. To see the list of the distributors click here.
- Clients ordering from universities and research institutes in Australia should keep in mind that the liposome formulations are made from synthetic material and the formulations do not require a “permit to import quarantine material”. Liposomes are NOT biological products.
- If you would like your institute’s FedEx or DHL account to be charged for shipping, then please provide the account number at the time of ordering.
- Encapsula NanoSciences has no control over delays due to inclement weather or customs clearance delays. You will receive a FedEx or DHL tracking number once your order is confirmed. Contact FedEx or DHL in advance and make sure that the paperwork for customs is done on time. All subsequent shipping inquiries should be directed to Federal Express or DHL.
Storage and Shelf Life
Storage
Immunosome® products should always be stored at in the dark at 4°C, except when brought to room temperature for brief periods prior to animal dosing. DO NOT FREEZE. If the suspension is frozen, the encapsulated drug can be released from the liposomes thus limiting its effectiveness. In addition, the size of the liposomes will also change upon freezing and thawing.
Shelf Life
Immunosome®-Folate is made on daily basis. The batch that is shipped is manufactured on the same day. It is advised to use the products within 4 months of the manufacturing date.
Reference and background reading
Pan X, Lee RJ. Construction of anti-EGFR immunoliposomes via folate–folate binding protein affinity. International journal of pharmaceutics. 2007 May 24;336(2):276-83.
ebiomall.com
>
>
>
>
>
>
>
>
>
>
>
>
GFP发出绿色荧光的原理是Ca离子进入GFP的beta-barrel结构中引起的特定能级,因此只要这个结构仍然保持着,就可以发出荧光。
由于GFP的beta-barrel结构非常稳定,一些版本的GFP蛋白(如EGFP)甚至能抵抗94C的高温几分钟而不完全变性,因此想在溶液状态下去掉GFP的荧光是很难的,一般需要用光漂白法。
基于其非常稳定的结构,即便细胞被固定了,仍然会有一部分的GFP蛋白保持其构象而发出荧光。此时荧光可能较弱。在荧光显微镜下是有可能看得到的。
DXY721认为:
悬浮细胞和贴壁细胞在转染过程中差别不大,主要差别在于转染后的筛选,当然如果你做的是瞬时转染就不存在筛选的问题了。
其实转染的过程很简单,问题是能不能转的进去的,转染率能有多少,转进去是否可以稳定表达目的蛋白等等。
我们也是用脂质体做悬浮细胞的转染,说明书上都有具体的操作过程,将脂质体和目的基因按比例混合,然后加到细胞悬液里就OK了,说的简单,实际上还是有一些细节要注意的,比如脂质体和目的基因混合的比例,转染的细胞数,细胞的代数,细胞的状态,有的还要求在转染的前一天传代一次,不过不要怕,这些在脂质体说明书上都有明确的说明,按照说明书做就可以了。
jinghuanlv认为:
悬浮细胞和贴壁细胞转染还是有很大不同的。
脂质体转染的原理基于电荷吸引原理,先形成脂质体-DNA复合物,散布在细胞周围,然后通过细胞的内吞作用,将目的基因导入细胞内,而脂质体复合物与贴壁细胞的接触机会比悬浮细胞高出很多倍,所以,脂质体转染时悬浮细胞的转染效率要明显低于贴壁细胞。
我们实验室转染悬浮细胞是用的电穿孔法,目前为止,悬浮细胞转染的最好方法还是电转,我们实验室用的电转仪是Bio-Rad的,使用条件是电压250V,电容975uF,效果不错,不妨一用。
做的比较好的,一般都是上海地区的,你可以看下基尔顿生物。
目标蛋白对细胞有毒性,导致细胞死亡;
转染试剂以及DNA用量信息需要优化,否则对细胞具有伤害;
细胞贴壁转染之后没有正常换液。
建议:考虑对目标蛋白进行截短构建、尝试其他细胞系统;摸索转染试剂以及DNA用量信息,如果转染试剂毒性太大,可以考虑尝试义翘转染试剂sinofection;对转染后的细胞进行换液处理,如果细胞状态感觉不够理想,可以考虑添加一些血清来帮助细胞恢复健康。
以上所有分析、建议的前提是,细胞培养、无菌操作等等都没有问题。祝顺利,加油~
脂质体是磷脂分散在水中时形成的脂质双分子层,又称为人工生物膜。
阳离子脂质体表面带正电荷,能与核酸的磷酸根通过静电作用将DNA分子包裹入内,形成DNA一脂复合体,也能被表面带负电荷的细胞膜吸附,再通过膜的融合或细胞的内吞作用,偶尔也通过直接渗透作用,DNA传递进入细胞,形成包涵体或进入溶酶体 其中一小部分DNA能从包涵体内释放,并进入细胞质中,再进一步进入核内转录、表达。
影响转染试验的因素:
1转染试剂跟细胞系不匹配
转染试剂跟细胞系也是讲究配合默契的,使用同一种试剂,不同细胞系转染效率通常不同。但细胞系的选择通常是根据实验的需要,因此在转染实验前应根据实验要求和细胞特性选择适合的转染试剂。每种转染试剂都会提供一些已经成功转染的细胞株列表和文献,通过这些资料可选择最适合实验设计的转染试剂。当然,最适合的是高效、低毒、方便、廉价的转染试剂。
2细胞状态变化
因为有些细胞系是不稳定的,可能随着培养时间的改变,培养条件的不同,不同的选择压力,可能引起不同的克隆选择。因此就算是同一个细胞系,在不同条件下转染能力的差异可能会
很大
(1)转染试剂与细胞不匹配
细胞转染最适合的不是原代细胞,也不是传代很多次的细胞。这是因为细胞培养在实验室中保存数月和数年后会经历突变,总染色体重组或基因调控变化等而演化。这会导致和转染相关的细胞行为的变化。最适合转染的细胞是经过几次传代后达到对数生长期的细胞,细胞生长旺盛,最容易转染。
(2)把握时机
没错!转染也有适当的时机,相比较非分裂细胞——分裂细胞往往要比静止细胞更易于摄取并表达外源DNA。因此对大多数转染操作而言,细胞都在转染当天或前一天种板。
同样重要的是细胞在种板进行转染时不应处于过度生长的状态,如癌细胞数量过多,互相叠加,营养物质耗竭,代谢废物积聚,转染率低下也是很正常的!
因此,一定要在最适细胞密度时转染,才能获得较高的转染率。不同的转染试剂,要求转染时的最适细胞密度各不相同,即使同一种试剂,也会因不同的细胞类型或应用而异。
(3)微生物来捣乱
培养物可被细菌、酵母、真菌、病毒、支原体、甚至其他细胞种类所污染。各种污染都会导致产生错误的结果。
(4)交叉污染
如果同一个实验室同时培养不同种类的细胞,很同意发生“细胞串门”的现象,造成交叉污染。
3转染方法
不同转染试剂有不同的转染方法,但大多大同小异。转染时应跟据具体转染试剂推荐的方法,但也要注意,因不同实验室培养的细胞性质不同,质粒定量差异,操作手法上的差异等,其转染效果可能不同,应根据实验室的具体条件来确定最佳转染条件。
(1)血清
转染后未及时加入血清,会导致细胞大量死亡。一般要在转染后的4-6小时换液且换为有血清的培养基。也可以在原来的无血清培养基里面滴加血清。这个时候,最好不要换液,不要打扰细胞,让它安安静静地休息。但是也不能过早加入血清。过早的话,会引起未转染的细胞疯狂生长。那么,什么是最佳时机呢?在20%的细胞变圆的时候,就是加血清的最佳时机。
不过要特别注意:血清是一种包含生长因子及其它辅助因子的不确切成分的添加物,对不同细胞的生长作用有很大的差别。血清质量的变化直接影响细胞生长,因此也会影响转染效率。新加培养基的预热对细胞转染很有帮助。
(2)DNA质量
DNA质量对转染效率影响非常大。一般的转染技术(如脂质体等)基于电荷吸引原理,如果DNA不纯,如带少量的盐离子,蛋白,代谢物污染都会显著影响转染复合物的有效形成及转染的进行。
4载体构建
转染载体的构建(病毒载体,质粒DNA,RNA,PCR产物,寡核苷酸等)也影响转染结果。因此选择组成或可调控,强度合适的启动子也很重要,同时做空载体及其它基因的相同载体构建的转染正对照可排除毒性影响的干扰。
所以转染用的质粒首先要保证数量,一般为2μg以上。质粒纯度不够或者含有细菌LPS或其他对细胞有毒害作用的物质,也会影响转染效率。这个时候,就应该对质粒进行纯化和浓缩。
以上就是细胞转染率低的主要原因了,在实验过程中有没有遇到什么棘手的问题呢,欢迎留言讨论
其次要看下你选择单位的规模如何,做的比较好的,还是上海这边的,你可以看下基尔顿生物,原代细胞培养,动物造模,整体课题外包。