
Description
During the past five decades, various types of chemistries have been used for conjugation of molecules such as antibodies, peptides, proteins or other reactive ligands to the surface of liposomes. In general, the conjugation can be achieved through the N-terminus, the C-terminus or the available sulfur (e.g. Fab’ fraction or thiolated antibodies). Not all chemistries have the same yield and efficiency of conjugation and often reproducing biocompatible batches can be a challenge.
Folate binding protein (FBP) is an endogenous protein, which shows a very high affinity for folate. An antibody can be tagged by FBP and an immunoliposome can be formed by non-covalent and high affinity interaction between FBP and folate lipid on the surface of the liposomes. In this method, the antibody, which has been already covalently linked to FBP through a thioether linkage, is conjugated with folate-derivative liposomes. Having a relatively low molecular weight (MW ∼40 kDa) and a single binding site prevents liposomes from crosslinking.
Immunosome®-Folate is a PEGylated product. For the other reactive (PEGylated and non-PEGyalated products) Immunosome® products suitable for other types of conjugation method see here.
Formulation Information
Immunosome®-Folate (PEGylated)
Lipid Composition | Concentration (mg/ml) | Concentration (mM) | Molar Ratio Percentage |
---|---|---|---|
Total | 15.86 mg/ml | 21.55 mM | 100 |
Hydrogenated Soy PC | 9.58 | 12.22 | 57 |
Cholesterol | 3.19 | 8.25 | 38 |
DSPE-PEG(2000) | 2.7 | 0.96 | 4.5 |
DSPE-PEG(2000)-Folate![]() | 0.39 | 0.12 | 0.5 |
Buffer and Liposome Size | Specification |
---|---|
Buffer | Phosphate Buffered Saline |
pH | 7.4 |
Liposome Size | 100 nm |
Conjugation Protocol
Materials and Equipment
In order to conjugate your antibody or protein tagged with FBP to Immunosome®-Folate liposomes you will need:
- Laboratory vortex mixer is recommended to have.
- Laboratory magnetic stirrer is needed for dialysis.
- Float-A-Lyzer® with a proper MWCO that easily allows the cleanup of your liposome conjugated ligand from free and non-conjugated protein/peptide/ligand. You need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore your liposomes can be dialyzed out. You cannot use dialysis cassettes blindly. Please understand the technique before using either spin column or dialysis cassette. If you do not use the correct MWCO, you can lose your entire prep. For this protocol, we recommend MWCO of 300,000 dalton.
Preparation Method
- The total lipid concentration in Immunosome®-Folate is 21.55 mM. 0.5% mol of the lipid in liposomes contains PEG-Folate group and only half of them are exposed to the outside of the liposomes, which is equal to 0.053 mM of reactive conjugatable lipid. For 2 ml volume liposomes, this is equal to 1.08×10-7 mol, and for 5 ml volume liposomes, this is equal to 2.69×10-7 mol of PEG-Folate. Add 1:20 molar ratio of antibody tagged with FBP to PEG-Folate lipid.
- Incubate Immunosome®-Folate with antibody-FBP for 1 hour at room temperature.
- Remove non-conjugated antibody, protein, peptide or ligand by dialysis. We prefer dialysis to size exclusion columns. Dialysis is a much slower process but there will be minimum loss of immunoliposomes after the prep is cleaned from non-conjugated protein/peptide/ligand. Spin columns are much faster but you can easily lose over 50% of the liposomes on the spin column. We recommend using Float-A-Lyzer® dialysis cassette from Spectrum Labs. You need to choose a cassette with proper MWCO depending on the MW of your protein, ligand, antibody or antibody fragment. NOTE: If you decide to use a dialysis cassette you need to make sure that the MWCO is below 1,000,000 dalton. At 1,000,000 dalton, the pore size on the dialysis membrane gets close to 100 nm and therefore your liposomes can be dialyzed out. You cannot use dialysis cassettes and spin columns blindly. They come in various sizes and you need to choose the correct size wisely. Dialyze the immunoliposome solution in 1 liter of PBS at pH 7.4 for 8 hours. Change the dialysis buffer with a fresh 1 liter of PBS and let is dialyze for another 8 hours. After this step, your cleaned up immunoliposome is ready to be used. If you do not use the correct MWCO, you can lose your entire prep.
Liposome Particle Calculator
Immunosomes are unilamellar liposomes and sized to 100 nm. The molar concentration of liposome is 21.55 mM. By having liposome diameter (nm) and lipid concentration (µM), you can calculate the total number of the lipids in one liposome and the number of the liposomes in one milliliter of the liposome solution. To use the calculator click here.
Technical Notes
- Please keep in mind that the main using for liposomes containing folate on surface is for targeting folate receptors on the cells. Making immunoliposomes using antibodies/proteins or ligands tagged with FBP is a very niche application.
- The immunoliposomes may disassemble following internalization by endocytosis upon exposure to the low pH environment of the endosomal compartment, due to reduced affinity between folate and FBP under low pH. This internalization-triggered uncoupling may be beneficial to delivery of liposomal drug at the cellular level by allowing the sorting of the internalized liposomes to the appropriate subcellular compartment and/or facilitating intracellular release of drug molecules from the liposomes.
- Size exclusion spin columns such as Sepharose® CL-4B can be used instead of Float-A-Lyzer® dialysis cassette. However, a very large amount of liposomes will stick to the column during the cleanup process and therefore we strongly suggest using dialysis than size exclusive beads.
- If you are using a ligand or peptide that is hydrophobic then it is recommended to solubilize it in DMSO or DMF and then add the buffer to it. It is recommended not to use more than 5% volume of DMSO or DMF in the solution. DMF and DMSO are both compatible with liposomes and they are also miscible in water. Other organic solvent such as ethanol and chloroform are not compatible with liposomes and will cause the liposomes to lyse. If you end up using DMSO or DMF then after the conjugation reaction is done, you need to remove DMSO and DMF from the liposomes. In order to do that you need to use a dialysis cassette that is made from REGENERATED CELLULOSE MEMBRANE. NOTE: Not all membranes are compatible with DMF and DMSO. We recommend using a Slide-A-Lyzer™ MINI Dialysis Device with MWCO of 2K made from regenerated cellulose membrane manufactured by ThermoFisher. After DMSO or DMF is removed, you can use Float-A-Lyzer® dialysis device for the final step of cleaning up the prep.
- Liposomes should be kept at 4°C and NEVER be frozen.
Database
Direct link to the database page for easy navigation: Immunoliposomes Conjugation Database
Appearance
Immunosome®-Folate is a white translucent liquid made of nano size unilamellar liposomes. Usually due to the small size of liposomes no settling will occur in the bottom of the vial. The liposomes are packaged in an amber vial.
Ordering/Shipping Information
- All liposome based formulations are shipped on blue ice at 4°C in insulated packages using overnight shipping or international express shipping.
- Liposomes should NEVER be frozen. Ice crystals that form in the lipid membrane can rupture the membrane, change the size of the liposomes and cause the encapsulated drug to leak out. Liposomes in liquid form should always be kept in the refrigerator.
- Clients who order from outside of the United States of America are responsible for their government import taxes and customs paperwork. Encapsula NanoSciences is NOT responsible for importation fees to countries outside of the United States of America.
- We strongly encourage the clients in Japan, Korea, Taiwan and China to order via a distributor. Tough customs clearance regulations in these countries will cause delay in custom clearance of these perishable formulations if ordered directly through us. Distributors can easily clear the packages from customs. To see the list of the distributors click here.
- Clients ordering from universities and research institutes in Australia should keep in mind that the liposome formulations are made from synthetic material and the formulations do not require a “permit to import quarantine material”. Liposomes are NOT biological products.
- If you would like your institute’s FedEx or DHL account to be charged for shipping, then please provide the account number at the time of ordering.
- Encapsula NanoSciences has no control over delays due to inclement weather or customs clearance delays. You will receive a FedEx or DHL tracking number once your order is confirmed. Contact FedEx or DHL in advance and make sure that the paperwork for customs is done on time. All subsequent shipping inquiries should be directed to Federal Express or DHL.
Storage and Shelf Life
Storage
Immunosome® products should always be stored at in the dark at 4°C, except when brought to room temperature for brief periods prior to animal dosing. DO NOT FREEZE. If the suspension is frozen, the encapsulated drug can be released from the liposomes thus limiting its effectiveness. In addition, the size of the liposomes will also change upon freezing and thawing.
Shelf Life
Immunosome®-Folate is made on daily basis. The batch that is shipped is manufactured on the same day. It is advised to use the products within 4 months of the manufacturing date.
Reference and background reading
Pan X, Lee RJ. Construction of anti-EGFR immunoliposomes via folate–folate binding protein affinity. International journal of pharmaceutics. 2007 May 24;336(2):276-83.
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
我转的是7901、7901/DDP两种细胞,前者7901细胞很容易就转上,并且转后,状态良好,可是7901/DDP一转就死,我用的是吉玛慢病毒,转24小时后换液,刚开始一两天,没有异常,但后来细胞慢慢就死了,并且不是漂浮的,很多是贴着壁死,像是瓦解了一样
这是未转时细胞的样子
这是细胞转后,死亡的样子
并且即使是有些细胞未死,细胞后来也变得很脏,感觉有很破碎的细胞碎片
本人实验小白,**园子里大神指点,急,实在不知道怎么回事
细胞状态与密度;转染试剂的类型、用量;DNA的品质、用量;转染复合物的品质、作用细胞的时间长度。
GFP发出绿色荧光的原理是Ca离子进入GFP的beta-barrel结构中引起的特定能级,因此只要这个结构仍然保持着,就可以发出荧光。
由于GFP的beta-barrel结构非常稳定,一些版本的GFP蛋白(如EGFP)甚至能抵抗94C的高温几分钟而不完全变性,因此想在溶液状态下去掉GFP的荧光是很难的,一般需要用光漂白法。
基于其非常稳定的结构,即便细胞被固定了,仍然会有一部分的GFP蛋白保持其构象而发出荧光。此时荧光可能较弱。在荧光显微镜下是有可能看得到的。
DXY721认为:
悬浮细胞和贴壁细胞在转染过程中差别不大,主要差别在于转染后的筛选,当然如果你做的是瞬时转染就不存在筛选的问题了。
其实转染的过程很简单,问题是能不能转的进去的,转染率能有多少,转进去是否可以稳定表达目的蛋白等等。
我们也是用脂质体做悬浮细胞的转染,说明书上都有具体的操作过程,将脂质体和目的基因按比例混合,然后加到细胞悬液里就OK了,说的简单,实际上还是有一些细节要注意的,比如脂质体和目的基因混合的比例,转染的细胞数,细胞的代数,细胞的状态,有的还要求在转染的前一天传代一次,不过不要怕,这些在脂质体说明书上都有明确的说明,按照说明书做就可以了。
jinghuanlv认为:
悬浮细胞和贴壁细胞转染还是有很大不同的。
脂质体转染的原理基于电荷吸引原理,先形成脂质体-DNA复合物,散布在细胞周围,然后通过细胞的内吞作用,将目的基因导入细胞内,而脂质体复合物与贴壁细胞的接触机会比悬浮细胞高出很多倍,所以,脂质体转染时悬浮细胞的转染效率要明显低于贴壁细胞。
我们实验室转染悬浮细胞是用的电穿孔法,目前为止,悬浮细胞转染的最好方法还是电转,我们实验室用的电转仪是Bio-Rad的,使用条件是电压250V,电容975uF,效果不错,不妨一用。