请使用支持JavaScript的浏览器! Ossila/Methylammonium Iodidem / Hydroiodide, MAI | CAS 14965-49-2/10 g u003e99.9% purity/M271-10g_蚂蚁淘,【正品极速】生物医学科研用品轻松购|ebiomall 蚂蚁淘商城
商品信息
联系客服
Ossila/Methylammonium Iodidem / Hydroiodide, MAI | CAS 14965-49-2/10 g u003e99.9% purity/M271-10g
郑重提醒:
无质量问题不接受退换货,下单前请仔细核对信息。
下单后请及时联系客服核对商品价格,订单生效后再付款。
Ossila/Methylammonium Iodidem / Hydroiodide, MAI | CAS 14965-49-2/10 g u003e99.9% purity/M271-10g
品牌 / 
Ossila
货号 / 
M271-10g
美元价:
(友情提示:该价格仅为参考,欢迎联系客服询价!)
数    量:
免费咨询热线
4000-520-616

Methylammonium iodide (MAI), also referred to as methylamine hydroiodide, is a precursor for the synthesis of organic-inorganic hybrid perovskites for use in FETs, LEDs and PVs.

Applications

Due to the high purity of the methylammonium iodide (99.99%), it should be noted that its solubility is reduced within dimethyl formamide and dimethyl sulfoxide. This reduced solubility is due to the removal of trace amounts of residual hydroiodic acid (HI) used during the synthesis and purification of the material. This can potentially have an impact upon the performance of solar cells leading to a reduction in maximum power conversion efficiency achievable. Adding fixed concentrations of hydroiodic acid to perovskite solutions can allow for the improvement of device metrics[1-3]. Using high-purity precursor materials allows for accurate addition of amounts of hydroiodic acid giving higher reproducibility to experiments. It is recommended that between 1% and 10% hydroiodic acid is used with high-purity methylammonium iodide to achieve optimal device performance. The amount required depends on the precursors used, solution concentration, solvent used, and processing environment. Therefore, this will need to be adjusted for each individual laboratory and process.

For simpler ink fabrication, it is recommended that the lower-purity methylammonium iodide (>98%) is used.

  1. Hysteresis-less inverted CH3NH3PbI3 planar perovskite hybrid solar cells with 18.1% power conversion efficiency, J. H. Heo et al., Energ. Environ. Sci., 8, 602-1608 (2015); DOI: 10.1039/C5EE00120J.
  2. A [2,2]paracyclophane triarylamine-based hole-transporting material for high performance perovskite solar cells, S Park et al., J. Mater. Chem. A., 3, 24215-24220 (2015); DOI: 10.1039/C5TA08417B.
  3. Enhanced optopelectronic quality of perovskite thin films with hydrophosphorous acid for planar heterojunction solar cells, W. Zhang et al., Nat. Commun.,  6,  10030 (2015);  doi:10.1038/ncomms10030.

Methyl-ammonium iodide (MAI) chemical structure
Methylammonium Iodide (MAI) chemical structure
Methylammonium iodide (MAI) photo
Methylammonium Iodide (MAI) powder

Specifications

Chemical formulaCH6IN
SynonymsMethylamine hydroiodide
CAS No.14965-49-2
Chemical nameMethylammonium iodide
Physical appearanceWhite, crystalline solid
Purification methodRecrystallisation (ethanol)
Purity>99.9% (as measured by elemental analysis)
Molecular weight158.97 g/mol
Recommended solvents for perovskite synthesisDMF, DMSO

NMR spectrum

MAI 1H-NMR spectrum
1H NMR spectrum of methylammonium iodide in DMSO (500 MHz). The peaks centred around 2.5 and 3.3 ppm are residual DMSO and water impurities respectively from the deuterated NMR solvent. Click the image for a larger version.

Usage details

Reference devices - perovskite PVs

Reference devices were made to assess the performance of perovskite (MAI:PbCl2) based devices with the below structure. These were fabricated in air prior to spincasting the fullerene layer in a N2 glove box. Substrates were then transferred to a vacuum chamber where a composite metal cathode was thermally evaporated. Finally, substrates were encapsulated inside the glove box before measurements were taken under ambient conditions.

Glass / ITO (100 nm) / PEDOT:PSS (30 nm) / MAI:PbCl2 / PC70BM / Ca (5 nm) / Al (100 nm)

For generic details please see the fabrication guide and video. For specific details please see the below condensed fabrication report which details the optical modelling and optimisation of the multilayer stack.

The perovskite solution (MAI:PbCl2 at a molar ratio of 3:1) was made in dimethylformamide (DMF) at a concentration of 664 mg/ml. It was found to be critical that both materials were mixed dry prior to adding the solvent in order to achieve such high concentration.

For maximum efficiency, the active layer thickness was achieved from spincasting the heated solution (70°C) onto a hot PEDOT:PSS substrate (90°C) at a spin speed of 5000 rpm for 30s. The films were then placed back onto the hotplate (90°C) for 2 hrs. The data below shows the maximum performance achieved from non-optimised conditions.

Overall, the average efficiency after 5 mins light soaking was 8.89% (9.57% maximum) from MAI:PbCl2 based devices. Hysteresis was observed to be quite significant, with sweeps running from positive to negative bias presenting the best efficiencies (hereby referred to as reverse sweeps).

I101 perovskite ink J-V curve
Figure 1: JV curve under AM1.5 irradiation for a PV device based on MAI perovskite ink. Device characteristics were recorded on a reverse sweep.
I101 perovskite ink efficiency histogram
Figure 2: distribution in device efficiencies recorded for a typical process run. Data taken from 5 substrates containing 30 pixels. 10 pixels having low operational efficiency resulting from their proximity to the edge of the device substrate were removed from this analysis.

Fabrication

Substrates and cleaning

  • Pixelated Cathode substrates (S171) or Photovoltaic (8 Pixel) Substrates
  • 5 minutes sonication in hot 1% Hellmanex III
  • 1x boiling DI dump rinse, 1x cold dump rinse
  • 5 minutes sonication in warm IPA
  • 2x DI cold dump rinse
  • Stored in DI for 1hr
  • 5 minutes sonication in hot 10% NaOH solution
  • 2x DI dump rinse
  • N2 blow dry

PEDOT:PSS

  • PEDOT:PSS (Ossila M121 AI4083) filtered through a 0.45 µm PES filter (C2009S1)
  • Spin on heated substrates at 6000 rpm for 30s
  • Bake at 130°C after spincast
  • Note that the cathode strip was not wiped clean, this is to allow a consistent perovskite layer on top
  • Substrates held at a temperature of 90°C for spincasting

Active layer solution

  • Old stock solution (2 weeks old) of MAI:PbCl2 (3:1 molar ratio) made at a concentration 664 mg/ml in DMF
    • Heated for approx. 3 hrs at 70°C
  • Old stock solution of PC70BM, 50 mg/ml in CB
    • Heated for approx. 4 hrs at 70°C with stirbar

Active layers

  • Devices spun onto hot substrate at 5000 rpm using 25 µl dynamic dispense for 30s
  • Placed immediately onto hotplate at 90°C for 2 hrs
  • Cathode wipe with dry cotton bud once all substrates were spun
  • Films started with a bright yellow colour
  • Changed to a dark grey colour during thermal annealing process
  • Transferred to a N2 glove box
  • PCBM layer was spun at 1000 rpm for 30s, 20 µl dynamic dispense
  • CB cathode wipe

Evaporation

Left in vacuum chamber overnight and evaporated with the below parameters.

  • 5 nm Ca at 0.2 Å/s
  • 100 nm Al at 1.5 Å/s
  • Deposition pressure <1e-6 mbar="" li="">

Encapsulation

  • As standard using Ossila EE1, 30 mins UV in MEGA LV101

Measurements

  • JV sweeps taken with Keithley 237 source-meter
  • Illumination by Newport Oriel 9225-1000 solar simulator with 100 mW/cm2 AM1.5 output
  • NREL certified silicon reference cell used to calibrate
  • Lamp current: 7.8 A
  • Solar output at start of testing: 1.00 suns at 23°C
  • Solar output at end of testing: 1.00 suns at 25°C
  • Air cooled substrates
  • Room temperature at start of testing : 25°C
  • Room temperature at end of testing: 25°C
  • Calibrated aperture mask size: 0.256 mm2

We are continuously studying MAI and perovskites and expect to provide you with further information and optimised fabrication guides as we do so. Check back regularly or subscribe to our email newsletter for updates. In the meantime, please contact us if you have any further questions.

MSDS Documentation

Methylammonium iodide MSDSMethylammonium iodide MSDS sheet

Pricing

 GradeOrder CodeQuantityPrice
98% purityM27210 g£99.00
98% purityM27225 g£199.00
98% purityM272100 g£578.00
98% purityM272500 g£1740.00
>99.9% purityM2715 g£111.00
>99.9% purityM27110 g£179.00
>99.9% purityM27125 g£356.00

Note: Looking for a bulk order (100 g or above of 98% or greater purity)? Please contact us for a quote.


To the best of our knowledge the technical information provided here is accurate. However, Ossila assume no liability for the accuracy of this information. The values provided here are typical at the time of manufacture and may vary over time and from batch to batch.

蚂蚁淘电商平台
ebiomall.com
公司介绍
公司简介
蚂蚁淘(www.ebiomall.cn)是中国大陆目前唯一的生物医疗科研用品B2B跨境交易平台, 该平台由多位经验丰富的生物人和IT人负责运营。蚂蚁淘B2B模式是指客户有采购意向后在蚂蚁 淘搜索全球供应信息,找到合适的产品后在蚂蚁淘下单,然后蚂蚁淘的海外买手进行跨境采购、 运输到中国口岸,最后由蚂蚁淘国内团队报关运输给客户...
蚂蚁淘承诺
正品保证: 全球直采 在线追溯 蚂蚁淘所有产品都是自运营的,我们已经跟国外多家厂方建立品牌推广合作关系, 获得对方的支持和授权; 同时客户可以通过订单详情查看到货物从厂方至客户的所有流程, 确保货物的来源; 正规报关,提供13%增值税发票。
及时交付: 限时必达 畅选无忧 蚂蚁淘的运营团队都是有着多年经验的成员,他们熟悉海外采购、仓储物流、报关等环节; 同时通过在线的流程监控,蚂蚁淘的进口速度比传统企业提高了50%以上, 部分产品甚至能做到7-10天到货,即蚂蚁淘的“时必达”服务。
轻松采购: 在线下单 简单省事 蚂蚁淘的价格是真实透明的,并且具有很大的价格优势,不需要繁杂的询价比价; 报价单与合同可以直接在线生成或打印;就像在京东购物一样, 您的鼠标点击几 次即完成在蚂蚁淘的采购,订单详情会告诉您所有进程。
售后申请: 耐心讲解 优质服务 蚂蚁淘提供的产品在使用过程中如因产品质量问题有售后需求时, 您可通过我的订单提交您的“申请售后”, 蚂蚁淘产品顾问会第一时间为您处理, 在售后服务过程中如遇到问题也可致电蚂蚁淘客服热线:4000-520-616。
济南兰光机电技术有限公司在发布的聚丙烯药用滴眼剂瓶水蒸气渗透性检测仪供应信息,浏览与聚丙烯药用滴眼剂瓶水蒸气渗透性检测仪相关的产品或在搜索更多与聚丙烯药用滴眼剂瓶水蒸气渗透性检测仪相关的内容。 查看更多>
西安智诚生物科技有限公司在发布的优质分析纯 氯化钡 试剂 500g/瓶供应信息,浏览与优质分析纯 氯化钡 试剂 500g/瓶相关的产品或在搜索更多与优质分析纯 氯化钡 试剂 500g/瓶相关的内容。 查看更多>
沧州明洁药用包装有限公司在发布的1ml安瓿瓶供应信息,浏览与1ml安瓿瓶相关的产品或在搜索更多与1ml安瓿瓶相关的内容。 查看更多>
T500过滤盖三层培养瓶T500过滤盖三层培养瓶36496上海迪奥生物科技有限公司T500过滤盖三层培养瓶 查看更多>
prospenser瓶口分液器723053179808北京碧橙蓝生物科技有限责任公司prospenser瓶口分液器 查看更多>
上海优予生物科技有限公司在发布的Amine 75 cm2 Flask, 5/包, 10包/箱<br>透气斜颈培养瓶75 cm2 供应信息,浏览与Amine 75 cm2 Flask, 5/包, 10包/箱<br>透气斜颈培养瓶75 cm2 相关的产品或在搜索更多与Amine 75 cm2 Flask, 5/包, 10包/箱<br>透气斜颈培养瓶75 cm2 相关的内容。 查看更多>
月旭科技(上海)股份有限公司在发布的2ml透明样品瓶, 钳口, 带手写区供应信息,浏览与2ml透明样品瓶, 钳口, 带手写区相关的产品或在搜索更多与2ml透明样品瓶, 钳口, 带手写区相关的内容。 查看更多>
南通商友网络科技有限公司在发布的血清瓶供应信息,浏览与血清瓶相关的产品或在搜索更多与血清瓶相关的内容。 查看更多>
北京华瑞博远科技发展有限公司在发布的溶剂解析瓶 进样瓶 样品瓶供应信息,浏览与溶剂解析瓶 进样瓶 样品瓶相关的产品或在搜索更多与溶剂解析瓶 进样瓶 样品瓶相关的内容。 查看更多>
德国MieleG7826洗瓶机是由北京安麦格贸易有限公司代理或销售的Miele品牌的仪器,产品来源于德国。北京安麦格贸易有限公司是中国最权威的德国MieleG7826洗瓶机销售服务商之一,在北京等地方销售德国MieleG7826洗瓶机已经多年。同时,生物在线为您提供众多企业德国MieleG7826洗瓶机仪器产品及图片,以便挑选到性价比高,合适的德国MieleG7826洗瓶机产品 查看更多>
德国MielePG8528实验室洗瓶机是由北京安麦格贸易有限公司代理或销售的Miele品牌的仪器,产品来源于德国。北京安麦格贸易有限公司是中国最权威的德国MielePG8528实验室洗瓶机销售服务商之一,在北京等地方销售德国MielePG8528实验室洗瓶机已经多年。同时,生物在线为您提供众多企业德国MielePG8528实验室洗瓶机仪器产品及图片,以便挑选到性价比高,合适的德国MielePG8528实验室洗瓶机产品 查看更多>
陕西圣瑞医药科技有限公司在发布的药用级 冰醋酸 冰乙酸 国药准字 cp2010 500ml/瓶供应信息,浏览与药用级 冰醋酸 冰乙酸 国药准字 cp2010 500ml/瓶相关的产品或在搜索更多与药用级 冰醋酸 冰乙酸 国药准字 cp2010 500ml/瓶相关的内容。 查看更多>
常见问题
蚂蚁淘所售产品均为正品吗?
蚂蚁淘的创始人兼CEO是钟定松先生,具有十年的从业经验,在业界享有良好的口碑; Ebiomall是跨境直采平台,我们直接从厂家采购,自己的团队负责国际物流和清关,中间没有第三方,蚂蚁淘承诺所售产品仅为正品,假一罚十。
下单后可以修改订单吗?
未确认状态的订单可以修改,打开“订单详情”页面,点击右上角的“修改订单”即可,若已审核确定,则订单无法修改。
商品几天可以发货?
现货产品付款审核后即可发货,大部分期货产品在3周左右即可到货,提供时必达服务的产品订单审核十天内即可发货。
订单如何取消?
如订单处于未确定状态,进入“我的订单"页面,找到要取消的订单,点击“取消订单”按钮。
可以开发票吗?
本网站所售商品都是正规清关,均开具13%正规发票,发票金额含配送费金额,另有说明的除外。
如何联系商家?
蚂蚁淘任何页面都有在线咨询功能,点击“联系客服”、“咨询”或“在线咨询”按钮,均可咨询蚂蚁淘在线客服人员, 或拨打4000-520-616,除此之外客户可在 联系我们页面找到更多的联系方式。
收到的商品少了/发错了怎么办?
同个订单购买多个商品可能会分为一个以上包裹发出,可能不会同时送达,建议查看订单详情是否是部分发货状态;如未收到,可联系在线客服或者致电4000-520-616。
退换货/维修需要多长时间?
一般情况下,退货处理周期为客户收到产品一个月内(以快递公司显示签收时间为准),包装规格、数量、品种不符,外观毁损、短缺或缺陷,请在收到货24小时内申请退换货;特殊商品以合同条款为准。
商品咨询