Antigen Information
Assay Format
- PI3K-AKT Signaling
- Human
- Cell Culture Supernatants
- Cell Lysates
- Plasma
- Serum
- Tissue Lysates
- Sandwich-based
- Semi-Quantitative
Product Specifications
Product Features
- Easy to use
- No specialized equipment needed
- Compatible with nearly any liquid sample
- Proven technology (many publications)
- Highly sensitive (pg/ml)
- Sandwich ELISA specificity
- Higher density than ELISA, Western blot or bead-based multiplex
Target Names
Scroll over each target protein for more information | ||||
---|---|---|---|---|
ABL1
| ACK
| ALK-1
| Axl
| Blk
|
BMX
| Btk
| Csk
| Dtk
| EGFR
|
EphA1
| EphA2
| EphA3
| EphA4
| EphA5
|
EphA6
| EphA7
| EphA8
| EphB1
| EphB2
|
EphB3
| EphB4
| EphB6
| ErbB2
| ErbB3
|
ErbB4
| FAK
| FER
| FGFR1
| FGFR2
|
FGFR2 alpha isoform
| Fgr
| FRK
| Fyn
| Hck
|
HGFR
| IGF-1 R
| Insulin R(CD220)
| Itk
| JAK1
|
JAK2
| JAK3
| LCK
| LTK
| Lyn
|
MATK
| M-CSF R
| MUSK
| NGFR(TNFRSF16)
| PDGFRA
|
PDGFRB
| PYK2
| RET
| ROR1
| ROR2
|
ROS
| RYK
| SCF R(CD117/c-kit)
| SRMS
| SYK
|
Tec
| Tie-1
| Tie-2
| TNK1
| TRKB
|
TXK
| Tyk2
| TYRO10(DDR2/TKT)
| VEGFR2
| VEGFR3
|
ZAP70
|
Species Detected
Application Notes
- Human RTK Phosphorylation Antibody Array C1 Membranes
- Blocking Buffer
- Wash Buffer 1
- Wash Buffer 2
- Biotinylated Anti-Phospho Tyrosine Detection Antibody
- Streptavidin-Conjugated HRP
- Detection Buffer C
- Detection Buffer D
- Lysis Buffer (1 x 5 ml)
- Protease Inhibitor Cocktail
- Phosphatase Inhibitor Cocktail II
- 8-Well Incubation Tray
- Plastic Sheets
- Array Templates
- Manual
- Pipettors, pipet tips and other common lab consumables
- Orbital shaker or oscillating rocker
- Tissue Paper, blotting paper or chromatography paper
- Adhesive tape or Saran Wrap
- Distilled or de-ionized water
- A chemiluminescent blot documentation system (such as UVP??s ChemiDoc-It® or EpiChem II Benchtop Darkroom or GE"s ImageQuant™ LAS 4000 or Amersham Imagers 600 and 680), X-ray Film and a suitable film processor, or another chemiluminescent detection system.
- Block membranes
- Incubate with Sample
- Incubate with Biotinylated Detection Antibody Cocktail
- Incubate with HRP-Conjugated Streptavidin
- Incubate with Detection Buffers
- Image with chemiluminescent imaging system
- Perform densitometry and analysis
Storage/Stability
- Long, Zhi H., et al. "miR-141 inhibits proliferation and migration of colorectal cancer SW480 cells."?Anticancer research?37.8 (2017): 4345-4352.Species: HumanSample type: Cell Lysates
- Wang Z., Gao Q., Shi J., et al. Protein tyrosine phosphatase receptor S acts as a metastatic suppressor in hepatocellular carcinoma by control of epithermal growth factor receptor-induced epithelial-mesenchymal transition. Hepatology. 2015 Oct;62(4):1201-14. doi: 10.1002/hep.27911. Species: HumanSample type: Cell Lysate
- Cortelazzi B., Verderio P., Ciniselli CM., et al. Receptor tyrosine kinase profiles and human papillomavirus status in oropharyngeal squamous cell carcinoma.J Oral Pathol Med. 2014 Dec 14. doi: 10.1111/jop.12301. Epub ahead of printSpecies: HumanSample type: Tissue Lysate
- Acquired resistance to sunitinib in human renal cell carcinoma cells is mediated by constitutive activation of signal transduction pathways associated with tumour cell proliferationSpecies: HumanSample type: Conditioned Media
- Al-aidaroos A., et al. Metastasis-associated PRL-3 induces EGFR activation and addiction in cancer cells. J Clin Invest. 2013;123(8):3459-3471. doi:10.1172/JCI66824. Species: HumanSample type: Cell Lysate
- Siu IM., et al. Erlotinib Inhibits Growth of a Patient-Derived Chordoma Xenograft . Published: November 15, 2013 DOI: 10.1371/journal.pone.0078895Species: HumanSample type: Cell Lysate
- Guerra-Laso, JosÃ? M., et al. "Macrophages from elders are more permissive to intracellular multiplication of Mycobacterium tuberculosis."?Age?35.4 (2013): 1235-1250. Species: HumanSample type: Cell Lysate
- Tirado-GonzÃ?lez, I., et al. "Galectin-1 influences trophoblast immune evasion and emerges as a predictive factor for the outcome of pregnancy."?Molecular human reproduction?19.1 (2013): 43.Species: HumanSample type: Cell Lysate
- Strevens, Helena, et al. "PP038. Renal ETK/BMX activation decreased in preeclampsia."?Pregnancy Hypertension: An International Journal of Women's Cardiovascular Health?3.2 (2013): 80.Species: HumanSample type: Tissue Lysate
- Kato K., Gong J., Iwama H., et al. The antidiabetic drug metformin inhibits gastric cancer cell proliferation in vitro and in vivo. Mol Cancer Ther. 2012 Mar;11(3):549-60. doi: 10.1158/1535-7163.MCT-11-0594Species: HumanSample type: Cell Lysate
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
二个分度值的具体含义:
1.d是天平的最小刻度,称为分度值,也可叫作最小读数精度。按规定标准称其为天平实际标尺分度值,以符号“d”来代表。
2.e是天平检定标尺分度值,即检定时所用的分度值。检定时用的分度值和天平实际标尺分度值d不同,它不和d值一样是固定不变的,而是需要根据人为规定变化的值。可以规定e=5d,也可以规定e=10d,或者e=2d均可成立,只要不违反国家计量检定规程的规定就可以。
电子天平实际标尺分度值d是表示电子天平的最小精度是多少,检定标尺分度值e是电子天平进行检定时考核技术指标用的。准确的说,看电子天平的最佳精准度不能只看d值,还要看e值。特别是精确称量、科学实验及量值传递等部门在选择精密电子天平如0.01mg电子天平时最好要看检定标尺分度值e。
我公司新购进的一台梅特勒XUS205U的十万分之一天平,他可以进行十万分之一与万分之一的转换,d值0.01mg/0.1mg跟随工程师做了四角偏差,重复性的测试,关于最小称样量工程师拒绝给做。想请教各位有没有知道怎么做的。目前了解的就是用1g的砝码做标准偏差然后反推,但是还不是很清楚怎么做
我在预习天平的使用,这里不懂,谢谢
希望和大家分享这一点小小的经验。
我们公司想组建一个新的实验平台,仪器设备都得我们自己选,请问哪位有好点的分析天平(万一之一)推荐的,谢谢了。
保存在巴黎的国际计量局总部国际千克原器,在2007年的一次检查中,发现有118年历史、用铂和铱混合铸造的圆柱形铸件——国际千克原器减轻了大约50毫克。2013年1月初,德国最新一期《计量学》杂志刊载研究报告称,作为标准质量单位的国际千克原器因表面遭污染而略有增重。
由此联想到FDA不承认内置砝码校准的问题,内置砝没有处在“千克原器”的真空、恒温、恒湿的环境,一年四季温度、环境湿度处在不断变化过程,降温和环境湿度增加时,总会有水分子凝结在内置砝码表面。升温和环境湿度下降时,总会有吸附在FDA内置砝码上的水分子解吸附,内置砝码自身的质量本身就是不断波动的过程,这样理解FDA不承认内置砝码的校准是否正确。请明白的战友指正。
QC实验室的电子天平配有打印机,早已不是什么业界的新闻了。瑞士梅特勒-托利多公司的和德国赛多利斯等国际知名电子天平生产商在N年前(不夸张地说,20年前)就给电子天平配置了打印机,并且电子天平也可以和计算机相连接,将称量数据保存在计算机中。
我国的很多大药企和经过FDA、欧盟认证的药企,基本上都为电子天平配置了打印机和(或者)计算机,将称量数据及时打印出来,和(或者0将称量数据存储在计算机中。
电子天平配置打印机的目的是为了将打印数据及时打印出来,防止称量数据被丢失和人为的改动,或者称量数据不原始(有很多人习惯先将称量数据记录在本上或者纸上,然后在记录在正式的记录上,这也是符合TCH和cGMP的要求的。
我们为电子天平配置上打印机就能做到称量数据真实了吗?我说不一定。当然主流是操作人员会把称量数据及时真实地打印出来。非主流还是可以对称量数据可以做手脚的。为什么这样说?因为如果实验室没有LIMS系统,那么你的电子天平是独立的,操作也是独立的,没有被监视和控制。因为称量操作也会发生失败(比如称量结果超出称量范围或者称量完必,在称量物质转移时发生洒落等现象)。操作人员势必会重新进行称量,那么上次称量的数据就很可能被删除或者不打印出来。
另外,称量的时间也会被人为地改变。一是改变电子天平上的时间设置,二是改变打印机和(或者)计算机上的时间来做假。
所以,我们在给电子天平配置了打印机和(或者)计算机后,我们还应该有合适的文件或者LIMS系统设置和规定和操作人员、主管等人的权限,使我们的称量操作符合法规的要求。避免和减少差错的发生,是GMP的核心内容之一。
以上内容,仅供同行们参考,如有不妥,欢迎指正。因个人水平有限,写的内容会不全,欢迎朋友们进行补充,坛友们会感谢您的。
1251分析天平称重提到:电子分析天平有基于所用负载的内部校准系统。此校准适用于当前的环境温度。
<41>砝码与天平里面提到:2级砝码用于内置砝码的分析天平的校准工作,以及用于日常分析工作的实验室砝码。
但是看到一份培训资料,说美国fda不认可电子天平的自校系统的校验。
希望了解的战友执教,天平的自校和外置砝码校验是否都被fda接受。
谢谢