Due to high demand, the 5 micron constant interdigitated channel length test chips (S411) are currently out of stock. Please contact us for more details on the expected return date.
Ossila's new range of robust and reusable platinum test chips are designed to save you time and money.
The OFETs were patterned via photolithography, meaning very narrow channel lengths are acheivable.
The platinum is sputtered onto a titanium adhesion layer to provide an extremely robust contact and channel allowing it to withstand cleaning procedures such as solvent sonication, plasma etching, and swabbing. This allows the test chips to be reused multiple times for testing various materials saving a significant amount of time and money.
NOTE: Patterning using photolithography leaves exposed edges of the titanium adhesion layer. The consequence of this is that charge injection into the semiconducting layer can occur from the adhesion layer boundary instead of the platinum. Therefore these devices are recommend for single-crystal or single-flake materials that can sit on top of the electrode and span the electrode gap.
Mobility screening is made quick and simple with our prefabricated high density test chips, by depositing your semiconductor directly onto the surface you can create up to 20 OFETs on a single chip. In addition when using our high-density OFET test board you can test an entire chip in as little as 3 minutes reducing the overall time of both fabrication and measurement.
Productcode | Channelgeometry | Channelwidth | Channellength | Electrode pairs | Quantity | Price |
S403A1 | Linear | 1 mm | 2-10 μm Variable | 20 | 1 | £83 |
S403A2 | Linear | 1 mm | 4-10 μm Variable | 16 (minimum) | 1 | £50 |
S411 | Interdigitated | 26.6 mm | 5 μm | 20 | 1 | £83 |
User Manual
Specifications
Substrate / Gate | Silicon (p-doped) |
Gate dielectric | 300 nm thermally grown silicon dioxide |
Source-Drain electrodes | Platinum (100 nm) / Titanium adhesion layer (5 nm) |
Depostion method | Plasma sputtering |
Patterning method | Photolithography |
Applications
Ossila High Density Substrates feature up to 20 OFETs which can benefit your research in a number of ways. Firstly, production cost is reduced as a result of a higher volume of OFETs per substrate compared to the low density equivalents. This can help to stretch your budget to allow you to produce and test larger numbers of OFETs.
Secondly, producing OFETs is a far faster and less laborious process. Fabrication time is reduced by up to 50% when using prefabricated high density OFETs, freeing up more time to test the devices. As a result of this, greater volumes of statistics can be produced which in turn can provide more robust and reliable research.
Furthermore, OFET variability is reduced since a larger number of OFETs are produced with each fabrication. At Ossila we have optimised the fabrication process in order to produce consistently high quality substrates. In this respect, using our prefabricated substrates rather than fabricating your own can help you to gather more reliable data to benefit your research project.
Prefabricated high density substrates are ideal for mobility testing as they enable swift, efficient testing of high volumes of OFETs. The Ossila high-density OFET test board has been designed for this purpose.
Rather than using a mechanical probe station to test OFETs, which is a delicate and time-consuming process, the high density test board allows testing of multiple OFETs at one time; simply drop the substrate into the test slot, secure the push-fit lid and connect the board via its BNC connectors to an array of test equipment.
The board has been intelligently designed to reduce external noise, leakage current and stray capacitance in order to provide reliable and precise low-current testing.

Specifications
We fabricate our platinum test chips from p-doped silicon substrates. An insulating 300 nm silicon oxide gate dielectric is first grown on both sides of the silicon. The source and drain contacts consist of a 5 nm titanium adhesion layer below 100 nm of platinum. A platinum gate contact is also deposited along one edge of each substrate.
It is essential that there is an electrical connection between the gate contact and the p-doped silicon on the substrate sides. When the substrates are diced, a weak electrical connection is formed, however this can be easily removed when cleaning the substrate. We recommend applying silver (conductive) paint along and around the gate contact edge so that a more robust connection is made with the substrate edge.
For individual details and dimension drawings of each substrate type see below.
Linear variable channel length substrates (S403 & S404)
Geometry | Linear |
Arrangement (S403) | 20 electrode pairs, 5 channel widths |
Arrangement (S404) | 16 electrode pairs minimum, 4 channel widths minimum* |
Channel width | 1 mm |
Channel lengths | 2 (S403A1 only), 4, 6, 8, and 10 µm |

Interdigitated 22.6 mm x 5 µm constant channel length substrate (S411)
Geometry | Interdigitated |
Arrangement | 20 identical OFETs |
Channel width | 22.6 mm |
Channel length | 5 µm |

To the best of our knowledge the technical information provided here is accurate. However, Ossila assume no liability for the accuracy of this information. The values provided here are typical at the time of manufacture and may vary over time and from batch to batch.
ebiomall.com






>
>
>
>
>
>
>
>
>
>
>
>
中唐临界风险,33岁,第一胎,然后羊水穿刺加CMA基因芯片检查,染色体核型正常,4维彩超正常,医生说发育速度偏慢,但还算正常范围,CMA结果异常,如照片
无创dna检测8号染色体缺失32.99mb,羊穿正常,基因芯片检测还是8号染色体杂合性缺失32.2mb,请教专家孩子能要吗?万分感谢
求助各位大神,点击Downloadfulltable无法下载,总是出现错误,已经排除网络的问题,不知道是否还有其他方法下载,上面有一个Datatable的表格,不知道是不是芯片平台文件?
1、一张芯片上可以同时分析成百上千的探针,这样的情况可以检测多少位点?
2、基因芯片技术通量会有多大?怎么计算?
做蛋白质和microRNA的关系,那么先找出差异的蛋白质还是找出差异的microRNA好呢?有没有做ITRAQ和MICRORNA芯片好的公司推荐,非常感谢!
从GEO和ARRAYEXPRESS下载了miRNA的表达数据矩阵,但是结果不太一样,大致两种:①数值从个位数到几万不等,而且没有小数点;②数值在10上下,有小数点。见图
请问怎么知道数据是否经过了log转换?有注释文件说明吗?还是直接判断①是没转换的,②是转换的?
请问,我通过基因芯片筛选差异基因,有上调的也有下调的,即FC有正值,亦有负值,那么负值怎么取log?谢谢
研究蛋白质芯片的意义
1。蛋白质是基因表达的最终产物,接近生命活动的物质层面;
2。探针蛋白特异性高、亲和力强,可简化样品前处理,甚至可直接利用生物材料(血样、尿样、细胞及组织等)进行检测;
3。适合高通量筛选与靶蛋白作用的化合物;
4。有助于了解药物或毒物与其效应相关蛋白质的相互作用。
蛋白质芯片的分类:
1.蛋白质检测芯片
2.蛋白质功能芯片
蛋白质芯片的制备:
1。固相载体及其处理
载体(滴定板、滤膜、凝胶、载玻片)
2。蛋白质的预处理
选择具有较高纯度和完好生物活性的蛋白进行溶解
3。点制微阵列
可使用点制基因微阵列的商品化点样仪或喷墨法等
4。膜为载体:芯片放入湿盒,37°C1h
载玻片为载体:化学修饰产生醛基固定蛋白
5。微阵列的封闭固定微阵列上的蛋白样点
主要封闭试剂:BSA或Gly
相关链接:
全部有关生物芯片的实验方法技术(protocol)
生物芯片相关仪器及芯片・芯片扫描仪・芯片点样仪・生物芯片・生物芯片系统・其它
生物芯片技术服务
核酸分析类试剂
AFLP分析|SNP基因分型|线粒体DNA基因分型|其它基因分型|DNA指纹试剂盒|DNA测序试剂|核酸电泳凝胶|核酸标准品|凝胶纯化试剂盒|核酸染色|转座工具|其它